\newcommand{\Told}{\Xsub{T}{Old}}
\begin{document}
-\title{Energy Consumption Reduction in heterogeneous architecture using DVFS}
+\title{Energy Consumption Reduction In a Heterogeneous Architecture Using DVFS}
\author{%
\IEEEauthorblockN{%
Raphaël Couturier,
Ahmed Fanfakh and
Arnaud Giersch
- }
+ }
\IEEEauthorblockA{%
FEMTO-ST Institute\\
University of Franche-Comté\\
\section{Related works}
\label{sec.relwork}
-
-
-
+Energy reduction process for a high performance clusters recently performed using dynamic voltage and frequency scaling (DVFS) technique. DVFS is a technique enabled in a modern processors to scaled down both of the voltage and the frequency of the CPU while it is in the computing mode to reduce the energy consumption. DVFS is also allowed in the graphical processors GPUs, to achieved the same goal. Applying DVFS has a dramatical side effect if it is applied to minimum levels to gain more energy reduction, producing a high percentage of performance degradations for the parallel applications. Many researchers used different strategies to solve this nonlinear problem for example in~\cite{19,42}, their methods add big overheads to the algorithm to select the
+suitable frequency. In this paper we present a method to find the optimal
+set of frequency scaling factors for a heterogeneous cluster to simultaneously optimize both the energy and the execution time without adding a big overhead.
+This work is developed from our previous work of a homogeneous cluster~\cite{45}. Therefore we are interested to present some works that concerned the heterogeneous clusters enabled DVFS. In general, the heterogeneous cluster works fall into two categorizes: GPUs-CPUs heterogeneous clusters and CPUs-CPUs heterogeneous clusters. In GPUs-CPUs heterogeneous clusters some parallel tasks executed on a GPUs and the others executed on a CPUs. As an example of this works, Luley et al.~\cite{51}, proposed a heterogeneous cluster composed of Intel Xeon CPUs and NVIDIA GPUs. Their main goal is to determined the energy efficiency as a function of performance per watt, the best tradeoff is done when the performance per watt function is maximized. In the work of Kia Ma et al.~\cite{49}, They developed a scheduling algorithm to distribute different workloads proportional to the computing power of the node to be executed on a CPU or a GPU, emphasize all tasks must be finished in the same time.
+Recently, Rong et al.~\cite{50}, Their study explain that a heterogeneous clusters enabled DVFS using GPUs and CPUs gave better energy and performance efficiency
+than other clusters composed of only CPUs. The CPUs-CPUs heterogeneous clusters consist of number of computing nodes all of the type CPU. Our work in this paper can be classified to this type of the clusters. As an example of this works see Naveen et al.~\cite{52} work, They developed a policy to dynamically assigned the frequency to a heterogeneous cluster. The goal is to minimizing a fixed metric of $energy*delay^2$. Where our proposed method is automatically optimized the relation between the energy and the delay of the iterative applications. Other works such as Lizhe et al.~\cite{53}, their algorithm divided the executed tasks into two types: the critical and non critical tasks. The algorithm scaled down the frequency of the non critical tasks as function to the amount of the slack and communication times that have with maximum of performance degradation percentage of 10\%. In our method there is no fixed bounds for performance degradation percentage and the bound is dynamically computed according to the energy and the performance tradeoff relation of the executed application.
+There are some approaches used a heterogeneous cluster composed from two different types of Intel and AMD processors such as~\cite{54} and \cite{55}, they predicated both the energy and the performance for each frequency gear, then the algorithm selected the best gear that gave the best tradeoff. In contrast our algorithm works over a heterogeneous platform composed of four different types of processors. Others approaches such as \cite{56} and \cite{57}, they are selected the best frequencies for a specified heterogeneous clusters offline using some heuristic methods. While our proposed algorithm works online during the execution time of iterative application. Greedy dynamic approach used by Chen et al.~\cite{58}, minimized the power consumption of a heterogeneous severs with time/space complexity, this approach had considerable overhead. In our proposed scaling algorithm has very small overhead and it is works without any previous analysis for the application time complexity.
\section{The performance and energy consumption measurements on heterogeneous architecture}
\label{sec.exe}
have the same network bandwidth and latency.
