]> AND Private Git Repository - mpi-energy2.git/blobdiff - mpi-energy2-extension/Heter_paper.tex
Logo AND Algorithmique Numérique Distribuée

Private GIT Repository
correcting the last paragraph
[mpi-energy2.git] / mpi-energy2-extension / Heter_paper.tex
index e30d62cdb03dbe5f6b62ecc1975f51d67eadee73..09061339d3811524f420617c4b8318cb95b838cb 100644 (file)
@@ -54,7 +54,7 @@
 \newcommand{\Sopt}[1][]{\Xsub{S}{opt}_{#1}}
 \newcommand{\Tcm}[1][]{\Xsub{T}{cm}_{\fxheight{#1}}}
 \newcommand{\Tcp}[1][]{\Xsub{T}{cp}_{#1}}
-\newcommand{\Pmax}[1][]{\Xsub{P}{max}_{#1}}
+\newcommand{\Pmax}[1][]{\Xsub{P}{max}_{\fxheight{#1}}}
 \newcommand{\Pidle}[1][]{\Xsub{P}{idle}_{\fxheight{#1}}}
 \newcommand{\TcpOld}[1][]{\Xsub{T}{cpOld}_{#1}}
 \newcommand{\Tnew}{\Xsub{T}{New}}
@@ -567,7 +567,7 @@ maximum distance between the energy curve and the performance curve is, which re
 
 \section{Experimental results}
 \label{sec.expe}
-While in~\cite{pdsec2015} the energy  model and the scaling factors selection algorithm were applied to a heterogeneous cluster and  evaluated over the SimGrid simulator~\cite{SimGrid.org}, 
+While in~\cite{pdsec2015} the energy  model and the scaling factors selection algorithm were applied to a heterogeneous cluster and  evaluated over the SimGrid simulator~\cite{SimGrid}, 
 in this paper real experiments were conducted over the grid'5000 platform. 
 
 \subsection{Grid'5000 architature and power consumption}
@@ -583,14 +583,14 @@ Two types of local networks are used, Ethernet or Infiniband networks which have
 Since grid'5000 is dedicated for testing, contrary to production grids it allows a user to deploy its own customized operating system on all the booked nodes. The user could have root rights and thus apply DVFS operations while executing a distributed application. Moreover, the grid'5000 testbed provides at some sites a power measurement tool to capture 
 the power consumption  for each node in those sites. The measured power is the overall consumed power by by all the components of a node at a given instant, such as CPU, hard drive, main-board, memory, ...  For more details refer to
 \cite{Energy_measurement}. To just measure the CPU power of one core in a node $j$, 
- firstly,  the power consumed by the node while being idle at instant $y$, noted as $\Pidle[jy]$, was measured. Then, the power was measured while running a single thread benchmark with no communication (no idle time) over the same node with its CPU scaled to the maximum available frequency. The latter power measured at time $x$ with maximum frequency for one core of node $j$ is noted $Pmax[jx]$. The difference between the two measured power consumption represents the 
+ firstly,  the power consumed by the node while being idle at instant $y$, noted as $\Pidle[jy]$, was measured. Then, the power was measured while running a single thread benchmark with no communication (no idle time) over the same node with its CPU scaled to the maximum available frequency. The latter power measured at time $x$ with maximum frequency for one core of node $j$ is noted $\Pmax[jx]$. The difference between the two measured power consumption represents the 
 dynamic power consumption of that core with the maximum frequency, see  figure(\ref{fig:power_cons}). 
 
 
 The dynamic power $\Pd[j]$ is computed as in equation (\ref{eq:pdyn})
 \begin{equation}
   \label{eq:pdyn}
-    \Pd[j] = \max_{x=\beta_1,\dots \beta_2} (Pmax[jx])  -  \min_{y=\Theta_1,\dots \Theta_2} (\Pidle[jy])
+    \Pd[j] = \max_{x=\beta_1,\dots \beta_2} (\Pmax[jx])  -  \min_{y=\Theta_1,\dots \Theta_2} (\Pidle[jy])
 \end{equation}
 
 where $\Pd[j]$ is the dynamic power consumption for one core of node $j$, 
@@ -599,7 +599,7 @@ $\lbrace\Theta_1,\Theta_2\rbrace$ is the time interval for the measured  idle po
 Therefore, the dynamic power of one core is computed as the difference between the maximum 
 measured value in maximum powers vector and the minimum measured value in the idle powers vector.
 
