1 \documentclass[conference]{IEEEtran}
3 \usepackage[T1]{fontenc}
4 \usepackage[utf8]{inputenc}
5 \usepackage[english]{babel}
6 \usepackage{algpseudocode}
12 \DeclareUrlCommand\email{\urlstyle{same}}
14 \usepackage[autolanguage,np]{numprint}
16 \renewcommand*\npunitcommand[1]{\text{#1}}
17 \npthousandthpartsep{}}
20 \usepackage[textsize=footnotesize]{todonotes}
21 \newcommand{\AG}[2][inline]{%
22 \todo[color=green!50,#1]{\sffamily\textbf{AG:} #2}\xspace}
23 \newcommand{\JC}[2][inline]{%
24 \todo[color=red!10,#1]{\sffamily\textbf{JC:} #2}\xspace}
26 \newcommand{\Xsub}[2]{\ensuremath{#1_\textit{#2}}}
28 \newcommand{\Dist}{\textit{Dist}}
29 \newcommand{\Eind}{\Xsub{E}{ind}}
30 \newcommand{\Enorm}{\Xsub{E}{Norm}}
31 \newcommand{\Eoriginal}{\Xsub{E}{Original}}
32 \newcommand{\Ereduced}{\Xsub{E}{Reduced}}
33 \newcommand{\Fdiff}{\Xsub{F}{diff}}
34 \newcommand{\Fmax}{\Xsub{F}{max}}
35 \newcommand{\Fnew}{\Xsub{F}{new}}
36 \newcommand{\Ileak}{\Xsub{I}{leak}}
37 \newcommand{\Kdesign}{\Xsub{K}{design}}
38 \newcommand{\MaxDist}{\textit{Max Dist}}
39 \newcommand{\Ntrans}{\Xsub{N}{trans}}
40 \newcommand{\Pdyn}{\Xsub{P}{dyn}}
41 \newcommand{\PnormInv}{\Xsub{P}{NormInv}}
42 \newcommand{\Pnorm}{\Xsub{P}{Norm}}
43 \newcommand{\Tnorm}{\Xsub{T}{Norm}}
44 \newcommand{\Pstates}{\Xsub{P}{states}}
45 \newcommand{\Pstatic}{\Xsub{P}{static}}
46 \newcommand{\Sopt}{\Xsub{S}{opt}}
47 \newcommand{\Tcomp}{\Xsub{T}{comp}}
48 \newcommand{\TmaxCommOld}{\Xsub{T}{Max Comm Old}}
49 \newcommand{\TmaxCompOld}{\Xsub{T}{Max Comp Old}}
50 \newcommand{\Tmax}{\Xsub{T}{max}}
51 \newcommand{\Tnew}{\Xsub{T}{New}}
52 \newcommand{\Told}{\Xsub{T}{Old}}
56 \title{Energy Consumption Reduction in heterogeneous architecture using DVFS}
67 University of Franche-Comté\\
68 IUT de Belfort-Montbéliard,
69 19 avenue du Maréchal Juin, BP 527, 90016 Belfort cedex, France\\
70 % Telephone: \mbox{+33 3 84 58 77 86}, % Raphaël
71 % Fax: \mbox{+33 3 84 58 77 81}\\ % Dept Info
72 Email: \email{{jean-claude.charr,raphael.couturier,ahmed.fanfakh_badri_muslim,arnaud.giersch}@univ-fcomte.fr}
82 \section{Introduction}
86 \section{Related works}
93 \section{The performance and energy consumption measurements on heterogeneous architecture}
96 % \JC{The whole subsection ``Parallel Tasks Execution on Homogeneous Platform'',
97 % can be deleted if we need space, we can just say we are interested in this
98 % paper in homogeneous clusters}
100 \subsection{The execution time of message passing distributed iterative applications on a heterogeneous platform}
102 In this paper, we are interested in reducing the energy consumption of message
103 passing distributed iterative synchronous applications running over
104 heterogeneous platforms. We define a heterogeneous platform as a collection of
105 heterogeneous computing nodes interconnected via a high speed homogeneous
106 network. Therefore, each node has different characteristics such as computing
107 power (FLOPS), energy consumption, CPU's frequency range, \dots{} but they all
108 have the same network bandwidth and latency.
113 \includegraphics[scale=0.6]{fig/commtasks}
114 \caption{Parallel tasks on a heterogeneous platform}
118 The overall execution time of a distributed iterative synchronous application over a heterogeneous platform consists of the sum of the computation time and the communication time for every iteration on a node. However, due to the heterogeneous computation power of the computing nodes, slack times might occur when fast nodes have to
119 wait, during synchronous communications, for the slower nodes to finish their computations (see Figure~(\ref{fig:heter})).
120 Therefore, the overall execution time of the program is the execution time of the slowest
121 task which have the highest computation time and no slack time.
123 Dynamic Voltage and Frequency Scaling (DVFS) is a process, implemented in modern processors, that reduces the energy consumption
124 of a CPU by scaling down its voltage and frequency. Since DVFS lowers the frequency of a CPU and consequently its computing power, the execution time of a program running over that scaled down processor might increase, especially if the program is compute bound. The frequency reduction process can be expressed by the scaling factor S which is the ratio between the maximum and the new frequency of a CPU as in EQ (\ref{eq:s}).
127 S = \frac{F_\textit{max}}{F_\textit{new}}
129 The execution time of a compute bound sequential program is linearly proportional to the frequency scaling factor $S$.
130 On the other hand, message passing distributed applications consist of two parts: computation and communication. The execution time of the computation part is linearly proportional to the frequency scaling factor $S$ but the communication time is not affected by the scaling factor because the processors involved remain idle during the communications~\cite{17}. The communication time for a task is the summation of periods of time that begin with an MPI call for sending or receiving a message till the message is synchronously sent or received.
132 Since in a heterogeneous platform, each node has different characteristics,
133 especially different frequency gears, when applying DVFS operations on these
134 nodes, they may get different scaling factors represented by a scaling vector:
135 $(S_1, S_2,\dots, S_N)$ where $S_i$ is the scaling factor of processor $i$. To
136 be able to predict the execution time of message passing synchronous iterative
137 applications running over a heterogeneous platform, for different vectors of
138 scaling factors, the communication time and the computation time for all the
139 tasks must be measured during the first iteration before applying any DVFS
140 operation. Then the execution time for one iteration of the application with any
141 vector of scaling factors can be predicted using EQ (\ref{eq:perf}).
144 \textit T_\textit{new} =
145 \max_{i=1,2,\dots,N} (TcpOld_{i} \cdot S_{i}) + TcmOld_{j}
147 where $TcpOld_i$ is the computation time of processor $i$ during the first iteration and $TcmOld_j$ is the communication time of the slowest processor $j$.
148 The model computes the maximum computation time
149 with scaling factor from each node added to the communication time of the slowest node, it means only the
150 communication time without any slack time.
152 This prediction model is based on our model for predicting the execution time of message passing distributed applications for homogeneous architectures~\cite{45}. The execution time prediction model is used in our method for optimizing both energy consumption and performance of iterative methods, which is presented in the following sections.
155 \subsection{Energy model for heterogeneous platform}
157 Many researchers~\cite{9,3,15,26} divide the power consumed by a processor into
158 two power metrics: the static and the dynamic power. While the first one is
159 consumed as long as the computing unit is turned on, the latter is only consumed during
160 computation times. The dynamic power $P_{d}$ is related to the switching
161 activity $\alpha$, load capacitance $C_L$, the supply voltage $V$ and
162 operational frequency $F$, as shown in EQ(\ref{eq:pd}).
165 P_\textit{d} = \alpha \cdot C_L \cdot V^2 \cdot F
167 The static power $P_{s}$ captures the leakage power as follows:
170 P_\textit{s} = V \cdot N_{trans} \cdot K_{design} \cdot I_{leak}
172 where V is the supply voltage, $N_{trans}$ is the number of transistors,
173 $K_{design}$ is a design dependent parameter and $I_{leak}$ is a
174 technology-dependent parameter. The energy consumed by an individual processor
175 to execute a given program can be computed as:
178 E_\textit{ind} = P_\textit{d} \cdot T_{cp} + P_\textit{s} \cdot T
180 where $T$ is the execution time of the program, $T_{cp}$ is the computation
181 time and $T_{cp} \leq T$. $T_{cp}$ may be equal to $T$ if there is no
182 communication and no slack time.
184 The main objective of DVFS operation is to
185 reduce the overall energy consumption~\cite{37}. The operational frequency $F$
186 depends linearly on the supply voltage $V$, i.e., $V = \beta \cdot F$ with some
187 constant $\beta$. This equation is used to study the change of the dynamic
188 voltage with respect to various frequency values in~\cite{3}. The reduction
189 process of the frequency can be expressed by the scaling factor $S$ which is the
190 ratio between the maximum and the new frequency as in EQ~(\ref{eq:s}).
191 The CPU governors are power schemes supplied by the operating
192 system's kernel to lower a core's frequency. we can calculate the new frequency
193 $F_{new}$ from EQ(\ref{eq:s}) as follow:
196 F_\textit{new} = S^{-1} \cdot F_\textit{max}
198 Replacing $F_{new}$ in EQ(\ref{eq:pd}) as in EQ(\ref{eq:fnew}) gives the following equation for dynamic
202 {P}_\textit{dNew} = \alpha \cdot C_L \cdot V^2 \cdot F_{new} = \alpha \cdot C_L \cdot \beta^2 \cdot F_{new}^3 \\
203 {} = \alpha \cdot C_L \cdot V^2 \cdot F \cdot S^{-3} = P_{dOld} \cdot S^{-3}
205 where $ {P}_\textit{dNew}$ and $P_{dOld}$ are the dynamic power consumed with the new frequency and the maximum frequency respectively.
207 According to EQ(\ref{eq:pdnew}) the dynamic power is reduced by a factor of $S^{-3}$ when
208 reducing the frequency by a factor of $S$~\cite{3}. Since the FLOPS of a CPU is proportional to the frequency of a CPU, the computation time is increased proportionally to $S$. The new dynamic energy is the dynamic power multiplied by the new time of computation and is given by the following equation:
211 E_\textit{dNew} = P_{dOld} \cdot S^{-3} \cdot (T_{cp} \cdot S)= S^{-2}\cdot P_{dOld} \cdot T_{cp}
213 The static power is related to the power leakage of the CPU and is consumed during computation and even when idle. As in~\cite{3,46}, we assume that the static power of a processor is constant during idle and computation periods, and for all its available frequencies.