-\begin{figure}[t]
+
+ The overall execution time of a distributed iterative synchronous application over a heterogeneous platform consists of the sum of the computation time and the communication time for every iteration on a node. However, due to the heterogeneous computation power of the computing nodes, slack times might occur when fast nodes have to
+ wait, during synchronous communications, for the slower nodes to finish their computations (see Figure~(\ref{fig:heter}).
+ Therefore, the overall execution time of the program is the execution time of the slowest
+ task which have the highest computation time and no slack time.
+
+ \begin{figure}[t]
\centering
\includegraphics[scale=0.6]{fig/commtasks}
\caption{Parallel tasks on a heterogeneous platform}
\label{fig:heter}
\end{figure}
- The overall execution time of a distributed iterative synchronous application over a heterogeneous platform consists of the sum of the computation time and the communication time for every iteration on a node. However, due to the heterogeneous computation power of the computing nodes, slack times might occur when fast nodes have to
- wait, during synchronous communications, for the slower nodes to finish their computations (see Figure~(\ref{fig:heter})).
- Therefore, the overall execution time of the program is the execution time of the slowest
- task which have the highest computation time and no slack time.
-
Dynamic Voltage and Frequency Scaling (DVFS) is a process, implemented in modern processors, that reduces the energy consumption
of a CPU by scaling down its voltage and frequency. Since DVFS lowers the frequency of a CPU and consequently its computing power, the execution time of a program running over that scaled down processor might increase, especially if the program is compute bound. The frequency reduction process can be expressed by the scaling factor S which is the ratio between the maximum and the new frequency of a CPU as in EQ (\ref{eq:s}).
\begin{equation}
\subsection{Energy model for heterogeneous platform}
-
Many researchers~\cite{9,3,15,26} divide the power consumed by a processor into
two power metrics: the static and the dynamic power. While the first one is
consumed as long as the computing unit is turned on, the latter is only consumed during
time simultaneously. But the main objective is to produce maximum energy
reduction with minimum execution time reduction.
-Many researchers used different strategies to solve this nonlinear problem for example
-in~\cite{19,42}, their methods add big overheads to the algorithm to select the
-suitable frequency. In this paper we present a method to find the optimal
-set of frequency scaling factors to simultaneously optimize both energy and execution time
- without adding a big overhead. \textbf{put the last two phrases in the related work section}
Our solution for this problem is to make the optimization process for energy and execution time follow the same
F_{i} = \frac{Fmax_i}{Scp_i},~{i=1,2,\cdots,N}
\end{equation}
If the computed initial frequency for a node is not available in the gears of that node, the computed initial frequency is replaced by the nearest available frequency.
-In figure (\ref{fig:st_freq}), the nodes are sorted by their computing powers in ascending order and the frequencies of the faster nodes are scaled down according to the computed initial frequency scaling factors. The resulting new frequencies are coloured in blue in figure (\ref{fig:st_freq}). This set of frequencies can be considered as a higher bound for the search space of the optimal vector of frequencies because selecting frequency scaling factors higher than the higher bound will not improve the performance of the application and it will increase its overall energy consumption. Therefore the frequency selecting factors algorithm starts its search method from these initial frequencies and takes a downward search direction. If the algorithm starts to search from the first frequencies of all nodes, regardless the higher bound frequencies, at each step the predicted performance and energy are degreased together, then the best distance be unreachable. This case is similar to homogeneous scaling algorithm when all nodes in the cluster has the same computing power, therefore there is a smaller distance between the performance and the energy curves, while in a heterogeneous cluster the distance is bigger and the energy saving against smaller execution time is higher, as an example see figure~(\ref{fig:r1} and \ref{fig:r2}). The algorithm iterates on all left frequencies, from the higher bound until all nodes reach their minimum frequencies, to compute their overall energy consumption and performance, and select the optimal frequency scaling factors vector. At each iteration the algorithm determines the slowest node according to EQ(\ref{eq:perf}) and keeps its frequency unchanged, while it lowers the frequency of all other nodes by one gear. The new overall energy consumption and execution time are computed according to the new scaling factors. The optimal set of frequency scaling factors is the set that gives the highest distance according to the objective function EQ(\ref{eq:max}).