-On the other hand, the static power consumption by one core is a part of the measured idle power consumption of the node. Since in grid'5000 there is no way to measure precisely the consumed static power and in~\cite{Our_first_paper,pdsec2015,Rauber_Analytical.Modeling.for.Energy} it was assumed that  the static power  represents a ratio of the dynamic power, the value of the static power is assumed as  np[\%]{20} of dynamic power consumption of the core.
+On the other hand, the static power consumption by one core is a part of the measured idle power consumption of the node. Since in grid'5000 there is no way to measure precisely the consumed static power and in~\cite{Our_first_paper,pdsec2015,Rauber_Analytical.Modeling.for.Energy} it was assumed that  the static power  represents a ratio of the dynamic power, the value of the static power is assumed as  20\% of dynamic power consumption of the core.
 
 In the experiments presented in the following sections, two sites of grid'5000 were used, Lyon and Nancy sites. These two sites have in total seven different clusters as in figure (\ref{fig:grid5000}).
 
@@ -701,7 +701,7 @@ Table \ref{tab:sc} shows the number of nodes used from each cluster for each sce
 \centering
 \begin{tabular}{|*{4}{c|}}
 \hline
-\multirow{2}{*}{Scenario name}        & \multicolumn{2}{c|} {The participating clusters} \\ \cline{2-4} 
+\multirow{2}{*}{Scenario name}        & \multicolumn{3}{c|} {The participating clusters} \\ \cline{2-4} 
                                       & Cluster & Site           & No. of  nodes     \\ 
 \hline
 \multirow{3}{*}{Two sites / 16 nodes} & Taurus & Lyon                & 5                      \\ \cline{2-4} 
@@ -815,32 +815,32 @@ The best energy saving percentage was obtained in the one site scenario with 16
 