214 The static energy is the static power multiplied by the execution time of the program. According to the execution time model in EQ(\ref{eq:perf}),
215 the execution time of the program is the summation of the computation and the communication times. The computation time is linearly related
216 to the frequency scaling factor, while this scaling factor does not affect the communication time. The static energy
217 of a processor after scaling its frequency is computed as follows:
220 E_\textit{s} = P_\textit{s} \cdot (T_{cp} \cdot S + T_{cm})
223 In the considered heterogeneous platform, each processor $i$ might have different dynamic and static powers, noted as $P_{di}$ and $P_{si}$ respectively. Therefore, even if the distributed message passing iterative application is load balanced, the computation time of each CPU $i$ noted $T_{cpi}$ might be different and different frequency scaling factors might be computed in order to decrease the overall energy consumption of the application and reduce the slack times. The communication time of a processor $i$ is noted as $T_{cmi}$ and could contain slack times if it is communicating with slower nodes, see figure(\ref{fig:heter}). Therefore, all nodes do not have equal communication times. While the dynamic energy is computed according to the frequency scaling factor and the dynamic power of each node as in EQ(\ref{eq:Edyn}), the static energy is computed as the sum of the execution time of each processor multiplied by its static power. The overall energy consumption of a message passing distributed application executed over a heterogeneous platform is the summation of all dynamic and static energies for each processor. It is computed as follows:
226 E = \sum_{i=1}^{N} {(S_i^{-2} \cdot P_{di} \cdot T_{cpi})} + {} \\
227 \sum_{i=1}^{N} (P_{si} \cdot (\max_{i=1,2,\dots,N} (T_{cpi} \cdot S_{i}) +
228 \min_{i=1,2,\dots,N} {T_{cmi}))}
231 Reducing the the frequencies of the processors according to the vector of
232 scaling factors $(S_1, S_2,\dots, S_N)$ may degrade the performance of the
233 application and thus, increase the static energy because the execution time is
236 \section{Optimization of both energy consumption and performance}
239 Using the lowest frequency for each processor does not necessarily gives the most energy efficient execution of an application. Indeed, even though the dynamic power is reduced while scaling down the frequency of a processor, its computation power is proportionally decreased and thus the execution time might be drastically increased during which dynamic and static powers are being consumed. Therefore, it might cancel any gains achieved by scaling down the frequency of all nodes to the minimum and the overall energy consumption of the application might not be the optimal one. It is not trivial to select the appropriate frequency scaling factor for each processor while considering the characteristics of each processor (computation power, range of frequencies, dynamic and static powers) and the task executed (computation/communication ratio) in order to reduce the overall energy consumption and not significantly increase the execution time. In
240 our previous work~\cite{45}, we proposed a method that selects the optimal
241 frequency scaling factor for a homogeneous cluster executing a message passing iterative synchronous application while giving the best trade-off
242 between the energy consumption and the performance for such applications. In this work we are interested in
243 heterogeneous clusters as described above. Due to the heterogeneity of the processors, not one but a set of scaling factors should be selected and it must give the best trade-off between energy
244 consumption and performance.
246 The relation between the energy consumption and the execution
247 time for an application is complex and nonlinear, Thus, unlike the relation between the performance
248 and the scaling factor, the relation of the energy with the frequency scaling
249 factors is nonlinear, for more details refer to~\cite{17}. Moreover, they are
250 not measured using the same metric. To solve this problem, we normalize the
251 execution time by computing the ratio between the new execution time (after scaling down the frequencies of some processors) and the initial one (with maximum frequency for all nodes,) as follows:
254 P_\textit{Norm} = \frac{T_\textit{New}}{T_\textit{Old}}\\
255 {} = \frac{ \max_{i=1,2,\dots,N} (Tcp_{i} \cdot S_{i}) +\min_{i=1,2,\dots,N} {Tcm_{i}}}
256 {\max_{i=1,2,\dots,N}{(Tcp_i+Tcm_i)}}
260 In the same way, we normalize the energy by computing the ratio between the consumed energy while scaling down the frequency and the consumed energy with maximum frequency for all nodes:
263 E_\textit{Norm} = \frac{E_\textit{Reduced}}{E_\textit{Original}} \\
264 {} = \frac{ \sum_{i=1}^{N}{(S_i^{-2} \cdot Pd_i \cdot Tcp_i)} +
265 \sum_{i=1}^{N} {(Ps_i \cdot T_{New})}}{\sum_{i=1}^{N}{( Pd_i \cdot Tcp_i)} +
266 \sum_{i=1}^{N} {(Ps_i \cdot T_{Old})}}
268 Where $T_{New}$ and $T_{Old}$ are computed as in EQ(\ref{eq:pnorm}).
271 goal is to optimize the energy and execution time at the same time, the normalized energy and execution time curves are not in the same direction. According
272 to the equations~(\ref{eq:enorm}) and~(\ref{eq:pnorm}), the set of frequency
273 scaling factors $S_1,S_2,\dots,S_N$ reduce both the energy and the execution
274 time simultaneously. But the main objective is to produce maximum energy
275 reduction with minimum execution time reduction.
