]> AND Private Git Repository - dmems12.git/commitdiff
Logo AND Algorithmique Numérique Distribuée

Private GIT Repository
ajout biblio
authorcouturie <couturie@carcariass.(none)>
Sat, 15 Oct 2011 18:41:34 +0000 (20:41 +0200)
committercouturie <couturie@carcariass.(none)>
Sat, 15 Oct 2011 18:41:34 +0000 (20:41 +0200)
biblio.bib [new file with mode: 0644]
dmems12.tex

diff --git a/biblio.bib b/biblio.bib
new file mode 100644 (file)
index 0000000..c392b6d
--- /dev/null
@@ -0,0 +1,39 @@
+
+
+
+@Article{CantiCapacitive03,
+       author =                         {D. R. Baselt and B. Fruhberger and E. Klaassen and S. Cemalovic and C. L. Britton and S. V. Patel and T. E. Mlsna and D. McCorkle and B. Warmack},
+       title =                          {Design and performance of a microcantilever-based hydrogen sensor},
+       journal =                {Sensors and Actuators B: Chemical},
+       year =                           {2003},
+       volume =         {88},
+       number =         {2},
+       pages =                  {120--131},
+       month =                  {Jan},
+}
+
+
+
+
+@Article{CantiPiezzo01,
+       author =                         {N. Abedinov and P. Grabiec and T. Gotszalk and T. Ivanov and J. Voigt and I. W. Rangelow},
+       title =                          {Micromachined piezoresistive cantilever array with integrated resistive microheater for calorimetry and mass detection},
+       journal =                {Journal of Vacuum Science and Technology A},
+       year =                           {2001},
+       volume =         {19},
+       number =         {6},
+       pages =                  {2884–2888},
+       month =                  {Nov},
+}
+
+
+@Article{CantiOptic89,
+       author =                         {D. Rugar and H. J. Mamin and P. Guethner},
+       title =                          {Improved fiber-optic interferometer for atomic force microscopy},
+       journal =                {Appl. Phys. Lett.},
+       year =                           {1989},
+       volume =         {55},
+       number =         {25},
+       pages =                  {2588--2590},
+
+}
index 423b0f73d85906ffe39519a5b5b1e254a0e19fe1..a51313754361ffae82edc743e810be54fcb52a3e 100644 (file)
 
 \section{Introduction}
 
 
 \section{Introduction}
 
+Cantilevers  are  used  inside  atomic  force  microscope  which  provides  high
+resolution images of  surfaces.  Several technics have been  used to measure the
+displacement  of cantilevers  in litterature.   For example,  it is  possible to
+determine  accurately   the  deflection  with   optic  interferometer~\cite{CantiOptic89},
+pizeoresistor~\cite{CantiPiezzo01}                 or                 capacitive
+sensing~\cite{CantiCapacitive03}.
 %% blabla +
 %% quelques ref commentées sur les calculs basés sur l'interférométrie
 
 %% blabla +
 %% quelques ref commentées sur les calculs basés sur l'interférométrie