 
 Figure \ref{fig:per_d} presents the performance degradation percentages for all benchmarks.
-The performance degradation percentage  for the benchmarks running  on one site  with
+The performance degradation percentage  for the benchmarks running  on two sites  with
+16 or 32  nodes is on average equal to 8\% or 4\% respectively. 
+
+ \textcolor{red}{ 
+The proposed scaling algorithm selecting smaller frequencies in two sites scenario,
+due to decreasing in the computations to communications ratio when the number of nodes is increased and
+leads to less performance degradation percentage.  
+In contrast, the performance degradation percentage  for the benchmarks running  on one site  with
 16 or 32  nodes is on average equal to 3\% or 10\% respectively. 
-
- \textcolor{red}{please correct the following paragraph because I do not understand it at all! Stop using we, this because, effected, while, ...}
-   This because selecting smaller frequencies in the one site scenarios,
-when the computations grater than the communications , increase the number of the critical nodes 
-when the number of nodes increased. The inverse happens in the tow sites scenario,
-this due to the lower computations to communications ratio that decreased with highest 
-communications. Therefore, the number of the critical nodes are decreased. The average performance 
-degradation for the two sites scenario with 16 nodes is equal to 8\% and for 32 nodes is equal to 4\%.
+The inverse is happens in this scenario when the number of computing nodes is increased 
+the performance degradation percentage is decreased. So, using double number of computing 
+nodes when the communications occur in high speed network not decreased the computations to 
+communication ratio. Moreover, as shown in the figure \ref{fig:time_sen}, the execution time of one site scenario with 32 nodes 
+are less by approximately double, linear speed-up, for most of the benchmarks comparing to the one site with 16 nodes scenario. 
+This leads to increased the number of the critical nodes which any one of them may increased the overall the execution time of the benchmarks.
 The EP benchmarks is gives the bigger performance degradation ratio, because there is no 
-communications and no slack times in this benchmarks that is always their performance effected 
-by selecting big or small frequencies.
-The tradeoff between these scenarios can be computed as in the trade-off function \ref{eq:max}.
+communications and no slack times in this benchmarks which their performance govern 
+The tradeoff between these scenarios can be computed as in the tradeoff function \ref{eq:max}.
 Figure \ref{fig:dist}, presents the tradeoff distance for all benchmarks  over all 
 platform scenarios.  The one site scenario with 16 and 32 nodes had the best tradeoff distance 
-compared to the two sites scenarios, because the increase in the communications as mentioned before.
+compared to the two sites scenarios, due to the increase or decreased in the communications as mentioned before.
 The one site scenario with 16 nodes is the best scenario in term of energy and performance tradeoff,
-which on average is up 26\%.  Then, the tradeoff distance is related linearly to the  energy saving  
-percentage. Finally, the best energy and performance tradeoff depends on the increase in all of:
-1) the computations to communications ratio, 2) the differences in computing powers 
-between the computing nodes and 3) the differences in static and the dynamic powers of the nodes.
-
+which on average is up 26\%.  Therefore, the tradeoff distance is related linearly to the  energy saving  
+percentage. Finally, the best energy and performance tradeoff depends on the all of the following:
+1) the computations to communications ratio when there is a communications and slack times, 2) the differences in computing powers 
+between the computing nodes and 3) the differences in static and the dynamic powers of the nodes.}
 \subsection{The experimental results of multicores clusters}
 \label{sec.res-mc}
 The grid'5000 clusters have different number of cores embedded in their nodes
@@ -861,29 +861,29 @@ benchmarks, class D, over these four different scenarios are represented
 in the figures \ref{fig:eng-cons-mc} and \ref{fig:time-mc} respectively.
 The execution times of NAS  benchmarks over the one site multicores scenario 
 is higher than the execution time of those running over one site multicores scenario. 
-This because in the one site multicores scenario the communication is increased significantly,
+The reason in the one site multicores scenario the communication is increased significantly,
 and all node's cores  share  the same node network link which increased 
-the communication times. While, the execution times of the NAS benchmarks  over 
+the communication times. Whereas, the execution times of the NAS benchmarks  over 
 the two site  multicores scenario is less than those executed over the two 
-sites one core scenario. This because using multicores decrease the communications, 
-while the cores shared same nodes' link but the communications between the cores 
-are less than the communication times between the nodes over the long distance 
+sites one core scenario. This goes back when using multicores is decreasing the communications. 
+As explained previously, the cores shared same nodes' linkbut  the communications between the cores 
+are still less than the communication times between the nodes over the long distance 
 networks, and thus the over all execution time decreased. Generally, executing 
-the NAS benchmarks over the one site one core gives smaller execution times 
-comparing to other scenarios. This because each node in this scenario has it's 
+the NAS benchmarks over the one site one core scenario gives smaller execution times 
+comparing to other scenarios. This due to each node in this scenario has it's 
 dedicated network link that used independently by one core, while in the other 
