@@ -90,16 +90,16 @@ execution  time of  an application  running on  that processor.   Therefore, the
 frequency that  gives the best trade-off  between the energy  consumption and the
 performance of an application must be selected.
 
-In this  paper, a new  online frequency selecting algorithm  for heterogeneous
-platforms is presented.   It selects the frequencies and tries  to give the best
-trade-off  between  energy saving  and  performance  degradation,  for each  node
-computing the message  passing iterative application. The algorithm  has a small
+In this paper, a new online frequency selecting algorithm for heterogeneous
+platforms is presented.  It selects the frequencies and tries to give the best
+trade-off between energy saving and performance degradation, for each node
+computing the message passing iterative application. The algorithm has a small
 overhead and works without training or profiling. It uses a new energy model for
-message passing iterative applications  running on a heterogeneous platform. The
-proposed algorithm is  evaluated on the SimGrid simulator  while running the NAS
-parallel  benchmarks.  The  experiments   show  that  it  reduces  the  energy
-consumption by up to 35\% while  limiting the performance degradation as much as
-possible.   Finally,  the algorithm  is  compared  to  an existing  method,  the
+message passing iterative applications running on a heterogeneous platform. The
+proposed algorithm is evaluated on the SimGrid simulator while running the NAS
+parallel benchmarks.  The experiments show that it reduces the energy
+consumption by up to \np[\%]{35} while limiting the performance degradation as
+much as possible.  Finally, the algorithm is compared to an existing method, the
 comparison results showing that it outperforms the latter.
 
 \end{abstract}
@@ -207,30 +207,35 @@ consumption of this type of platform.  Naveen et
 al.~\cite{Naveen_Power.Efficient.Resource.Scaling} developed a method that
 minimizes the value of $\mathit{energy}\times \mathit{delay}^2$ (the delay is
 the sum of slack times that happen during synchronous communications) by
-dynamically assigning new frequencies to the CPUs of the heterogeneous
-cluster. Lizhe et al.~\cite{Lizhe_Energy.aware.parallel.task.scheduling}
-proposed an algorithm that divides the executed tasks into two types: the
-critical and non critical tasks. The algorithm scales down the frequency of non
-critical tasks proportionally to their slack and communication times while
-limiting the performance degradation percentage to less than
-10\%. In~\cite{Joshi_Blackbox.prediction.of.impact.of.DVFS}, they developed a
+dynamically assigning new frequencies to the CPUs of the heterogeneous cluster.
+Lizhe et al.~\cite{Lizhe_Energy.aware.parallel.task.scheduling} proposed an
+algorithm that divides the executed tasks into two types: the critical and non
+critical tasks. The algorithm scales down the frequency of non critical tasks
+proportionally to their slack and communication times while limiting the
+performance degradation percentage to less than \np[\%]{10}.
+In~\cite{Joshi_Blackbox.prediction.of.impact.of.DVFS}, they developed a
 heterogeneous cluster composed of two types of Intel and AMD processors. They
 use a gradient method to predict the impact of DVFS operations on performance.
 In~\cite{Shelepov_Scheduling.on.Heterogeneous.Multicore} and
 \cite{Li_Minimizing.Energy.Consumption.for.Frame.Based.Tasks}, the best
 frequencies for a specified heterogeneous cluster are selected offline using
-some heuristic. Chen et
+some heuristic.  Chen et
 al.~\cite{Chen_DVFS.under.quality.of.service.requirements} used a greedy dynamic
 programming approach to minimize the power consumption of heterogeneous servers
-while respecting given time constraints. This approach had considerable
+while respecting given time constraints.  This approach had considerable
 overhead.  In contrast to the above described papers, this paper presents the
 following contributions :
 \begin{enumerate}
-\item  two new energy and performance models for message passing iterative synchronous applications running over 
-       a heterogeneous platform. Both models take into account  communication and slack times. The models can predict the required energy and the execution time of the application.
+\item two new energy and performance models for message passing iterative
+  synchronous applications running over a heterogeneous platform. Both models
+  take into account communication and slack times. The models can predict the
+  required energy and the execution time of the application.
        
-\item a new online frequency selecting algorithm for heterogeneous platforms. The algorithm has a very small 
-      overhead and does not need any training or profiling. It uses a new optimization function which simultaneously maximizes the performance and minimizes the energy consumption of a message passing iterative synchronous application.
+\item a new online frequency selecting algorithm for heterogeneous
+  platforms. The algorithm has a very small overhead and does not need any
+  training or profiling. It uses a new optimization function which
+  simultaneously maximizes the performance and minimizes the energy consumption
+  of a message passing iterative synchronous application.
       
