X-Git-Url: https://bilbo.iut-bm.univ-fcomte.fr/and/gitweb/canny.git/blobdiff_plain/01ec38902455e4ee4dba09ead751639638481fd2..dc91e8c17710cc249f83001625e1d14581f2d276:/experiments.tex?ds=sidebyside diff --git a/experiments.tex b/experiments.tex index 498e472..22900c0 100644 --- a/experiments.tex +++ b/experiments.tex @@ -62,80 +62,80 @@ this cover with respect to this embedding rate. -\subsection{Image quality}\label{sub:quality} -The visual quality of the STABYLO scheme is evaluated in this section. -For the sake of completeness, three metrics are computed in these experiments: -the Peak Signal to Noise Ratio (PSNR), -the PSNR-HVS-M family~\cite{psnrhvsm11}, -and -the weighted PSNR (wPSNR)~\cite{DBLP:conf/ih/PereiraVMMP01}. -The first one is widely used but does not take into -account the Human Visual System (HVS). -The other ones have been designed to tackle this problem. - -If we apply them on the running example with the Adaptive and STC strategies, -the PSNR, PSNR-HVS-M, and wPSNR values are respectively equal to -68.39, 79.85, and 89.71 for the stego Lena when $b$ is equal to 7. -If $b$ is 6, these values are respectively equal to -65.43, 77.2, and 89.35. - - - - -\begin{table*} -\begin{center} -\begin{small} -\setlength{\tabcolsep}{3pt} -\begin{tabular}{|c|c|c||c|c|c|c|c|c|c|c|c|c|} -\hline -Schemes & \multicolumn{4}{|c|}{STABYLO} & \multicolumn{2}{|c|}{HUGO}& \multicolumn{2}{|c|}{EAISLSBMR} & \multicolumn{2}{|c|}{WOW} & \multicolumn{2}{|c|}{UNIWARD}\\ -\hline -Embedding & Fixed & \multicolumn{3}{|c|}{Adaptive (about 6.35\%)} & Fixed &Adaptive & Fixed &Adaptive & Fixed &Adaptive & Fixed &Adaptive \\ -\hline -Rate & 10\% & + sample & +STC(7) & +STC(6) & 10\%&$\approx$6.35\%& 10\%&$\approx$6.35\%& 10\%&$\approx$6.35\%& 10\%&$\approx$6.35\%\\ -\hline -PSNR & 61.86 & 63.48 & 66.55 & 63.7 & 64.65 & {67.08} & 60.8 & 62.9&65.9 & 68.3 & 65.8 & 69.2\\ -\hline -PSNR-HVS-M & 72.9 & 75.39 & 78.6 & 75.5 & 76.67 & {79.6} & 71.8 & 76.0 & -76.7 & 80.35 & 77.6 & 81.2 \\ -\hline -wPSNR & 77.47 & 80.59 & 86.43& 86.28 & 83.03 & {88.6} & 76.7 & 83& 83.8 & 90.4 & 85.2 & 91.9\\ -\hline -\end{tabular} -\end{small} -\end{center} -\caption{Quality measures of steganography approaches\label{table:quality}} -\end{table*} - - - -Results are summarized in Table~\ref{table:quality}. -In this table, STC(7) stands for embedding data in the LSB whereas -in STC(6), data are hidden in the last two significant bits. - - -Let us give an interpretation of these experiments. -First of all, the Adaptive strategy produces images with lower distortion -than the images resulting from the 10\% fixed strategy. -Numerical results are indeed always greater for the former strategy than -for the latter one. -These results are not surprising since the Adaptive strategy aims at -embedding messages whose length is decided according to a higher threshold -into the edge detection. - - -If we combine Adaptive and STC strategies -the STABYLO scheme provides images whose quality is higher than -the EAISLSBMR's one but lower than the quality of high complexity -schemes. Notice that the quality of the less respectful scheme (EAILSBMR) -is lower than 6\% than the one of the most one. - - -% Let us now compare the STABYLO approach with other edge based steganography -% approaches, namely~\cite{DBLP:journals/eswa/ChenCL10,Chang20101286}. -% These two schemes focus on increasing the -% payload while the PSNR is acceptable, but do not -% give quality metrics for fixed embedding rates from a large base of images. +% \subsection{Image quality}\label{sub:quality} +% The visual quality of the STABYLO scheme is evaluated in this section. +% For the sake of