+In figure (\ref{fig:st_freq}), the nodes are sorted by their computing powers in ascending order and the frequencies of the faster nodes are scaled down according to the computed initial frequency scaling factors. The resulting new frequencies are colored in blue in figure (\ref{fig:st_freq}). This set of frequencies can be considered as a higher bound for the search space of the optimal vector of frequencies because selecting frequency scaling factors higher than the higher bound will not improve the performance of the application and it will increase its overall energy consumption. Therefore the algorithm that selects the frequency scaling factors starts the search method from these initial frequencies and takes a downward search direction toward lower frequencies. The algorithm iterates on all left frequencies, from the higher bound until all nodes reach their minimum frequencies, to compute their overall energy consumption and performance, and select the optimal frequency scaling factors vector. At each iteration the algorithm determines the slowest node according to EQ(\ref{eq:perf}) and keeps its frequency unchanged, while it lowers the frequency of all other nodes by one gear.
+The new overall energy consumption and execution time are computed according to the new scaling factors. The optimal set of frequency scaling factors is the set that gives the highest distance according to the objective function EQ(\ref{eq:max}).
+
+The plots~(\ref{fig:r1} and \ref{fig:r2}) illustrate the normalized performance and consumed energy for an application running on a homogeneous platform and a heterogeneous platform respectively while increasing the scaling factors. It can be noticed that in a homogeneous platform the search for the optimal scaling factor should be started from the maximum frequency because the performance and the consumed energy is decreased since the beginning of the plot. On the other hand, in the heterogeneous platform the performance is maintained at the beginning of the plot even if the frequencies of the faster nodes are decreased until the scaled down nodes have computing powers lower than the slowest node. In other words, until they reach the higher bound. It can also be noticed that the higher the difference between the faster nodes and the slower nodes is, the bigger the maximum distance between the energy curve and the performance curve is while varying the scaling factors which results in bigger energy savings.
\begin{figure}[t]
\centering
\includegraphics[scale=0.5]{fig/start_freq}
\section{Experimental results}
\label{sec.expe}
-To evaluate the efficiency and the overall energy consumption reduction of algorithm~\ref{HSA}), it was applied to the NAS parallel benchmarks NPB v3.3
+To evaluate the efficiency and the overall energy consumption reduction of algorithm~(\ref{HSA}), it was applied to the NAS parallel benchmarks NPB v3.3
\cite{44}. The experiments were executed on the simulator SimGrid/SMPI
v3.10~\cite{casanova+giersch+legrand+al.2014.versatile} which offers easy tools to create a heterogeneous platform and run message passing applications over it. The heterogeneous platform that was used in the experiments, had one core per node because just one process was executed per node. The heterogeneous platform was composed of four types of nodes. Each type of nodes had different characteristics such as the maximum CPU frequency, the number of
available frequencies and the computational power, see table
(\ref{table:platform}). The characteristics of these different types of nodes are inspired from the specifications of real Intel processors. The heterogeneous platform had up to 144 nodes and had nodes from the four types in equal proportions, for example if a benchmark was executed on 8 nodes, 2 nodes from each type were used. Since the constructors of CPUs do not specify the dynamic and the static power of their CPUs, for each type of node they were chosen proportionally to its computing power (FLOPS). In the initial heterogeneous platform, while computing with highest frequency, each node consumed power proportional to its computing power which 80\% of it was dynamic power and the rest was 20\% was static power, the same assumption was made in \cite{45,3}. Finally, These nodes were connected via an ethernet network with 1 Gbit/s bandwidth.
-\textbf{modify the characteristics table by replacing the similar column with the computing power of the different types of nodes in flops}
-
-
- The proposed scaling algorithm has a small
-execution time: for a heterogeneous cluster composed of four different types of
-nodes having the characteristics presented in table~(\ref{table:platform}), it
-takes on average \np[ms]{0.04} for 4 nodes and \np[ms]{0.15} on average for 144
-nodes to compute the best scaling factors vector. The algorithm complexity is $O(F\cdot (N \cdot4) )$, where $F$ is the
-number of iterations and $N$ is the number of computing nodes. The algorithm
-needs from 12 to 20 iterations to select the best vector of frequency scaling factors that gives the results of the next section.