 \end{enumerate}
 
@@ -722,26 +727,26 @@ scaling factors that gives the results of the next sections.
 
 \section{Experimental results}
 \label{sec.expe}
-To  evaluate the  efficiency and  the  overall energy  consumption reduction  of
+To evaluate the efficiency and the overall energy consumption reduction of
 Algorithm~\ref{HSA}, it was applied to the NAS parallel benchmarks NPB v3.3. The
-experiments were executed on the  simulator SimGrid/SMPI which offers easy tools
+experiments were executed on the simulator SimGrid/SMPI which offers easy tools
 to create a heterogeneous platform and run message passing applications over it.
-The heterogeneous  platform that was used  in the experiments, had  one core per
+The heterogeneous platform that was used in the experiments, had one core per
 node because just one process was executed per node.  The heterogeneous platform
-was  composed  of  four  types  of  nodes. Each  type  of  nodes  had  different
-characteristics  such as  the maximum  CPU  frequency, the  number of  available
-frequencies  and the  computational power,  see Table~\ref{table:platform}. The
-characteristics  of  these  different  types  of nodes  are  inspired  from  the
-specifications of real  Intel processors.  The heterogeneous platform  had up to
+was composed of four types of nodes. Each type of nodes had different
+characteristics such as the maximum CPU frequency, the number of available
+frequencies and the computational power, see Table~\ref{table:platform}. The
+characteristics of these different types of nodes are inspired from the
+specifications of real Intel processors.  The heterogeneous platform had up to
 144 nodes and had nodes from the four types in equal proportions, for example if
 a benchmark was executed on 8 nodes, 2 nodes from each type were used. Since the
-constructors of  CPUs do not specify the  dynamic and the static  power of their
-CPUs, for  each type of  node they were  chosen proportionally to  its computing
-power  (FLOPS).  In  the initial  heterogeneous platform,  while  computing with
-highest frequency,  each node  consumed an amount  of power proportional  to its
-computing  power  (which  corresponds to  80\%  of  its  dynamic power  and  the
-remaining  20\%  to  the  static   power),  the  same  assumption  was  made  in
-\cite{Our_first_paper,Rauber_Analytical.Modeling.for.Energy}.    Finally,  These
+constructors of CPUs do not specify the dynamic and the static power of their
+CPUs, for each type of node they were chosen proportionally to its computing
+power (FLOPS).  In the initial heterogeneous platform, while computing with
+highest frequency, each node consumed an amount of power proportional to its
+computing power (which corresponds to \np[\%]{80} of its dynamic power and the
+remaining \np[\%]{20} to the static power), the same assumption was made in
+\cite{Our_first_paper,Rauber_Analytical.Modeling.for.Energy}.  Finally, These
 nodes were connected via an Ethernet network with 1 Gbit/s bandwidth.
 