277 Many researchers used
278 different strategies to solve this nonlinear problem for example
279 in~\cite{19,42}, their methods add big overheads to the algorithm to select the
280 suitable frequency. In this paper we present a method to find the optimal
281 set of frequency scaling factors to simultaneously optimize both energy and execution time
282 without adding a big overhead. \textbf{put the last two phrases in the related work section}
285 Our solution for this problem is
286 to make the optimization process for energy and execution time follow the same
287 direction. Therefore, we inverse the equation of the normalized execution time which gives
288 the normalized performance equation, as follows:
291 P_\textit{Norm} = \frac{T_\textit{Old}}{T_\textit{New}}\\
292 = \frac{\max_{i=1,2,\dots,N}{(Tcp_i+Tcm_i)}}
293 { \max_{i=1,2,\dots,N} (Tcp_{i} \cdot S_{i}) +\min_{i=1,2,\dots,N} {Tcm_{i}}}
299 \subfloat[Homogeneous platform]{%
300 \includegraphics[width=.22\textwidth]{fig/homo}\label{fig:r1}}%
302 \subfloat[Heterogeneous platform]{%
303 \includegraphics[width=.22\textwidth]{fig/heter}\label{fig:r2}}
305 \caption{The energy and performance relation}
308 Then, we can model our objective function as finding the maximum distance
309 between the energy curve EQ~(\ref{eq:enorm}) and the performance
310 curve EQ~(\ref{eq:pnorm_inv}) over all available sets of scaling factors. This
311 represents the minimum energy consumption with minimum execution time (better
312 performance) at the same time, see figure~(\ref{fig:r1}) or figure~(\ref{fig:r2}) . Then our objective
313 function has the following form:
317 \max_{i=1,\dots F, j=1,\dots,N}
318 (\overbrace{P_\textit{Norm}(S_{ij})}^{\text{Maximize}} -
319 \overbrace{E_\textit{Norm}(S_{ij})}^{\text{Minimize}} )
321 where $N$ is the number of nodes and $F$ is the number of available frequencies for each nodes.
322 Then we can select the optimal set of scaling factors that satisfies EQ~(\ref{eq:max}). Our objective function can
323 work with any energy model or any power values for each node (static and dynamic powers).
324 However, the most energy reduction gain can be achieved the energy curve has a convex form as shown in~\cite{15,3,19}.
326 \section{The heterogeneous scaling algorithm }
329 In this section we proposed an heterogeneous scaling algorithm,
330 (figure~\ref{HSA}), that selects the optimal set of scaling factors from each
331 node. The algorithm is numerates the suitable range of available scaling
332 factors for each node in the heterogeneous cluster, returns a set of optimal
333 frequency scaling factors for each node. Using heterogeneous cluster is produces
334 different workloads for each node. Therefore, the fastest nodes waiting at the
335 barrier for the slowest nodes to finish there work as in figure
336 (\ref{fig:heter}). Our algorithm takes into account these imbalanced workloads
337 when is starts to search for selecting the best scaling factors. So, the
338 algorithm is selecting the initial frequencies values for each node proportional
339 to the times of computations that gathered from the first iteration. As an
340 example in figure (\ref{fig:st_freq}), the algorithm don't test the first
341 frequencies of the fastest nodes until it converge their frequencies to the
342 frequency of the slowest node. If the algorithm is starts test changing the
343 frequency of the slowest nodes from beginning, we are loosing performance and
344 then not selecting the best trade-off (the distance). This case will be similar
345 to the homogeneous cluster when all nodes scales their frequencies together from
346 the beginning. In this case there is a small distance between energy and
347 performance curves, for example see the figure(\ref{fig:r1}). Then the
348 algorithm searching for optimal frequency scaling factor from the selected
349 frequencies until the last available ones.
352 \includegraphics[scale=0.5]{fig/start_freq}
353 \caption{Selecting the initial frequencies}
358 To compute the initial frequencies, the algorithm firstly needs to compute the computation scaling factors $Scp_i$ for each node. Each one of these factors represent a ratio between the computation time of the slowest node and the computation time of the node $i$ as follow:
361 Scp_{i} = \frac{\max_{i=1,2,\dots,N}(Tcp_i)}{Tcp_i}
363 Depending on the initial computation scaling factors EQ(\ref{eq:Scp}), the algorithm computes the initial frequencies for all nodes as a ratio between the
364 maximum frequency of node $i$ and the computation scaling factor $Scp_i$ as follow:
367 F_{i} = \frac{Fmax_i}{Scp_i},~{i=1,2,\cdots,N}
370 \begin{algorithmic}[1]
374 \item[$Tcp_i$] array of all computation times for all nodes during one iteration and with highest frequency.
375 \item[$Tcm_i$] array of all communication times for all nodes during one iteration and with highest frequency.
376 \item[$Fmax_i$] array of the maximum frequencies for all nodes.
377 \item[$Pd_i$] array of the dynamic powers for all nodes.
378 \item[$Ps_i$] array of the static powers for all nodes.
379 \item[$Fdiff_i$] array of the difference between two successive frequencies for all nodes.
381 \Ensure $Sopt_1, \dots, Sopt_N$ is a set of optimal scaling factors
383 \State $ Scp_i \gets \frac{\max_{i=1,2,\dots,N}(Tcp_i)}{Tcp_i} $
384 \State $F_{i} \gets \frac{Fmax_i}{Scp_i},~{i=1,2,\cdots,N}$
385 \State Round the computed initial frequencies $F_i$ to the closest one available in each node.
386 \If{(not the first frequency)}
387 \State $F_i \gets F_i+Fdiff_i,~i=1,\dots,N.$
389 \State $T_\textit{Old} \gets max_{~i=1,\dots,N } (Tcp_i+Tcm_i)$
390 \State $E_\textit{Original} \gets \sum_{i=1}^{N}{( Pd_i \cdot Tcp_i)} +\sum_{i=1}^{N} {(Ps_i \cdot T_{Old})}$
391 \State $Dist \gets 0$
392 \State $Sopt_{i} \gets 1,~i=1,\dots,N. $
393 \While {(all nodes not reach their minimum frequency)}
394 \If{(not the last freq. \textbf{and} not the slowest node)}
395 \State $F_i \gets F_i - Fdiff_i,~i=1,\dots,N.$
396 \State $S_i \gets \frac{Fmax_i}{F_i},~i=1,\dots,N.$
398 \State $T_{New} \gets max_\textit{~i=1,\dots,N} (Tcp_{i} \cdot S_{i}) + min_\textit{~i=1,\dots,N}(Tcm_i) $
399 \State $E_\textit{Reduced} \gets \sum_{i=1}^{N}{(S_i^{-2} \cdot Pd_i \cdot Tcp_i)} + $ \hspace*{43 mm}
400 $\sum_{i=1}^{N} {(Ps_i \cdot T_{New})} $
401 \State $ P_\textit{Norm} \gets \frac{T_\textit{Old}}{T_\textit{New}}$
402 \State $E_\textit{Norm}\gets \frac{E_\textit{Reduced}}{E_\textit{Original}}$
403 \If{$(\Pnorm - \Enorm > \Dist)$}
404 \State $Sopt_{i} \gets S_{i},~i=1,\dots,N. $
405 \State $\Dist \gets \Pnorm - \Enorm$
408 \State Return $Sopt_1,Sopt_2,\dots,Sopt_N$
410 \caption{Heterogeneous scaling algorithm}
413 When the initial frequencies are computed the algorithm numerates all available
414 scaling factors starting from these frequencies until all nodes reach their
415 minimum frequencies. At each iteration the algorithm remains the frequency of
416 the slowest node without change and scaling the frequency of the other
417 nodes. This is gives better performance and energy trade-off. The proposed
418 algorithm works online during the execution time of the MPI program. Its
419 returns a set of optimal frequency scaling factors $Sopt_i$ depending on the
420 objective function EQ(\ref{eq:max}). The program changes the new frequencies of
421 the CPUs according to the computed scaling factors. This algorithm has a small
422 execution time: for an heterogeneous cluster composed of four different types of
423 nodes having the characteristics presented in table~(\ref{table:platform}), it
424 takes \np[ms]{0.04} on average for 4 nodes and \np[ms]{0.1} on average for 128
425 nodes. The algorithm complexity is $O(F\cdot (N \cdot4) )$, where $F$ is the
426 number of iterations and $N$ is the number of computing nodes. The algorithm
427 needs on average from 12 to 20 iterations for all the NAS benchmark on class C
428 to selects the best set of frequency scaling factors. Its called just once
429 during the execution of the program. The DVFS figure~(\ref{dvfs}) shows where
430 and when the algorithm is called in the MPI program.
432 \begin{algorithmic}[1]
434 \For {$k=1$ to \textit{some iterations}}
435 \State Computations section.
436 \State Communications section.
438 \State Gather all times of computation and\newline\hspace*{3em}%
439 communication from each node.
440 \State Call algorithm from Figure~\ref{HSA} with these times.
441 \State Compute the new frequencies from the\newline\hspace*{3em}%
442 returned optimal scaling factors.
443 \State Set the new frequencies to nodes.
447 \caption{DVFS algorithm}
451 \section{Experimental results}
454 The experiments of this work are executed on the simulator SimGrid/SMPI
455 v3.10~\cite{casanova+giersch+legrand+al.2014.versatile}. We configure the
456 simulator to use a heterogeneous cluster with one core per node. The proposed
457 heterogeneous cluster has four different types of nodes. Each node in cluster
458 has different characteristics such as the maximum frequency speed, the number of
459 available frequencies and dynamic and static powers values, see table
460 (\ref{table:platform}). These different types of processing nodes simulate some
461 real Intel processors. The maximum number of nodes that supported by the cluster
462 is 144 nodes according to characteristics of some MPI programs of the NAS
463 benchmarks that used. We are use the same number from each type of nodes when
464 running the MPI programs, for example if we execute the program on 8 node, there
465 are 2 nodes from each type participating in the computing. The dynamic and
466 static power values is different from one type to other. Each node has a dynamic
467 and static power values proportional to their performance/GFlops, for more
468 details see the Intel data sheets in \cite{47}. Each node has a percentage of
469 80\% for dynamic power and 20\% for static power from the hole power
470 consumption, the same assumption is made in \cite{45,3}. These nodes are
471 connected via an Ethernet network with 1 Gbit/s bandwidth.