-
\begin{table}[htb]
\caption{Heterogeneous nodes characteristics}
% title of Table
\centering
\begin{tabular}{|*{7}{l|}}
\hline
- Node & Similar & Max & Min & Diff. & Dynamic & Static \\
- type & to & Freq. GHz & Freq. GHz & Freq. GHz & power & power \\
+ Node &Simulated & Max & Min & Diff. & Dynamic & Static \\
+ type &GFLOPS & Freq. & Freq. & Freq. & power & power \\
+ & & GHz & GHz &GHz & & \\
\hline
- 1 & core-i3 & 2.5 & 1.2 & 0.1 & 20~w &4~w \\
- & 2100T & & & & & \\
+ 1 &40 & 2.5 & 1.2 & 0.1 & 20~w &4~w \\
+ & & & & & & \\
\hline
- 2 & Xeon & 2.66 & 1.6 & 0.133 & 25~w &5~w \\
- & 7542 & & & & & \\
+ 2 &50 & 2.66 & 1.6 & 0.133 & 25~w &5~w \\
+ & & & & & & \\
\hline
- 3 & core-i5 & 2.9 & 1.2 & 0.1 & 30~w &6~w \\
- & 3470s & & & & & \\
+ 3 &60 & 2.9 & 1.2 & 0.1 & 30~w &6~w \\
+ & & & & & & \\
\hline
- 4 & core-i7 & 3.4 & 1.6 & 0.133 & 35~w &7~w \\
- & 2600s & & & & & \\
+ 4 &70 & 3.4 & 1.6 & 0.133 & 35~w &7~w \\
+ & & & & & & \\
\hline
\end{tabular}
\label{table:platform}
\subsection{The experimental results of the scaling algorithm}
\label{sec.res}
-<<<<<<< HEAD
-The proposed algorithm was applied to the seven parallel NAS benchmarks (EP, CG, MG, FT, BT, LU and SP) and the benchmarks were executed with the three classes: A,B and C. However, due to the lack of space in this paper, only the results of the biggest class, C, are presented while being run on different number of nodes, ranging from 4 to 128 or 144 nodes depending on the benchmark being executed.
+
+The proposed algorithm was applied to the seven parallel NAS benchmarks (EP, CG, MG, FT, BT, LU and SP) and the benchmarks were executed with the three classes: A,B and C. However, due to the lack of space in this paper, only the results of the biggest class, C, are presented while being run on different number of nodes, ranging from 4 to 128 or 144 nodes depending on the benchmark being executed. Indeed, the benchmarks CG, MG, LU, EP and FT should be executed on $1, 2, 4, 8, 16, 32, 64, 128$ nodes. The other benchmarks such as BT and SP should be executed on $1, 4, 9, 16, 36, 64, 144$ nodes.
\end{tabular}
\label{table:res_128n}
\end{table}
-The overall energy consumption was computed for each instance according to the energy consumption model EQ(\ref{eq:energy}), with and without applying the algorithm. The execution time was also measured for all these experiments. Then, the energy saving and performance degradation percentages were computed for each instance. The results are presented in tables (\ref{table:res_4n}, \ref{table:res_8n}, \ref{table:res_16n}, \ref{table:res_32n}, \ref{table:res_64n} and \ref{table:res_128n}).
-These tables show the experimental results for running the NAS parallel benchmarks on different number of nodes. The experiments show that the algorithm reduce significantly the energy consumption (up to 35\%) and tries to limit the performance degradation. They also show that the energy saving percentage is decreased when the number of the computing nodes is increased. This reduction is due to the increase of the communication times compared to the execution times when the benchmarks are run over a high number of nodes. Indeed, the benchmarks with the same class, C, are executed on different number of nodes, so the computation required for each iteration is divided by the number of computing nodes. On the other hand, more communications are required when increasing the number of nodes so the static energy is increased linearly according to the communication time and the dynamic power is less relevant in the overall energy consumption. Therefore, reducing the frequency with algorithm~\ref{HSA}) have less effect in reducing the overall energy savings. It can also be noticed that for the benchmarks EP and SP that contain little or no communications, the energy savings are not significantly affected with the high number of nodes. No experiments were conducted using bigger classes such as D, because they require a lot of memory(more than 64GB) when being executed by the simulator on one machine.