 
@@ -962,47 +967,47 @@ be executed on $1, 4, 9, 16, 36, 64, 144$ nodes.
   \end{tabular}
   \label{table:res_128n}
 \end{table}
-The overall energy  consumption was computed for each  instance according to the
-energy  consumption  model  (\ref{eq:energy}),  with and  without  applying  the
+The overall energy consumption was computed for each instance according to the
+energy consumption model (\ref{eq:energy}), with and without applying the
 algorithm. The execution time was also measured for all these experiments. Then,
 the energy saving and performance degradation percentages were computed for each
-instance.    The   results   are   presented  in   Tables~\ref{table:res_4n},
-\ref{table:res_8n},           \ref{table:res_16n},          \ref{table:res_32n},
+instance.  The results are presented in Tables~\ref{table:res_4n},
+\ref{table:res_8n}, \ref{table:res_16n}, \ref{table:res_32n},
 \ref{table:res_64n} and \ref{table:res_128n}. All these results are the average
-values  from many experiments  for energy  savings and  performance degradation.
+values from many experiments for energy savings and performance degradation.
 The tables show the experimental results for running the NAS parallel benchmarks
-on  different  number  of  nodes.   The  experiments  show  that  the  algorithm
-significantly reduces the energy consumption (up to 35\%) and tries to limit the
-performance  degradation.  They  also  show that  the  energy saving  percentage
-decreases when the  number of computing nodes increases.   This reduction is due
-to the increase of the communication  times compared to the execution times when
-the benchmarks are run over a high number of nodes.  Indeed, the benchmarks with
-the  same  class,  C,  are  executed  on different  numbers  of  nodes,  so  the
-computation required  for each iteration is  divided by the  number of computing
-nodes.  On the other hand,  more communications are required when increasing the
-number  of  nodes so  the  static energy  increases  linearly  according to  the
-communication time and the dynamic power  is less relevant in the overall energy
-consumption.   Therefore, reducing the  frequency with  Algorithm~\ref{HSA} is
-less effective  in reducing the overall  energy savings. It can  also be noticed
-that for the benchmarks EP and  SP that contain little or no communications, the
-energy savings are  not significantly affected by the high  number of nodes.  No
-experiments were conducted  using bigger classes than D,  because they require a
-lot  of memory (more  than 64GB)  when being  executed by  the simulator  on one
-machine.   The maximum  distance between  the  normalized energy  curve and  the
-normalized performance for each instance is  also shown in the result tables. It
-decrease in the same way as  the energy saving percentage.  The tables also show
-that the performance degradation  percentage is not significantly increased when
-the number  of computing  nodes is increased  because the computation  times are
-small when compared to the communication times.
+on different number of nodes.  The experiments show that the algorithm
+significantly reduces the energy consumption (up to \np[\%]{35}) and tries to
+limit the performance degradation.  They also show that the energy saving
+percentage decreases when the number of computing nodes increases.  This
+reduction is due to the increase of the communication times compared to the
+execution times when the benchmarks are run over a high number of nodes.
+Indeed, the benchmarks with the same class, C, are executed on different numbers
+of nodes, so the computation required for each iteration is divided by the
+number of computing nodes.  On the other hand, more communications are required
+when increasing the number of nodes so the static energy increases linearly
+according to the communication time and the dynamic power is less relevant in
+the overall energy consumption.  Therefore, reducing the frequency with
+Algorithm~\ref{HSA} is less effective in reducing the overall energy savings. It
+can also be noticed that for the benchmarks EP and SP that contain little or no
+communications, the energy savings are not significantly affected by the high
+number of nodes.  No experiments were conducted using bigger classes than D,
+because they require a lot of memory (more than 64GB) when being executed by the
+simulator on one machine.  The maximum distance between the normalized energy
+curve and the normalized performance for each instance is also shown in the
+result tables. It decrease in the same way as the energy saving percentage.  The
+tables also show that the performance degradation percentage is not
+significantly increased when the number of computing nodes is increased because
+the computation times are small when compared to the communication times.
 
 
  
 \begin{figure}[!t]
   \centering
-  \subfloat[Energy saving]{%
+  \subfloat[Energy saving (\%)]{%
     \includegraphics[width=.33\textwidth]{fig/energy}\label{fig:energy}}%
   
-  \subfloat[Performance degradation ]{%
+  \subfloat[Performance degradation (\%)]{%
     \includegraphics[width=.33\textwidth]{fig/per_deg}\label{fig:per_deg}}
   \label{fig:avg}
   \caption{The energy and performance for all NAS benchmarks running with a different number of nodes}
@@ -1027,59 +1032,61 @@ has less effect on the performance.
 
 \subsection{The results for different power consumption scenarios}
 \label{sec.compare}
-The results  of the previous section  were obtained while  using processors that
-consume during  computation an overall power  which is 80\%  composed of dynamic
-power and of 20\% of static power. In this section, these ratios are changed and
-two new  power scenarios are  considered in order  to evaluate how  the proposed
-algorithm adapts itself  according to the static and  dynamic power values.  The
-two new power scenarios are the following:
+The results of the previous section were obtained while using processors that
+consume during computation an overall power which is \np[\%]{80} composed of
+dynamic power and of \np[\%]{20} of static power. In this section, these ratios
+are changed and two new power scenarios are considered in order to evaluate how
+the proposed algorithm adapts itself according to the static and dynamic power
+values.  The two new power scenarios are the following:
 
 \begin{itemize}
-\item 70\% of dynamic power  and 30\% of static power
-\item 90\% of dynamic power  and 10\% of static power
+\item \np[\%]{70} of dynamic power and \np[\%]{30} of static power
+\item \np[\%]{90} of dynamic power and \np[\%]{10} of static power
 \end{itemize}
 
-The NAS parallel benchmarks were  executed again over processors that follow the
-new power scenarios.   The class C of each  benchmark was run over 8  or 9 nodes
-and   the    results   are   presented   in    Tables~\ref{table:res_s1}   and
-\ref{table:res_s2}. These tables  show that the energy saving  percentage of the
-70\%-30\% scenario is  smaller for all benchmarks compared  to the energy saving
-of the 90\%-10\% scenario. Indeed, in  the latter more dynamic power is consumed
-when  nodes are running  on their  maximum frequencies,  thus, scaling  down the
-frequency of  the nodes results in  higher energy savings than  in the 70\%-30\%
-scenario. On the  other hand, the performance degradation  percentage is smaller
-in the 70\%-30\% scenario compared to the 90\%-10\% scenario. This is due to the
-higher  static  power percentage  in  the first  scenario  which  makes it  more
-relevant in the  overall consumed energy.  Indeed, the  static energy is related
-to the execution time and if  the performance is degraded the amount of consumed
-static  energy directly  increases.  Therefore,  the proposed  algorithm  does not
-really significantly  scale down much the  frequencies of the nodes  in order to
-limit the  increase of the  execution time and  thus limiting the effect  of the
+The NAS parallel benchmarks were executed again over processors that follow the
+new power scenarios.  The class C of each benchmark was run over 8 or 9 nodes
+and the results are presented in Tables~\ref{table:res_s1} and
+\ref{table:res_s2}. These tables show that the energy saving percentage of the
+\np[\%]{70}-\np[\%]{30} scenario is smaller for all benchmarks compared to the
+energy saving of the \np[\%]{90}-\np[\%]{10} scenario.  Indeed, in the latter
+more dynamic power is consumed when nodes are running on their maximum
+frequencies, thus, scaling down the frequency of the nodes results in higher
+energy savings than in the \np[\%]{70}-\np[\%]{30} scenario. On the other hand,
+the performance degradation percentage is smaller in the \np[\%]{70}-\np[\%]{30}
+scenario compared to the \np[\%]{90}-\np[\%]{10} scenario. This is due to the
+higher static power percentage in the first scenario which makes it more
+relevant in the overall consumed energy.  Indeed, the static energy is related
+to the execution time and if the performance is degraded the amount of consumed
+static energy directly increases.  Therefore, the proposed algorithm does not
+really significantly scale down much the frequencies of the nodes in order to
+limit the increase of the execution time and thus limiting the effect of the
 consumed static energy.
 
-Both   new  power   scenarios   are  compared   to   the  old   one  in
-Figure~\ref{fig:sen_comp}. It  shows the average of the  performance degradation, the
-energy saving and the  distances for all NAS benchmarks of class  C running on 8
-or 9 nodes.   The comparison shows that the energy  saving ratio is proportional
-to the dynamic power ratio: it is increased when applying the 90\%-10\% scenario
-because at  maximum frequency  the dynamic  energy is the  most relevant  in the
-overall consumed  energy and can  be reduced by  lowering the frequency  of some
-processors. On  the other hand, the  energy saving decreases  when the 70\%-30\%
-scenario is  used because  the dynamic  energy is less  relevant in  the overall
-consumed energy and  lowering the frequency does not  return big energy savings.
-Moreover, the average  of the performance degradation is  decreased when using a
-higher  ratio   for  static  power  (e.g.   70\%-30\%   scenario  and  80\%-20\%
-scenario). Since  the proposed algorithm  optimizes the energy  consumption when
-using a  higher ratio for dynamic  power the algorithm  selects bigger frequency
-scaling  factors that result  in more  energy saving  but less  performance, for
-example see  Figure~\ref{fig:scales_comp}. The  opposite happens when  using a
-higher  ratio for  static power,  the algorithm  proportionally  selects smaller
-scaling  values which result  in less  energy saving  but also  less performance
+Both new power scenarios are compared to the old one in
+Figure~\ref{fig:sen_comp}. It shows the average of the performance degradation,
+the energy saving and the distances for all NAS benchmarks of class C running on
+8 or 9 nodes.  The comparison shows that the energy saving ratio is proportional
+to the dynamic power ratio: it is increased when applying the
+\np[\%]{90}-\np[\%]{10} scenario because at maximum frequency the dynamic energy
+is the most relevant in the overall consumed energy and can be reduced by
+lowering the frequency of some processors. On the other hand, the energy saving
+decreases when the \np[\%]{70}-\np[\%]{30} scenario is used because the dynamic
+energy is less relevant in the overall consumed energy and lowering the
+frequency does not return big energy savings.  Moreover, the average of the
+performance degradation is decreased when using a higher ratio for static power
+(e.g.  \np[\%]{70}-\np[\%]{30} scenario and \np[\%]{80}-\np[\%]{20}
+scenario). Since the proposed algorithm optimizes the energy consumption when
+using a higher ratio for dynamic power the algorithm selects bigger frequency
+scaling factors that result in more energy saving but less performance, for
+example see Figure~\ref{fig:scales_comp}. The opposite happens when using a
+higher ratio for static power, the algorithm proportionally selects smaller
+scaling values which result in less energy saving but also less performance
 degradation.
 