completeness, three metrics are computed in these experiments: +% the Peak Signal to Noise Ratio (PSNR), +% the PSNR-HVS-M family~\cite{psnrhvsm11}, +% and +% the weighted PSNR (wPSNR)~\cite{DBLP:conf/ih/PereiraVMMP01}. +% The first one is widely used but does not take into +% account the Human Visual System (HVS). +% The other ones have been designed to tackle this problem. + +% If we apply them on the running example with the Adaptive and STC strategies, +% the PSNR, PSNR-HVS-M, and wPSNR values are respectively equal to +% 68.39, 79.85, and 89.71 for the stego Lena when $b$ is equal to 7. +% If $b$ is 6, these values are respectively equal to +% 65.43, 77.2, and 89.35. + + + + +% \begin{table*} +% \begin{center} +% \begin{small} +% \setlength{\tabcolsep}{3pt} +% \begin{tabular}{|c|c|c||c|c|c|c|c|c|c|c|c|c|} +% \hline +% Schemes & \multicolumn{4}{|c|}{STABYLO} & \multicolumn{2}{|c|}{HUGO}& \multicolumn{2}{|c|}{EAISLSBMR} & \multicolumn{2}{|c|}{WOW} & \multicolumn{2}{|c|}{UNIWARD}\\ +% \hline +% Embedding & Fixed & \multicolumn{3}{|c|}{Adaptive (about 6.35\%)} & Fixed &Adaptive & Fixed &Adaptive & Fixed &Adaptive & Fixed &Adaptive \\ +% \hline +% Rate & 10\% & + sample & +STC(7) & +STC(6) & 10\%&$\approx$6.35\%& 10\%&$\approx$6.35\%& 10\%&$\approx$6.35\%& 10\%&$\approx$6.35\%\\ +% \hline +% PSNR & 61.86 & 63.48 & 66.55 & 63.7 & 64.65 & {67.08} & 60.8 & 62.9&65.9 & 68.3 & 65.8 & 69.2\\ +% \hline +% PSNR-HVS-M & 72.9 & 75.39 & 78.6 & 75.5 & 76.67 & {79.6} & 71.8 & 76.0 & +% 76.7 & 80.35 & 77.6 & 81.2 \\ +% \hline +% wPSNR & 77.47 & 80.59 & 86.43& 86.28 & 83.03 & {88.6} & 76.7 & 83& 83.8 & 90.4 & 85.2 & 91.9\\ +% \hline +% \end{tabular} +% \end{small} +% \end{center} +% \caption{Quality measures of steganography approaches\label{table:quality}} +% \end{table*} + + + +% Results are summarized in Table~\ref{table:quality}. +% In this table, STC(7) stands for embedding data in the LSB whereas +% in STC(6), data are hidden in the last two significant bits. + + +% Let us give an interpretation of these experiments. +% First of all, the Adaptive strategy produces images with lower distortion +% than the images resulting from the 10\% fixed strategy. +% Numerical results are indeed always greater for the former strategy than +% for the latter one. +% These results are not surprising since the Adaptive strategy aims at +% embedding messages whose length is decided according to a higher threshold +% into the edge detection. + + +% If we combine Adaptive and STC strategies +% the STABYLO scheme provides images whose quality is higher than +% the EAISLSBMR's one but lower than the quality of high complexity +% schemes. Notice that the quality of the less respectful scheme (EAILSBMR) +% is lower than 6\% than the one of the most one. + + +% % Let us now compare the STABYLO approach with other edge based steganography +% % approaches, namely~\cite{DBLP:journals/eswa/ChenCL10,Chang20101286}. +% % These two schemes focus on increasing the +% % payload while the PSNR is acceptable, but do not +% % give quality metrics for fixed embedding rates from a large base of images. @@ -205,10 +205,10 @@ as far as we know. However by combining Adaptive and STC strategies our approach obtains similar results than the ones of these schemes. -Compared to EAILSBMR, we obtain better results when the strategy is +Compared to EAILSBMR, we obtain similar +results when the strategy is Adaptive. -However due to its -huge number of integration features, it is not lightweight. +However due to its huge number of integration features, it is not lightweight. All these numerical experiments confirm the objective presented in the motivations: