]> AND Private Git Repository - mpi-energy2.git/blobdiff - mpi-energy2-extension/Heter_paper.tex
Logo AND Algorithmique Numérique Distribuée

Private GIT Repository
adding new section
[mpi-energy2.git] / mpi-energy2-extension / Heter_paper.tex
index 7252e4409d6154dfecb92e59bf290e31917f695e..e30d62cdb03dbe5f6b62ecc1975f51d67eadee73 100644 (file)
@@ -54,7 +54,7 @@
 \newcommand{\Sopt}[1][]{\Xsub{S}{opt}_{#1}}
 \newcommand{\Tcm}[1][]{\Xsub{T}{cm}_{\fxheight{#1}}}
 \newcommand{\Tcp}[1][]{\Xsub{T}{cp}_{#1}}
-\newcommand{\Ppeak}[1][]{\Xsub{P}{peak}_{#1}}
+\newcommand{\Pmax}[1][]{\Xsub{P}{max}_{#1}}
 \newcommand{\Pidle}[1][]{\Xsub{P}{idle}_{\fxheight{#1}}}
 \newcommand{\TcpOld}[1][]{\Xsub{T}{cpOld}_{#1}}
 \newcommand{\Tnew}{\Xsub{T}{New}}
@@ -350,9 +350,9 @@ maximum frequency for all  nodes:
 \end{equation}
 
 Where $\Ereduced$  is computed using (\ref{eq:energy}) and $\Eoriginal$ is 
-computed as in ().
+computed as in (\ref{eq:eorginal}).
+
 
-\textcolor{red}{A reference is missing}
 \begin{equation}
   \label{eq:eorginal}
     \Eoriginal = \sum_{i=1}^{N} \sum_{j=1}^{M} ( \Pd[ij] \cdot  \Tcp[ij])  + 
@@ -477,9 +477,7 @@ in~\cite{Zhuo_Energy.efficient.Dynamic.Task.Scheduling,Rauber_Analytical.Modelin
   \label{dvfs}
 \end{algorithm}
 
-\subsection{The algorithm details}
 
-\textcolor{red}{Delete the subsection if there's only one.}
 
 In this section, the scaling factors selection algorithm for  grids, algorithm~\ref{HSA}, is presented. It selects the vector of the frequency
 scaling factors  that gives the best trade-off between minimizing the
@@ -578,29 +576,28 @@ Grid'5000~\cite{grid5000} is a large-scale testbed that consists of ten sites di
 which is the French National Telecommunication Network for Technology.
 Each site of the grid is composed of few heterogeneous 
 computing clusters and each cluster contains many homogeneous nodes. In total,
- grid'5000 has about  one thousand heterogeneous nodes and eight thousand cores.  In each site,
+grid'5000 has about  one thousand heterogeneous nodes and eight thousand cores.  In each site,
 the clusters and their nodes are connected via  high speed local area networks. 
 Two types of local networks are used, Ethernet or Infiniband networks which have  different characteristics in terms of bandwidth and latency.  
 
 Since grid'5000 is dedicated for testing, contrary to production grids it allows a user to deploy its own customized operating system on all the booked nodes. The user could have root rights and thus apply DVFS operations while executing a distributed application. Moreover, the grid'5000 testbed provides at some sites a power measurement tool to capture 
 the power consumption  for each node in those sites. The measured power is the overall consumed power by by all the components of a node at a given instant, such as CPU, hard drive, main-board, memory, ...  For more details refer to
 \cite{Energy_measurement}. To just measure the CPU power of one core in a node $j$, 
- firstly,  the power consumed by the node while being idle at instant $y$, noted as $\Pidle[jy]$, was measured. Then, the power was measured while running a single thread benchmark with no communication (no idle time) over the same node with its CPU scaled to the maximum available frequency. The latter power measured at time $x$ with maximum frequency for one core of node $j$ is noted $P\max[jx]$. The difference between the two measured power consumption represents the 
+ firstly,  the power consumed by the node while being idle at instant $y$, noted as $\Pidle[jy]$, was measured. Then, the power was measured while running a single thread benchmark with no communication (no idle time) over the same node with its CPU scaled to the maximum available frequency. The latter power measured at time $x$ with maximum frequency for one core of node $j$ is noted $Pmax[jx]$. The difference between the two measured power consumption represents the 
 dynamic power consumption of that core with the maximum frequency, see  figure(\ref{fig:power_cons}). 
 