473 \caption{Heterogeneous nodes characteristics}
476 \begin{tabular}{|*{7}{l|}}
478 Node & Similar & Max & Min & Diff. & Dynamic & Static \\
479 type & to & Freq. GHz & Freq. GHz & Freq GHz & power & power \\
481 1 & core-i3 & 2.5 & 1.2 & 0.1 & 20~w &4~w \\
484 2 & Xeon & 2.66 & 1.6 & 0.133 & 25~w &5~w \\
487 3 & core-i5 & 2.9 & 1.2 & 0.1 & 30~w &6~w \\
490 4 & core-i7 & 3.4 & 1.6 & 0.133 & 35~w &7~w \\
494 \label{table:platform}
498 %\subsection{Performance prediction verification}
501 \subsection{The experimental results of the scaling algorithm}
504 The proposed algorithm was applied to seven MPI programs of the NAS benchmarks (EP, CG, MG, FT, BT, LU and SP) NPB v3.
505 \cite{44}, which were run with three classes (A, B and C).
506 In this experiments we are focus on running of the class C, the biggest class compared to A and B, on different number of
507 nodes, from 4 to 128 or 144 nodes according to the type of the MPI program. Depending on the proposed energy consumption model EQ(\ref{eq:energy}),
508 we are measure the energy consumption for all NAS MPI programs. The dynamic and static power values used under the same assumption used by \cite{45,3}. We used a percentage of 80\% for dynamic power from all power consumption of the CPU and 20\% for static power. The heterogeneous nodes in table (\ref{table:platform}) have different simulated performance, ranked from the node of type 1 with smaller performance/GFlops to the highest performance/GFlops for node 4. Therefore, the power values used proportionally increased from node 1 to node 4 that with highest performance. Then we used an assumption that the power consumption increases linearly with the performance/GFlops of the processor see \cite{48}.
511 \caption{Running NAS benchmarks on 4 nodes }
514 \begin{tabular}{|*{7}{l|}}
516 Method & Execution & Energy & Energy & Performance & Distance \\
517 name & time/s & consumption/J & saving\% & degradation\% & \\
519 CG & 64.64 & 3560.39 &34.16 &6.72 &27.44 \\
521 MG & 18.89 & 1074.87 &35.37 &4.34 &31.03 \\
523 EP &79.73 &5521.04 &26.83 &3.04 &23.79 \\
525 LU &308.65 &21126.00 &34.00 &6.16 &27.84 \\
527 BT &360.12 &21505.55 &35.36 &8.49 &26.87 \\
529 SP &234.24 &13572.16 &35.22 &5.70 &29.52 \\
531 FT &81.58 &4151.48 &35.58 &0.99 &34.59 \\
538 \caption{Running NAS benchmarks on 8 and 9 nodes }
541 \begin{tabular}{|*{7}{l|}}
543 Method & Execution & Energy & Energy & Performance & Distance \\
544 name & time/s & consumption/J & saving\% & degradation\% & \\
546 CG &36.11 &3263.49 &31.25 &7.12 &24.13 \\
548 MG &8.99 &953.39 &33.78 &6.41 &27.37 \\
550 EP &40.39 &5652.81 &27.04 &0.49 &26.55 \\
552 LU &218.79 &36149.77 &28.23 &0.01 &28.22 \\
554 BT &166.89 &23207.42 &32.32 &7.89 &24.43 \\
556 SP &104.73 &18414.62 &24.73 &2.78 &21.95 \\
558 FT &51.10 &4913.26 &31.02 &2.54 &28.48 \\
565 \caption{Running NAS benchmarks on 16 nodes }
568 \begin{tabular}{|*{7}{l|}}
570 Method & Execution & Energy & Energy & Performance & Distance \\
571 name & time/s & consumption/J & saving\% & degradation\% & \\
573 CG &31.74 &4373.90 &26.29 &9.57 &16.72 \\
575 MG &5.71 &1076.19 &32.49 &6.05 &26.44 \\
577 EP &20.11 &5638.49 &26.85 &0.56 &26.29 \\
579 LU &144.13 &42529.06 &28.80 &6.56 &22.24 \\
581 BT &97.29 &22813.86 &34.95 &5.80 &29.15 \\
583 SP &66.49 &20821.67 &22.49 &3.82 &18.67 \\
585 FT &37.01 &5505.60 &31.59 &6.48 &25.11 \\
588 \label{table:res_16n}
592 \caption{Running NAS benchmarks on 32 and 36 nodes }
595 \begin{tabular}{|*{7}{l|}}
597 Method & Execution & Energy & Energy & Performance & Distance \\
598 name & time/s & consumption/J & saving\% & degradation\% & \\
600 CG &32.35 &6704.21 &16.15 &5.30 &10.85 \\
602 MG &4.30 &1355.58 &28.93 &8.85 &20.08 \\
604 EP &9.96 &5519.68 &26.98 &0.02 &26.96 \\
606 LU &99.93 &67463.43 &23.60 &2.45 &21.15 \\
608 BT &48.61 &23796.97 &34.62 &5.83 &28.79 \\
610 SP &46.01 &27007.43 &22.72 &3.45 &19.27 \\
612 FT &28.06 &7142.69 &23.09 &2.90 &20.19 \\
615 \label{table:res_32n}
619 \caption{Running NAS benchmarks on 64 nodes }
622 \begin{tabular}{|*{7}{l|}}
624 Method & Execution & Energy & Energy & Performance & Distance \\
625 name & time/s & consumption/J & saving\% & degradation\% & \\
627 CG &46.65 &17521.83 &8.13 &1.68 &6.45 \\
629 MG &3.27 &1534.70 &29.27 &14.35 &14.92 \\
631 EP &5.05 &5471.1084 &27.12 &3.11 &24.01 \\