-scenarios the communication times are higher when using long distance communication 
+scenarios the communication times are higher when using long distance communications 
 link or using the  shared link communications between cores of each node. 
 On the other hand, the energy consumptions of the NAS benchmarks over the 
 one site one cores is less than the one site multicores scenario because 
 this scenario had less execution time as mentioned before. Also, in the 
 one site one core scenario the computations to communications ratio is 
 higher, then the new scaled frequencies are decreased the dynamic energy 
-consumption, because the dynamic power consumption are decreased exponentially 
+consumption which is decreased exponentially 
 with the new frequency scaling factors. These experiments also showed, the energy 
 consumption and the execution times of EP and MG benchmarks over these four 
 scenarios are not change a lot, because there are no or small communications 
- which are increase or decrease the static power consumptions. 
+which are increase or decrease the static power consumptions. 
 The other benchmarks were showed that their energy consumptions and execution times 
 are changed according to the decreasing or increasing in the communication 
 times that are different from scenario to other or due to the amount of 
@@ -892,44 +892,42 @@ communications in each of them.
 The energy saving percentages of all NAS benchmarks, as in figure 
 \ref{fig:eng-s-mc}, running over these four scenarios are presented. The figure 
 showed the energy saving percentages of NAS benchmarks over two sites multicores scenario is higher 
-than two sites once core scenario, this because the the computation 
-times in the two sites multicores scenario is higher than the computation times 
-of the two sites one core scenario, then the more reduction in the 
+than two sites once core scenario, because  the computation 
+times in this scenario is higher than the other one, then the more reduction in the 
 dynamic energy can be obtained as mentioned previously. In contrast, in the one site one 
 core and one site multicores scenarios the energy saving percentages 
-are approximately equivalent, on average they are up to 25\%. This 
-because in the both scenarios there are a small difference  in the 
+are approximately equivalent, on average they are up to 25\%. In these  both scenarios there are a small difference  in the 
 computations to communications ratio, leading the proposed scaling algorithm 
 to selects the frequencies proportionally to these ratios and keeping 
 as much as possible the energy saving percentages the same. The 
 performance degradation percentages of NAS benchmarks are presented in
 figure \ref{fig:per-d-mc}. This figure indicates that performance 
 degradation percentages of running NAS benchmarks over two sites 
-multocores, on average is equal to 7\%,  gives more performance degradation percentage
+multocores scenario, on average is equal to 7\%,  gives more performance degradation percentage
 than two sites  one core scenario, which on average is equal to 4\%. 
-This because when using the two sites multicores scenario increased 
-the computations to communications ratio, which may be increased the effect
-on the overall execution time  when the proposed scaling algorithm is applied and scaling down the frequencies.  
+Moreover, using the two sites multicores scenario increased 
+the computations to communications ratio, which may be increased 
+the overall execution time  when the proposed scaling algorithm is applied and scaling down the frequencies.  
 The inverse was happened when the benchmarks are executed  over one 
 site one core scenario their performance degradation percentages, on average
 is equal to 10\%, are higher than those executed over one sit one core, 
-which on average is equal to 7\%. This because  in one site 
+which on average is equal to 7\%. So, in one site 
 multicores scenario the computations to communications ratio is decreased
-as mentioned before, thus selecting new frequencies are less effect 
-on the overall execution time. The tradeoff distances of all NAS 
+as mentioned before, thus selecting new frequencies are not increased 
+the overall execution time. The tradeoff distances of all NAS 
 benchmarks over all scenarios are presented in the figure \ref{fig:dist-mc}.
 These  tradeoff distances are used to verified which scenario is the best in term of 
 energy and performance ratio. The one sites multicores scenario is the best  scenario in term of
 energy and performance tradeoff, on average is equal to 17.6\%, when comparing to the one site one core 
-scenario, one average is equal to 15.3\%.  This because the one site multicores  scenario 
+scenario, one average is equal to 15.3\%.  The one site multicores  scenario 
 has the same  energy saving percentages of the one site one core scenario but
 with less performance degradation. The two sites multicores scenario is gives better 
 energy and performance tradeoff, one average is equal to 14.7\%, than the two sites
 one core, on average is equal to 13.3\%.
 Finally, using multicore in both scenarios increased the energy and performance tradeoff 
-distance. This is because using multicores are increased the computations to communications 
-ratio in two sites scenario and thus the energy saving increased over the performance degradation, whereas  decreased this ratio 
-in one site scenario causing the performance degradation decreased over the energy saving.
+distance. This generally due to using multicores was increased the computations to communications 
+ratio in two sites scenario and thus the energy saving percentage increased over the performance degradation percentage, whereas  this ratio was decreased  
+in one site  scenario causing the performance degradation percentage decreased over the energy saving percentage.