-\textcolor{red}{why maximum and minimum, change peak in the equation and the figure}
 
 The dynamic power $\Pd[j]$ is computed as in equation (\ref{eq:pdyn})
 \begin{equation}
   \label{eq:pdyn}
-    \Pd[j] = \max_{x=\beta_1,\dots \beta_2} (P\max[jx])  -  \min_{y=\Theta_1,\dots \Theta_2} (\Pidle[jy])
+    \Pd[j] = \max_{x=\beta_1,\dots \beta_2} (Pmax[jx])  -  \min_{y=\Theta_1,\dots \Theta_2} (\Pidle[jy])
 \end{equation}
 
 where $\Pd[j]$ is the dynamic power consumption for one core of node $j$, 
-$\lbrace \beta_1,\beta_2 \rbrace$ is the time interval for the measured peak power values, 
+$\lbrace \beta_1,\beta_2 \rbrace$ is the time interval for the measured maximum power values, 
 $\lbrace\Theta_1,\Theta_2\rbrace$ is the time interval for the measured  idle power values.
 Therefore, the dynamic power of one core is computed as the difference between the maximum 
-measured value in peak powers vector and the minimum measured value in the idle powers vector.
+measured value in maximum powers vector and the minimum measured value in the idle powers vector.
 
 On the other hand, the static power consumption by one core is a part of the measured idle power consumption of the node. Since in grid'5000 there is no way to measure precisely the consumed static power and in~\cite{Our_first_paper,pdsec2015,Rauber_Analytical.Modeling.for.Energy} it was assumed that  the static power  represents a ratio of the dynamic power, the value of the static power is assumed as  np[\%]{20} of dynamic power consumption of the core.
 
@@ -743,7 +740,7 @@ Table \ref{tab:sc} shows the number of nodes used from each cluster for each sce
   \label{fig:time_sen}
 \end{figure}
 
-The NAS parallel benchmarks are executed over these two platform
+The NAS parallel benchmarks are executed over these two platforms
  with different number of nodes, as in Table \ref{tab:sc}. 
 The overall energy consumption of all the benchmarks solving the class D instance and
 using the proposed frequency selection algorithm is measured 
@@ -762,8 +759,6 @@ The long distance communications between the two distributed sites increase the
 over one site with 16 and 32 nodes are also lower when  compared to those of the  two sites 
 scenario.
 
-
-
 However, the  execution times and the energy consumptions of EP and MG benchmarks, which have no or small communications, are not significantly affected 
  in both scenarios. Even when the number of nodes is doubled. On the other hand, the communications of the rest of the benchmarks increases when using long distance communications between two sites or increasing the number of computing nodes.
 
@@ -846,8 +841,159 @@ percentage. Finally, the best energy and performance tradeoff depends on the inc
 1) the computations to communications ratio, 2) the differences in computing powers 
 between the computing nodes and 3) the differences in static and the dynamic powers of the nodes.
 