+The overall energy consumption was computed for each instance according to the energy consumption model EQ(\ref{eq:energy}), with and without applying the algorithm. The execution time was also measured for all these experiments. Then, the energy saving and performance degradation percentages were computed for each instance.
+The results are presented in tables (\ref{table:res_4n}, \ref{table:res_8n}, \ref{table:res_16n}, \ref{table:res_32n}, \ref{table:res_64n} and \ref{table:res_128n}). All these results are the average values from many experiments for energy savings and performance degradation.
+
+The tables show the experimental results for running the NAS parallel benchmarks on different number of nodes. The experiments show that the algorithm reduce significantly the energy consumption (up to 35\%) and tries to limit the performance degradation. They also show that the energy saving percentage is decreased when the number of the computing nodes is increased. This reduction is due to the increase of the communication times compared to the execution times when the benchmarks are run over a high number of nodes. Indeed, the benchmarks with the same class, C, are executed on different number of nodes, so the computation required for each iteration is divided by the number of computing nodes. On the other hand, more communications are required when increasing the number of nodes so the static energy is increased linearly according to the communication time and the dynamic power is less relevant in the overall energy consumption. Therefore, reducing the frequency with algorithm~(\ref{HSA}) have less effect in reducing the overall energy savings. It can also be noticed that for the benchmarks EP and SP that contain little or no communications, the energy savings are not significantly affected with the high number of nodes. No experiments were conducted using bigger classes such as D, because they require a lot of memory(more than 64GB) when being executed by the simulator on one machine.
The maximum distance between the normalized energy curve and the normalized performance for each instance is also shown in the result tables. It is decreased in the same way as the energy saving percentage. The tables also show that the performance degradation percentage is not significantly increased when the number of computing nodes is increased because the computation times are small when compared to the communication times.
\begin{figure}
\centering
- \subfloat[CG, MG, LU and FT benchmarks]{%
- \includegraphics[width=.23185\textwidth]{fig/avg_eq}\label{fig:avg_eq}}%
+ \subfloat[Energy saving]{%
+ \includegraphics[width=.2315\textwidth]{fig/energy}\label{fig:energy}}%
\quad%
- \subfloat[BT and SP benchmarks]{%
- \includegraphics[width=.23185\textwidth]{fig/avg_neq}\label{fig:avg_neq}}
+ \subfloat[Performance degradation ]{%
+ \includegraphics[width=.2315\textwidth]{fig/per_deg}\label{fig:per_deg}}
\label{fig:avg}
- \caption{The average of energy and performance for all NAS benchmarks running with difference number of nodes}
+ \caption{The energy and performance for all NAS benchmarks running with difference number of nodes}
\end{figure}
-In the NAS benchmarks there are some programs executed on different number of
-nodes. The benchmarks CG, MG, LU and FT executed on 2 to a power of (1, 2, 4, 8,
-\dots{}) of nodes. The other benchmarks such as BT and SP executed on 2 to a
-power of (1, 2, 4, 9, \dots{}) of nodes. We are take the average of energy
-saving, performance degradation and distances for all results of NAS
-benchmarks. The average of values of these three objectives are plotted to the number of
-nodes as in plots (\ref{fig:avg_eq} and \ref{fig:avg_neq}). In CG, MG, LU, and
-FT benchmarks the average of energy saving is decreased when the number of nodes
-is increased because the communication times is increased as mentioned
-before. Thus, the average of distances (our objective function) is decreased
-linearly with energy saving while keeping the average of performance degradation approximately is
-the same. In BT and SP benchmarks, the average of the energy saving is not decreased
-significantly compare to other benchmarks when the number of nodes is
-increased. Nevertheless, the average of performance degradation approximately
-still the same ratio. This difference is depends on the characteristics of the
-benchmark such as the computations to communications ratio that has.