633 LU &73.92 &101339.16 &21.96 &3.67 &18.29 \\
635 BT &39.99 &27166.71 &32.02 &12.28 &19.74 \\
637 SP &52.00 &49099.28 &24.84 &0.03 &24.81 \\
639 FT &25.97 &10416.82 &20.15 &4.87 &15.28 \\
642 \label{table:res_64n}
647 \caption{Running NAS benchmarks on 128 and 144 nodes }
650 \begin{tabular}{|*{7}{l|}}
652 Method & Execution & Energy & Energy & Performance & Distance \\
653 name & time/s & consumption/J & saving\% & degradation\% & \\
655 CG &56.92 &41163.36 &4.00 &1.10 &2.90 \\
657 MG &3.55 &2843.33 &18.77 &10.38 &8.39 \\
659 EP &2.67 &5669.66 &27.09 &0.03 &27.06 \\
661 LU &51.23 &144471.90 &16.67 &2.36 &14.31 \\
663 BT &37.96 &44243.82 &23.18 &1.28 &21.90 \\
665 SP &64.53 &115409.71 &26.72 &0.05 &26.67 \\
667 FT &25.51 &18808.72 &12.85 &2.84 &10.01 \\
670 \label{table:res_128n}
673 The results of applying the proposed scaling algorithm to NAS benchmarks is demonstrated in tables (\ref{table:res_4n}, \ref{table:res_8n}, \ref{table:res_16n},
674 \ref{table:res_32n}, \ref{table:res_64n} and \ref{table:res_128n}). These tables show the results for running the NAS benchmarks on different number of nodes. In general the energy saving percent is decreased when the number of the computing nodes is increased. While the distance is decreased by the same direction. This because when we are run the MPI programs on a big number of nodes the communications is biggest than the computations, so the static energy is increased linearly to these times. The tables also show that performance degradation percent still approximately the same or decreased a little when the number of computing nodes is increased. This gives good a prove that the proposed algorithm keeping as mush as possible the performance degradation.
678 \subfloat[CG, MG, LU and FT Benchmarks]{%
679 \includegraphics[width=.23185\textwidth]{fig/avg_eq}\label{fig:avg_eq}}%
681 \subfloat[BT and SP benchmarks]{%
682 \includegraphics[width=.23185\textwidth]{fig/avg_neq}\label{fig:avg_neq}}
684 \caption{The average of energy and performance for all NAS benchmarks running with difference number of nodes}
687 In the NAS benchmarks there are some programs executed on different number of
688 nodes. The benchmarks CG, MG, LU and FT executed on 2 to a power of (1, 2, 4, 8,
689 \dots{}) of nodes. The other benchmarks such as BT and SP executed on 2 to a
690 power of (1, 2, 4, 9, \dots{}) of nodes. We are take the average of energy
691 saving, performance degradation and distances for all results of NAS
692 benchmarks. The average of these three objectives are plotted to the number of
693 nodes as in plots (\ref{fig:avg_eq} and \ref{fig:avg_neq}). In CG, MG, LU, and
694 FT benchmarks the average of energy saving is decreased when the number of nodes
695 is increased due to the increasing in the communication times as mentioned
696 before. Thus, the average of distances (our objective function) is decreased
697 linearly with energy saving while keeping the average of performance degradation
698 the same. In BT and SP benchmarks, the average of energy saving is not decreased
699 significantly compare to other benchmarks when the number of nodes is
700 increased. Nevertheless, the average of performance degradation approximately
701 still the same ratio. This difference is depends on the characteristics of the
702 benchmarks such as the computation to communication ratio that has.
704 \subsection{The results for different powers scenarios}
706 The results of the previous section are obtained using a percentage of 80\% for
707 dynamic power and 20\% for static power of total power consumption. In this
708 section we are change these ratio by using two others scenarios. Because is
709 interested to measure the ability of the proposed algorithm to changes it
710 behavior when these power ratios are changed. In fact, we are use two different
711 scenarios for dynamic and static power ratios in addition to the previous
712 scenario in section (\ref{sec.res}). Therefore, we have three different
713 scenarios for three different dynamic and static power ratios refer to as:
714 70\%-20\%, 80\%-20\% and 90\%-10\% scenario. The results of these scenarios
715 running NAS benchmarks class C on 8 or 9 nodes are place in the tables
716 (\ref{table:res_s1} and \ref{table:res_s2}).