-\subsection{The experimental results of multi-cores clusters}
-\label{sec.res}
+\subsection{The experimental results of multicores clusters}
+\label{sec.res-mc}
+The grid'5000 clusters have different number of cores embedded in their nodes
+as in the Table \ref{table:grid5000}. Moreover, the cores of each node are 
+connected via shared memory model, the data transfer between cores' local 
+memories achieved via the global memory \cite{rauber_book}. Therefore, in 
+this section the proposed scaling algorithm is implemented over the  grid'5000 
+clusters which are included multicores in the selected nodes as same as the 
+two previous platform scenarios that mentioned in the section \ref{sec.res}.
+The two platform scenarios, the two sites and one site scenarios,  with 32 
+nodes are reconfigured to used multicores for each node. For example if 
+the participating number of nodes from a certain cluster is equal to 12 nodes, 
+in the multicores scenario the selected nodes is equal to 3 nodes with using 
+4 cores for each of them to produced 12 cores. These scenarios with one  
+core and  multicores are  demonstrated in Table \ref{table:sen-mc}. 
+The energy consumptions and execution times of running the NAS parallel 
+benchmarks, class D, over these four different scenarios are represented 
+in the figures \ref{fig:eng-cons-mc} and \ref{fig:time-mc} respectively.
+The execution times of NAS  benchmarks over the one site multicores scenario 
+is higher than the execution time of those running over one site multicores scenario. 
+This because in the one site multicores scenario the communication is increased significantly,
+and all node's cores  share  the same node network link which increased 
+the communication times. While, the execution times of the NAS benchmarks  over 
+the two site  multicores scenario is less than those executed over the two 
+sites one core scenario. This because using multicores decrease the communications, 
+while the cores shared same nodes' link but the communications between the cores 
+are less than the communication times between the nodes over the long distance 
+networks, and thus the over all execution time decreased. Generally, executing 
+the NAS benchmarks over the one site one core gives smaller execution times 
+comparing to other scenarios. This because each node in this scenario has it's 
+dedicated network link that used independently by one core, while in the other 
+scenarios the communication times are higher when using long distance communication 
+link or using the  shared link communications between cores of each node. 
+On the other hand, the energy consumptions of the NAS benchmarks over the 
+one site one cores is less than the one site multicores scenario because 
+this scenario had less execution time as mentioned before. Also, in the 
+one site one core scenario the computations to communications ratio is 
+higher, then the new scaled frequencies are decreased the dynamic energy 
+consumption, because the dynamic power consumption are decreased exponentially 
+with the new frequency scaling factors. These experiments also showed, the energy 
+consumption and the execution times of EP and MG benchmarks over these four 
+scenarios are not change a lot, because there are no or small communications 
+ which are increase or decrease the static power consumptions. 
+The other benchmarks were showed that their energy consumptions and execution times 
+are changed according to the decreasing or increasing in the communication 
+times that are different from scenario to other or due to the amount of 
+communications in each of them.
+
+The energy saving percentages of all NAS benchmarks, as in figure 
+\ref{fig:eng-s-mc}, running over these four scenarios are presented. The figure 
+showed the energy saving percentages of NAS benchmarks over two sites multicores scenario is higher 
+than two sites once core scenario, this because the the computation 
+times in the two sites multicores scenario is higher than the computation times 
+of the two sites one core scenario, then the more reduction in the 
+dynamic energy can be obtained as mentioned previously. In contrast, in the one site one 
+core and one site multicores scenarios the energy saving percentages 
+are approximately equivalent, on average they are up to 25\%. This 
+because in the both scenarios there are a small difference  in the 
+computations to communications ratio, leading the proposed scaling algorithm 
+to selects the frequencies proportionally to these ratios and keeping 
+as much as possible the energy saving percentages the same. The 
+performance degradation percentages of NAS benchmarks are presented in
+figure \ref{fig:per-d-mc}. This figure indicates that performance 
+degradation percentages of running NAS benchmarks over two sites 
+multocores, on average is equal to 7\%,  gives more performance degradation percentage
