-\documentclass[12pt]{article}
+
+\documentclass[10pt, conference, compsocconf]{IEEEtran}
%\usepackage{latex8}
%\usepackage{times}
-\usepackage[latin1]{inputenc}
-\usepackage[cyr]{aeguill}
+\usepackage[utf8]{inputenc}
+%\usepackage[cyr]{aeguill}
%\usepackage{pstricks,pst-node,pst-text,pst-3d}
%\usepackage{babel}
\usepackage{amsmath}
\newcommand{\tab}{\ \ \ }
-%%%%%%%%%%%%%%%%%%%%%%%%%%%% my bib path.
+
+
+\begin{document}
+
+
+%% \author{\IEEEauthorblockN{Authors Name/s per 1st Affiliation (Author)}
+%% \IEEEauthorblockA{line 1 (of Affiliation): dept. name of organization\\
+%% line 2: name of organization, acronyms acceptable\\
+%% line 3: City, Country\\
+%% line 4: Email: name@xyz.com}
+%% \and
+%% \IEEEauthorblockN{Authors Name/s per 2nd Affiliation (Author)}
+%% \IEEEauthorblockA{line 1 (of Affiliation): dept. name of organization\\
+%% line 2: name of organization, acronyms acceptable\\
+%% line 3: City, Country\\
+%% line 4: Email: name@xyz.com}
+%% }
+
\title{Using FPGAs for high speed and real time cantilever deflection estimation}
+\author{\IEEEauthorblockN{Raphaël Couturier\IEEEauthorrefmark{1}, Stéphane Domas\IEEEauthorrefmark{1}, Gwenhaël Goavec-Merou\IEEEauthorrefmark{2} and Michel Lenczner\IEEEauthorrefmark{2}}
+\IEEEauthorblockA{\IEEEauthorrefmark{1}FEMTO-ST, DISC, University of Franche-Comte, Belfort, France\\
+\{raphael.couturier,stephane.domas\}@univ-fcomte.fr}
+\IEEEauthorblockA{\IEEEauthorrefmark{2}FEMTO-ST, Time-Frequency, University of Franche-Comte, Besançon, France\\
+\{michel.lenczner@utbm.fr,gwenhael.goavec@trabucayre.com}
+}
+
+
-\author{ Raphaël COUTURIER\\
-Laboratoire d'Informatique
-de l'Universit\'e de Franche-Comt\'e, \\
-BP 527, \\
-90016~Belfort CEDEX, France\\
- \and Stéphane Domas\\
-Laboratoire d'Informatique
-de l'Universit\'e de Franche-Comt\'e, \\
-BP 527, \\
-90016~Belfort CEDEX, France\\
- \and Gwenhaël Goavec\\
-??
-?? \\
-??, \\
-??\\}
-\begin{document}
\maketitle
\section{Introduction}
-%% blabla +
+Cantilevers are used inside atomic force microscope which provides high
+resolution images of surfaces. Several technics have been used to measure the
+displacement of cantilevers in litterature. For example, it is possible to
+determine accurately the deflection with different mechanisms.
+In~\cite{CantiPiezzo01}, authors used piezoresistor integrated into the
+cantilever. Nevertheless this approach suffers from the complexity of the
+microfabrication process needed to implement the sensor in the cantilever.
+In~\cite{CantiCapacitive03}, authors have presented an cantilever mechanism
+based on capacitive sensing. This kind of technic also involves to instrument
+the cantiliver which result in a complex fabrication process.
+
+In this paper our attention is focused on a method based on interferometry to
+measure cantilevers' displacements. In this method cantilevers are illuminated
+by an optic source. The interferometry produces fringes on each cantilevers
+which enables to compute the cantilever displacement. In order to analyze the
+fringes a high speed camera is used. Images need to be processed quickly and
+then a estimation method is required to determine the displacement of each
+cantilever. In~\cite{AFMCSEM11}, the authors have used an algorithm based on
+spline to estimate the cantilevers' positions.
+%%RAPH : ce qui est génant c'est qu'ils ne parlent pas de spline dans ce papier...
+ The overall process gives
+accurate results but all the computation are performed on a standard computer
+using labview. Consequently, the main drawback of this implementation is that
+the computer is a bootleneck in the overall process. In this paper we propose to
+use a method based on least square and to implement all the computation on a
+FGPA.
+
+The remainder of the paper is organized as follows. Section~\ref{sec:measure}
+describes more precisely the measurement process. Our solution based on the
+least square method and the implementation on FPGA is presented in
+Section~\ref{sec:solus}. Experimentations are described in
+Section~\ref{sec:results}. Finally a conclusion and some perspectives are
+presented.
+
+
+
%% quelques ref commentées sur les calculs basés sur l'interférométrie
\section{Measurement principles}
\label{sec:measure}
+In order to develop simple, cost effective and user-friendly probe arrays,
+authors of ~\cite{AFMCSEM11} have developped a system based of interferometry.
+
+
\subsection{Architecture}
\label{sec:archi}
%% description de l'architecture générale de l'acquisition d'images
$1024\times 1204$ pixels seems the minimum that can be reached. For a
$10\times 10$ cantilever array, if we neglect the time to extract
pixels, it implies that computing the deflection of a single
-cantilever should take less than 25$µ$s, thus 12.5$µ$s by phase.\\
+cantilever should take less than 25$\mu$s, thus 12.5$\mu$s by phase.\\
In fact, this timing is a very hard constraint. Let consider a very
small programm that initializes twenty million of doubles in memory
%% to be continued ...
-%% à faire : timing de l'algo spline en C avec atan et tout le bordel.
+%% � faire : timing de l'algo spline en C avec atan et tout le bordel.
\subsubsection{Comparison}
-\subsection{VDHL design paradigms}
+\subsection{VHDL design paradigms}
-\subsection{VDHL implementation}
+\subsection{VHDL implementation}
\section{Experimental results}
\label{sec:results}