X-Git-Url: https://bilbo.iut-bm.univ-fcomte.fr/and/gitweb/LiCO.git/blobdiff_plain/014e854a02c1df7761fd67f873bc01a4d3fb204f..32b3267d56158c2c6b227fe08ec1b280fdde3606:/PeCO-EO/reponse2.tex diff --git a/PeCO-EO/reponse2.tex b/PeCO-EO/reponse2.tex index 7141bae..c695a98 100644 --- a/PeCO-EO/reponse2.tex +++ b/PeCO-EO/reponse2.tex @@ -41,7 +41,7 @@ by Ali Kadhum Idrees, Karine Deschinkel, Michel Salomon and Raph\"ael Couturier Dear Editor and Reviewers, -Comments (here in red color) raised by the reviewer n°1 after a first revision have been carefully considered. Please find below our answers highlighted in green. We did our best to satisfy your requests. +Comments (here in red color) raised by the reviewer n\textsuperscript{o}1 after a first revision have been carefully considered. Please find below our answers highlighted in green. We did our best to satisfy your requests. %Journal: Engineering Optimization %Reviewer's Comment to the Author Manuscript id GENO-2015-0094 @@ -55,7 +55,7 @@ Comments (here in red color) raised by the reviewer n°1 after a first revision -\noindent {\bf 3.} The communication and information sharing required to +\noindent {\textbf{3. \textsc{Reviewer's comment:} } } The communication and information sharing required to cooperate and make these decisions was not discussed.\\ \textcolor{blue}{\textbf{\textsc{Answer:} The communication and information @@ -65,9 +65,9 @@ cooperate and make these decisions was not discussed.\\ \textcolor{red}{\textbf{\textsc{Reviewer's response:} I see at the end of page 8 the description of the INFO packet. However, you are not including any description of the position coordinates, remaining energy, sensor node ID, etc. in the write up. I suggest adding this into the write up to make the communication clear.}}\\ -\textcolor{green}{\textbf{\textsc{Answer:} Right, we have included more description about the INFO packet and the ActiveSleep packet into the write up at the end of section~3.}}\\ +\textcolor{green}{\textbf{\textsc{Answer:} Right, we have included more description about the INFO packet and the ActiveSleep packet at the end of section~3.}}\\ -\noindent {\bf 7.} The methodology is implemented in OMNeT++ (network simulator) +\noindent {\textbf{7. \textsc{Reviewer's comment:}}} The methodology is implemented in OMNeT++ (network simulator) and tested against 2 existing algorithms and a previously developed method by the authors. The simulation results are thorough and show that the proposed method improves the coverage and network lifetime compared with the 3 existing @@ -86,13 +86,13 @@ about the way you formulated the problem. The mathematical optimization model is contribution but it's less convincing since the results are slightly better if not the same for the two methodologies you have developed. Could you include some other measure that shows that the PeCO is better? Maybe include computation time or something that is as convincing as the energy -consumed per sensor.}} +consumed per sensor.}}\\ \textcolor{green}{\textbf{\textsc{Answer:} In fact, we defined in section 5.1 a new performance metric linked to the energy, called Energy Saving Ratio (ESR). We added a new section (5.2.3) in the result part related to this performance metric which shows that our PeCO protocol provides better energy saving compared with other approaches.}}\\ -\noindent {\bf 8.} Since this paper is attacking the coverage problem, I would +\noindent {8. \textbf{\textsc{Reviewer's comment:}}} Since this paper is attacking the coverage problem, I would like to see more information on the amount of coverage the algorithm is achieving. It seems that there is a tradeoff in this algorithm that allows the network to increase its lifetime but does not improve the coverage ratio. This @@ -112,10 +112,9 @@ sentence though, "DiLCO is better for coverage ratios near $100\%$, but in that you would want to have a coverage ratio of $50\%$? This seems like a very small ratio and as you increase it, DiLCO becomes the methodology that has the maximum network lifetime. If you don't include application examples, your statement "Indeed there are applications that do not require a -100$\%$ coverage of the area to be monitored." stronger. }} +100$\%$ coverage of the area to be monitored." stronger. }}\\ -\textcolor{green}{\textbf{\textsc{Answer:} Thank you so much to your suggestion for adjusting the sentence in the end of Section 5.2.5. (previously Section 5.2.4.), It is done. -For the applications, we added some applications examples in the end of the sentence "Indeed there are applications that do not require a 100$\%$ coverage of the area to be monitored." as well as we changed the figure 10 (previously figure 9) by adding DilCO/70 and PecO/70 instead of DilCO/50 and PeCO/50 }}\\ +\textcolor{green}{\textbf{\textsc{Answer:} Thank you so much for your suggestion, we modified the sentence at the end of Section 5.2.5. (previously Section 5.2.4.). As recommended, we added some applications examples. We also changed the figure 10 (previously figure 9) by replacing DilCO/50 and PecO/50 by DilCO/70 and PeCO/70.}}\\