+than two sites  one core scenario, which on average is equal to 4\%. 
+This because when using the two sites multicores scenario increased 
+the computations to communications ratio, which may be increased the effect
+on the overall execution time  when the proposed scaling algorithm is applied and scaling down the frequencies.  
+The inverse was happened when the benchmarks are executed  over one 
+site one core scenario their performance degradation percentages, on average
+is equal to 10\%, are higher than those executed over one sit one core, 
+which on average is equal to 7\%. This because  in one site 
+multicores scenario the computations to communications ratio is decreased
+as mentioned before, thus selecting new frequencies are less effect 
+on the overall execution time. The tradeoff distances of all NAS 
+benchmarks over all scenarios are presented in the figure \ref{fig:dist-mc}.
+These  tradeoff distances are used to verified which scenario is the best in term of 
+energy and performance ratio. The one sites multicores scenario is the best  scenario in term of
+energy and performance tradeoff, on average is equal to 17.6\%, when comparing to the one site one core 
+scenario, one average is equal to 15.3\%.  This because the one site multicores  scenario 
+has the same  energy saving percentages of the one site one core scenario but
+with less performance degradation. The two sites multicores scenario is gives better 
+energy and performance tradeoff, one average is equal to 14.7\%, than the two sites
+one core, on average is equal to 13.3\%.
+Finally, using multicore in both scenarios increased the energy and performance tradeoff 
+distance. This is because using multicores are increased the computations to communications 
+ratio in two sites scenario and thus the energy saving increased over the performance degradation, whereas  decreased this ratio 
+in one site scenario causing the performance degradation decreased over the energy saving.
+
+
+
+
+
+\begin{table}[]
+\centering
+\caption{The multicores scenarios}
+
+\begin{tabular}{|*{4}{c|}}
+\hline
+Scenario name                          & Cluster name & \begin{tabular}[c]{@{}c@{}}No. of  nodes\\ in each cluster\end{tabular} & 
+                                       \begin{tabular}[c]{@{}c@{}}No. of  cores\\ for each node\end{tabular}  \\ \hline
+\multirow{3}{*}{Two sites/ one core}   & Taurus       & 10              & 1                   \\ \cline{2-4}
+                                       & Graphene     & 10              & 1                   \\ \cline{2-4}
+                                       & Griffon      & 12              & 1                   \\ \hline
+\multirow{3}{*}{Two sites/ multicores} & Taurus       & 3               & 3 or 4              \\ \cline{2-4}
+                                       & Graphene     & 3               & 3 or 4              \\  \cline{2-4}
+                                       & Griffon      & 3               & 4                   \\ \hline
+\multirow{3}{*}{One site/ one core}    & Graphite     & 4               & 1                   \\  \cline{2-4}
+                                       & Graphene     & 12              & 1                   \\  \cline{2-4}
+                                       & Griffon      & 12              & 1                   \\ \hline
+\multirow{3}{*}{One site/ multicores}  & Graphite     & 3               & 3 or 4              \\  \cline{2-4}
+                                       & Graphene     & 3               & 3 or 4              \\  \cline{2-4}
+                                       & Griffon      & 3               & 4                   \\ \hline
+\end{tabular}
+\label{table:sen-mc}
+\end{table}
+
+\begin{figure}
+  \centering
+  \includegraphics[scale=0.5]{fig/eng_con.eps}
+  \caption{Comparing the  energy consumptions of running NAS benchmarks over one core and multicores scenarios }
+  \label{fig:eng-cons-mc}
+\end{figure}
+
+
+  \begin{figure}
+  \centering
+  \includegraphics[scale=0.5]{fig/time.eps}
+  \caption{Comparing the  execution times of running NAS benchmarks over one core and multicores scenarios }
+  \label{fig:time-mc}
+\end{figure}
+
+ \begin{figure}
+  \centering
+  \includegraphics[scale=0.5]{fig/eng_s_mc.eps}
+  \caption{The energy saving of running NAS benchmarks over one core and multicores scenarios }
+  \label{fig:eng-s-mc}
+\end{figure}
+
+\begin{figure}
+  \centering
+  \includegraphics[scale=0.5]{fig/per_d_mc.eps}
+  \caption{The performance degradation of running NAS benchmarks over one core and multicores scenarios }
+  \label{fig:per-d-mc}
+\end{figure}
+
+\begin{figure}
+  \centering
+  \includegraphics[scale=0.5]{fig/dist_mc.eps}
+  \caption{The tradeoff distance of running NAS benchmarks over one core and multicores scenarios }
+  \label{fig:dist-mc}
+\end{figure}
 
 \subsection{The results for different power consumption scenarios}
 \label{sec.compare}