719 \caption{The results of 70\%-30\% powers scenario}
722 \begin{tabular}{|*{6}{l|}}
724 Method & Energy & Energy & Performance & Distance \\
725 name & consumption/J & saving\% & degradation\% & \\
727 CG &4144.21 &22.42 &7.72 &14.70 \\
729 MG &1133.23 &24.50 &5.34 &19.16 \\
731 EP &6170.30 &16.19 &0.02 &16.17 \\
733 LU &39477.28 &20.43 &0.07 &20.36 \\
735 BT &26169.55 &25.34 &6.62 &18.71 \\
737 SP &19620.09 &19.32 &3.66 &15.66 \\
739 FT &6094.07 &23.17 &0.36 &22.81 \\
748 \caption{The results of 90\%-10\% powers scenario}
751 \begin{tabular}{|*{6}{l|}}
753 Method & Energy & Energy & Performance & Distance \\
754 name & consumption/J & saving\% & degradation\% & \\
756 CG &2812.38 &36.36 &6.80 &29.56 \\
758 MG &825.427 &38.35 &6.41 &31.94 \\
760 EP &5281.62 &35.02 &2.68 &32.34 \\
762 LU &31611.28 &39.15 &3.51 &35.64 \\
764 BT &21296.46 &36.70 &6.60 &30.10 \\
766 SP &15183.42 &35.19 &11.76 &23.43 \\
768 FT &3856.54 &40.80 &5.67 &35.13 \\
777 \subfloat[Comparison the average of the results on 8 nodes]{%
778 \includegraphics[width=.22\textwidth]{fig/sen_comp}\label{fig:sen_comp}}%
780 \subfloat[Comparison the selected frequency scaling factors for 8 nodes]{%
781 \includegraphics[width=.24\textwidth]{fig/three_scenarios}\label{fig:scales_comp}}
783 \caption{The comparison of the three power scenarios}
786 To compare the results of these three powers scenarios, we are take the average of the performance degradation, the energy saving and the distances for all NAS benchmarks running on 8 or 9 nodes of class C, as in figure (\ref{fig:sen_comp}). Thus, according to the average of the results, the energy saving ratio is increased when using the a higher percentage for dynamic power (e.g. 90\%-10\% scenario). While the average of energy saving is decreased in 70\%-30\% scenario.
787 Because the static energy consumption is increase. Moreover, the average of distances is more related to energy saving changes. The average of the performance degradation is decreased when using a higher ratio for static power (e.g. 70\%-30\% scenario and 80\%-20\% scenario). The raison behind these relations, that the proposed algorithm optimize both energy consumption and performance in the same time. Therefore, when using a higher ratio for dynamic power the algorithm selecting bigger frequency scaling factors values, more energy saving versus more performance degradation, for example see the figure (\ref{fig:scales_comp}). The inverse happen when using a higher ratio for static power, the algorithm proportionally selects a smaller scaling values, less energy saving versus less performance degradation. This is because the
788 algorithm also keeps as much as possible the static energy consumption that is always related to execution time.
790 \subsection{The verifications of the proposed method}
792 The precision of the proposed algorithm mainly depends on the execution time prediction model and the energy model. The energy model is significantly depends on the execution time model EQ(\ref{eq:perf}), that the energy static related linearly. So, we are compare the predicted execution time with the real execution time (Simgrid time) values that gathered offline for the NAS benchmarks class B executed on 8 or 9 nodes. The execution time model can predicts
793 the real execution time by maximum normalized error 0.03 of all NAS benchmarks. The second verification that we are make is for the scaling algorithm to prove its ability to selects the best set of frequency scaling factors. Therefore, we are expand the algorithm to test at each iteration the frequency scaling factor of the slowest node with the all scaling factors available of the other nodes. This version of the algorithm is applied to different NAS benchmarks classes with different number of nodes. The results from the two algorithms is identical. While the proposed algorithm is runs faster, 10 times faster on average than the expanded algorithm.
799 \section*{Acknowledgment}
802 % trigger a \newpage just before the given reference
803 % number - used to balance the columns on the last page
804 % adjust value as needed - may need to be readjusted if
805 % the document is modified later
806 %\IEEEtriggeratref{15}
808 \bibliographystyle{IEEEtran}
809 \bibliography{IEEEabrv,my_reference}
816 %%% ispell-local-dictionary: "american"
819 % LocalWords: Fanfakh Charr FIXME Tianhe DVFS HPC NAS NPB SMPI Rauber's Rauber
820 % LocalWords: CMOS EQ EPSA Franche Comté Tflop Rünger IUT Maréchal Juin cedex
821 % LocalWords: de badri muslim MPI TcpOld TcmOld dNew dOld cp Sopt Tcp Tcm Ps
822 % LocalWords: Scp Fmax Fdiff SimGrid GFlops Xeon EP BT