Logo AND Algorithmique Numérique Distribuée

Public GIT Repository
s/ *$// over all RST files (no content modification)
[simgrid.git] / docs / source / app_s4u.rst
index 5408491ea1675291ae293ce0dd4a9347d4bb8846..1395b79f3a919cd81c5c213521bb2d224d5d0b84 100644 (file)
@@ -396,7 +396,7 @@ Simulation objects
 
 
    .. group-tab:: Python
-   
+
       .. autoclass:: simgrid.Actor
 
 Basic management
@@ -790,7 +790,7 @@ Exiting
       .. doxygenclass:: simgrid::s4u::Engine
 
    .. group-tab:: Python
-   
+
       .. autoclass:: simgrid.Engine
 
 Engin initialization
@@ -976,7 +976,7 @@ Signals
       .. doxygenclass:: simgrid::s4u::Mailbox
 
    .. group-tab:: Python
-   
+
       .. autoclass:: simgrid.Mailbox
 
 Please also refer to the :ref:`full doc on s4u::Mailbox <s4u_mailbox>`.
@@ -1123,7 +1123,7 @@ Resources
       .. doxygenclass:: simgrid::s4u::Disk
 
    .. group-tab:: Python
-   
+
       .. autoclass:: simgrid.Disk
 
    .. group-tab:: C
@@ -1224,7 +1224,7 @@ Signals
       .. doxygenclass:: simgrid::s4u::Host
 
    .. group-tab:: Python
-   
+
       .. autoclass:: simgrid.Host
 
 Basic management
@@ -1395,9 +1395,13 @@ On/Off
       .. doxygenfunction:: sg_host_turn_off(sg_host_t host)
       .. doxygenfunction:: sg_host_turn_on(sg_host_t host)
 
+.. _API_s4u_Host_dvfs:
+
 DVFS
 ----
 
+See also the :ref:`relevant examples <s4u_ex_dvfs>`.
+
 .. tabs::
 
    .. group-tab:: C++
@@ -1468,7 +1472,7 @@ using :cpp:func:`Comm::sendto() <simgrid::s4u::Comm::sendto()>`.
 
       .. autoattribute:: simgrid.Host.netpoint
       .. automethod:: simgrid.Host.create_disk
-         
+
       .. automethod:: simgrid.Host.route_to
 
    .. group-tab:: C
@@ -1506,7 +1510,7 @@ Signals
 
 
    .. group-tab:: Python
-   
+
       .. autoclass:: simgrid.Link
 
 Basic management
@@ -1716,7 +1720,7 @@ Signals
       .. doxygenclass:: simgrid::s4u::NetZone
 
    .. group-tab:: Python
-   
+
       .. autoclass:: simgrid.NetZone
 
 Basic management
@@ -2148,7 +2152,7 @@ Signals
       .. doxygenclass:: simgrid::s4u::Comm
 
    .. group-tab:: Python
-   
+
       .. autoclass:: simgrid.Comm
 
 Basic management
@@ -2208,11 +2212,12 @@ Querying info
       .. automethod:: simgrid.Comm.set_payload_size
       .. automethod:: simgrid.Comm.set_rate
 
-Life cycle
-----------
+Direct host-to-host communication
+---------------------------------
 
 Most communications are created using :ref:`s4u_mailbox`, but you can
-also start direct communications as shown below.
+also start direct communications as shown below. See also the
+:ref:`relevant examples <s4u_ex_comm_host2host>`.
 
 .. tabs::
 
@@ -2223,6 +2228,19 @@ also start direct communications as shown below.
       .. doxygenfunction:: simgrid::s4u::Comm::sendto_init(Host *from, Host *to)
       .. doxygenfunction:: simgrid::s4u::Comm::sendto_async
 
+   .. group-tab:: Python
+
+      .. automethod:: simgrid.Comm.sendto
+      .. automethod:: simgrid.Comm.sendto_init
+      .. automethod:: simgrid.Comm.sendto_async
+
+Life cycle
+----------
+
+.. tabs::
+
+   .. group-tab:: C++
+
       .. doxygenfunction:: simgrid::s4u::Comm::cancel
       .. doxygenfunction:: simgrid::s4u::Comm::start
       .. doxygenfunction:: simgrid::s4u::Comm::test
@@ -2237,10 +2255,6 @@ also start direct communications as shown below.
 
    .. group-tab:: Python
 
-      .. automethod:: simgrid.Comm.sendto
-      .. automethod:: simgrid.Comm.sendto_init
-      .. automethod:: simgrid.Comm.sendto_async
-
       .. automethod:: simgrid.Comm.cancel
       .. automethod:: simgrid.Comm.start
       .. automethod:: simgrid.Comm.test
@@ -2285,7 +2299,7 @@ Signals
       .. doxygenclass:: simgrid::s4u::Exec
 
    .. group-tab:: Python
-   
+
       .. autoclass:: simgrid.Exec
 
 Basic management
@@ -2404,7 +2418,7 @@ Signals
       .. doxygenclass:: simgrid::s4u::Io
 
    .. group-tab:: Python
-   
+
       .. autoclass:: simgrid.Io
 
 Basic management
@@ -2751,6 +2765,55 @@ Locking
          .. doxygenfunction:: sg_sem_release(sg_sem_t sem)
          .. doxygenfunction:: sg_sem_would_block(const_sg_sem_t sem)
 
+===============
+Error reporting
+===============
+
+.. tabs::
+
+   .. group-tab:: C++
+
+      .. doxygenclass:: simgrid::Exception
+
+      The following exceptions denote a problem in the simulated platform, and it is often useful to catch them.
+
+      .. doxygenclass:: simgrid::CancelException
+      .. doxygenclass:: simgrid::HostFailureException
+      .. doxygenclass:: simgrid::NetworkFailureException
+      .. doxygenclass:: simgrid::StorageFailureException
+      .. doxygenclass:: simgrid::TimeoutException
+      .. doxygenclass:: simgrid::VmFailureException
+
+      The following errors denote a problem in the SimGrid tool itself. Most of the time, you should let these
+      exception go, so that the simulation stops. But you may want to catch them, for example when you launch
+      simgrid from a python notebook and want to handle the problem accordingly.
+
+      .. doxygenclass:: simgrid::AssertionError
+      .. doxygenclass:: simgrid::ParseError
+      .. doxygenclass:: simgrid::TracingError
+
+   .. group-tab:: Python
+
+      The following exceptions denote a problem in the simulated platform, and it is often useful to catch them.
+
+      .. autoclass:: simgrid.CancelException
+      .. autoclass:: simgrid.HostFailureException
+      .. autoclass:: simgrid.NetworkFailureException
+      .. autoclass:: simgrid.StorageFailureException
+      .. autoclass:: simgrid.TimeoutException
+      .. autoclass:: simgrid.VmFailureException
+
+      The following errors denote a problem in the SimGrid tool itself. Most of the time, you should let these
+      exception go, so that the simulation stops. But you may want to catch them, for example when you launch
+      simgrid from a python notebook and want to handle the problem accordingly.
+
+      .. autoclass:: simgrid.AssertionError
+
+   .. group-tab:: C
+
+      .. doxygenenum:: sg_error_t
+
+
 .. |hr| raw:: html
 
    <hr />