+
+ Plots (\ref{fig:energy} and \ref{fig:per_deg}) present the energy saving and performance degradation respectively for all the benchmarks according to the number of used
+nodes. As shown in the first plot, the energy saving percentages of the benchmarks MG, LU, BT and FT are decreased linearly when the the number of nodes is increased. While for the EP and SP benchmarks, the energy saving percentage is not affected by the increase of the number of computing nodes, because in these benchmarks there are no communications. Finally, the energy saving of the GC benchmark is significantly decreased when the number of nodes is increased because this benchmark has more communications than the others. The second plot shows that the performance degradation percentages of most of the benchmarks are decreased when they run on a big number of nodes because they spend more time communicating than computing, thus, scaling down the frequencies of some nodes have less effect on the performance.
+
+
+
\subsection{The results for different power consumption scenarios}
-The results of the previous section are obtained using a percentage of 80\% for
-dynamic power and 20\% for static power of the total power consumption of a CPU. In this
-section we are change these ratio by using two others power scenarios. Because is
-interested to measure the ability of the proposed algorithm when these power ratios are changed.
-In fact, we are used two different scenarios for dynamic and static power ratios in addition to the previous
-scenario in section (\ref{sec.res}). Therefore, we have three different
-scenarios for three different dynamic and static power ratios refer to these as:
-70\%-20\%, 80\%-20\% and 90\%-10\% scenario respectively. The results of these scenarios
-running the NAS benchmarks class C on 8 or 9 nodes are place in the tables
-(\ref{table:res_s1} and \ref{table:res_s2}).
+The results of the previous section were obtained while using processors that consume during computation an overall power which is 80\% composed of dynamic power and 20\% of static power. In this
+section, these ratios are changed and two new power scenarios are considered in order to evaluate how the proposed algorithm adapts itself according to the static and dynamic power values. The two new power scenarios are the following:
+\begin{itemize}
+\item 70\% dynamic power and 30\% static power
+\item 90\% dynamic power and 10\% static power
+\end{itemize}
+The NAS parallel benchmarks were executed again over processors that follow the the new power scenarios. The class C of each benchmark was run over 8 or 9 nodes and the results are presented in tables (\ref{table:res_s1} and \ref{table:res_s2}). These tables show that the energy saving percentage of the 70\%-30\% scenario is less for all benchmarks compared to the energy saving of the 90\%-10\% scenario. Indeed, in the latter more dynamic power is consumed when nodes are running on their maximum frequencies, thus, scaling down the frequency of the nodes results in higher energy savings than in the 70\%-30\% scenario. On the other hand, the performance degradation percentage is less in the 70\%-30\% scenario compared to the 90\%-10\% scenario. This is due to the higher static power percentage in the first scenario which makes it more relevant in the overall consumed energy. Indeed, the static energy is related to the execution time and if the performance is degraded the total consumed static energy is directly increased. Therefore, the proposed algorithm do not scales down much the frequencies of the nodes in order to limit the increase of the execution time and thus limiting the effect of the consumed static energy .
+
+The two new power scenarios are compared to the old one in figure (\ref{fig:sen_comp}). It shows the average of the performance degradation, the energy saving and the distances for all NAS benchmarks of class C running on 8 or 9 nodes. The comparison shows that the energy saving ratio is proportional to the dynamic power ratio: it is increased when applying the 90\%-10\% scenario because at maximum frequency the dynamic energy is the the most relevant in the overall consumed energy and can be reduced by lowering the frequency of some processors. On the other hand, the energy saving is decreased when the 70\%-30\% scenario is used because the dynamic energy is less relevant in the overall consumed energy and lowering the frequency do not returns big energy savings.
+Moreover, the average of the performance degradation is decreased when using a higher ratio for static power (e.g. 70\%-30\% scenario and 80\%-20\% scenario). Since the proposed algorithm optimizes the energy consumption when using a higher ratio for dynamic power the algorithm selects bigger frequency scaling factors that result in more energy saving but less performance, for example see the figure (\ref{fig:scales_comp}). The opposite happens when using a higher ratio for static power, the algorithm proportionally selects smaller scaling values which results in less energy saving but less performance degradation.