 
  \begin{table}[!t]
-  \caption{The results of the 70\%-30\% power scenario}
+  \caption{The results of the \np[\%]{70}-\np[\%]{30} power scenario}
   % title of Table
   \centering
   \begin{tabular}{|*{6}{r|}}
@@ -1108,7 +1115,7 @@ degradation.
 
 
 \begin{table}[!t]
-  \caption{The results of the 90\%-10\% power scenario}
+  \caption{The results of the \np[\%]{90}-\np[\%]{10} power scenario}
   % title of Table
   \centering
   \begin{tabular}{|*{6}{r|}}
@@ -1195,9 +1202,10 @@ efficiency. Table~\ref{table:compare_EDP} presents the results of comparing the
 execution times and the energy consumption for both versions of the NAS
 benchmarks while running the class C of each benchmark over 8 or 9 heterogeneous
 nodes. The results show that our algorithm provides better energy savings than
-Spiliopoulos et al. algorithm, on average it results in 29.76\% energy saving
-while their algorithm returns just 25.75\%. The average of performance
-degradation percentage is approximately the same for both algorithms, about 4\%.
+Spiliopoulos et al. algorithm, on average it results in \np[\%]{29.76} energy
+saving while their algorithm returns just \np[\%]{25.75}. The average of
+performance degradation percentage is approximately the same for both
+algorithms, about \np[\%]{4}.
 
 
 For all benchmarks,  our algorithm outperforms Spiliopoulos et  al. algorithm in
@@ -1209,20 +1217,20 @@ degradation values while giving the same weight for both metrics.
 \section{Conclusion}
 \label{sec.concl} 
 In this paper, a new online frequency selecting algorithm has been presented. It
-selects the  best possible  vector of frequency  scaling factors that  gives the
-maximum  distance  (optimal  trade-off)  between  the predicted  energy  and  the
+selects the best possible vector of frequency scaling factors that gives the
+maximum distance (optimal trade-off) between the predicted energy and the
 predicted performance curves for a heterogeneous platform. This algorithm uses a
-new  energy  model  for  measuring  and predicting  the  energy  of  distributed
-iterative  applications running  over heterogeneous  platforms. To  evaluate the
+new energy model for measuring and predicting the energy of distributed
+iterative applications running over heterogeneous platforms. To evaluate the
 proposed method, it was applied on the NAS parallel benchmarks and executed over
-a heterogeneous  platform simulated by  SimGrid. The results of  the experiments
-showed that the algorithm reduces up to 35\% the energy consumption of a message
-passing iterative method while limiting  the degradation of the performance. The
-algorithm also selects different scaling  factors according to the percentage of
-the computing and communication times, and according to the values of the static
-and  dynamic  powers  of the  CPUs.   Finally,  the  algorithm was  compared  to
-Spiliopoulos et al.  algorithm and  the results showed that it outperforms their
-algorithm in terms of energy-time trade-off.
+a heterogeneous platform simulated by SimGrid. The results of the experiments
+showed that the algorithm reduces up to \np[\%]{35} the energy consumption of a
+message passing iterative method while limiting the degradation of the
+performance. The algorithm also selects different scaling factors according to
+the percentage of the computing and communication times, and according to the
+values of the static and dynamic powers of the CPUs.  Finally, the algorithm was
+compared to Spiliopoulos et al.  algorithm and the results showed that it
+outperforms their algorithm in terms of energy-time trade-off.
 
 In the near future, this method  will be applied to real heterogeneous platforms
 to evaluate its  performance in a real study case. It  would also be interesting