+
\begin{table}[htb]
\caption{The results of 70\%-30\% powers scenario}
\subfloat[Comparison the average of the results on 8 nodes]{%
\includegraphics[width=.22\textwidth]{fig/sen_comp}\label{fig:sen_comp}}%
\quad%
- \subfloat[Comparison the selected frequency scaling factors for 8 nodes]{%
+ \subfloat[Comparison the selected frequency scaling factors of MG benchmark class C running on 8 nodes]{%
\includegraphics[width=.24\textwidth]{fig/three_scenarios}\label{fig:scales_comp}}
\label{fig:comp}
\caption{The comparison of the three power scenarios}
\end{figure}
-To compare the results of these three powers scenarios, we are take the average of the performance degradation, the energy saving and the distances for all NAS benchmarks running on 8 or 9 nodes of class C, as in figure (\ref{fig:sen_comp}). Thus, according to the average of these results, the energy saving ratio is increased when using a higher percentage for dynamic power (e.g. 90\%-10\% scenario), due to increase in dynamic energy. While the average of energy saving is decreased in 70\%-30\% scenario. Because the static energy consumption is increase. Moreover, the average of distances is more related to energy saving changes. The average of the performance degradation is decreased when using a higher ratio for static power (e.g. 70\%-30\% scenario and 80\%-20\% scenario). The raison behind these relations, that the proposed algorithm optimize both energy consumption and performance in the same time. Therefore, when using a higher ratio for dynamic power the algorithm selecting bigger frequency scaling factors values, more energy saving versus more performance degradation, for example see the figure (\ref{fig:scales_comp}). The inverse happen when using a higher ratio for static power, the algorithm proportionally selects a smaller scaling values, less energy saving versus less performance degradation. This is because the
-algorithm is optimizes the static energy consumption that is always related to the execution time.
+
\subsection{The verifications of the proposed method}
\label{sec.verif}
-The precision of the proposed algorithm mainly depends on the execution time prediction model EQ(\ref{eq:perf}) and the energy model EQ(\ref{eq:energy}). The energy model is significantly depends on the execution time model, that the static energy is related linearly. So, our work is depends mainly on execution time model. To verifying this model, we are compared the predicted execution time with the real execution time (Simgrid time) values that gathered offline from the NAS benchmarks class B executed on 8 or 9 nodes. The execution time model can predicts the real execution time by maximum normalized error equal to 0.03 for all the NAS benchmarks. The second verification that we are made is for the proposed scaling algorithm to prove its ability to selects the best vector of the frequency scaling factors. Therefore, we are expand the algorithm to test at each iteration the frequency scaling factor of the slowest node with the all available scaling factors of the other nodes, all possible solutions. This version of the algorithm is applied to different NAS benchmarks classes with different number of nodes. The results from the expanded algorithms and the proposed algorithm are identical. While the proposed algorithm is runs by 10 times faster on average compare to the expanded algorithm.
+The precision of the proposed algorithm mainly depends on the execution time prediction model defined in EQ(\ref{eq:perf}) and the energy model computed by EQ(\ref{eq:energy}).
+The energy model is also significantly dependent on the execution time model because the static energy is linearly related the execution time and the dynamic energy is related to the computation time. So, all of the work presented in this paper is based on the execution time model. To verify this model, the predicted execution time was compared to the real execution time over Simgrid for all the NAS parallel benchmarks running class B on 8 or 9 nodes. The comparison showed that the proposed execution time model is very precise, the maximum normalized difference between the predicted execution time and the real execution time is equal to 0.03 for all the NAS benchmarks.
+
+Since the proposed algorithm is not an exact method and do not test all the possible solutions (vectors of scaling factors) in the search space and to prove its efficiency, it was compared on small instances to a brute force search algorithm that tests all the possible solutions. The brute force algorithm was applied to different NAS benchmarks classes with different number of nodes. The solutions returned by the brute force algorithm and the proposed algorithm were identical and the proposed algorithm was on average 10 times faster than the brute force algorithm. It has a small
+execution time: for a heterogeneous cluster composed of four different types of nodes having the characteristics presented in table~(\ref{table:platform}), it
+takes on average \np[ms]{0.04} for 4 nodes and \np[ms]{0.15} on average for 144 nodes to compute the best scaling factors vector. The algorithm complexity is $O(F\cdot (N \cdot4) )$, where $F$ is the number of iterations and $N$ is the number of computing nodes. The algorithm
+needs from 12 to 20 iterations to select the best vector of frequency scaling factors that gives the results of the section (\ref{sec.res}).
\section{Conclusion}
\label{sec.concl}