]> AND Private Git Repository - mpi-energy2.git/blob - Heter_paper.tex
Logo AND Algorithmique Numérique Distribuée

Private GIT Repository
b51db3b23149cd8cad677db096cd3599cd5c0cf8
[mpi-energy2.git] / Heter_paper.tex
1 \documentclass[conference]{IEEEtran}
2
3 \usepackage[T1]{fontenc}
4 \usepackage[utf8]{inputenc}
5 \usepackage[english]{babel}
6 \usepackage{algpseudocode}
7 \usepackage{graphicx}
8 \usepackage{algorithm}
9 \usepackage{subfig}
10 \usepackage{amsmath}
11 \usepackage{multirow}
12 \usepackage{url}
13 \DeclareUrlCommand\email{\urlstyle{same}}
14
15 \usepackage[autolanguage,np]{numprint}
16 \AtBeginDocument{%
17   \renewcommand*\npunitcommand[1]{\text{#1}}
18   \npthousandthpartsep{}}
19
20 \usepackage{xspace}
21 \usepackage[textsize=footnotesize]{todonotes}
22 \newcommand{\AG}[2][inline]{%
23   \todo[color=green!50,#1]{\sffamily\textbf{AG:} #2}\xspace}
24 \newcommand{\JC}[2][inline]{%
25   \todo[color=red!10,#1]{\sffamily\textbf{JC:} #2}\xspace}
26
27 \newcommand{\Xsub}[2]{\ensuremath{#1_\textit{#2}}}
28
29 \newcommand{\Dist}{\textit{Dist}}
30 \newcommand{\Eind}{\Xsub{E}{ind}}
31 \newcommand{\Enorm}{\Xsub{E}{Norm}}
32 \newcommand{\Eoriginal}{\Xsub{E}{Original}}
33 \newcommand{\Ereduced}{\Xsub{E}{Reduced}}
34 \newcommand{\Fdiff}{\Xsub{F}{diff}}
35 \newcommand{\Fmax}{\Xsub{F}{max}}
36 \newcommand{\Fnew}{\Xsub{F}{new}}
37 \newcommand{\Ileak}{\Xsub{I}{leak}}
38 \newcommand{\Kdesign}{\Xsub{K}{design}}
39 \newcommand{\MaxDist}{\textit{Max Dist}}
40 \newcommand{\Ntrans}{\Xsub{N}{trans}}
41 \newcommand{\Pdyn}{\Xsub{P}{dyn}}
42 \newcommand{\PnormInv}{\Xsub{P}{NormInv}}
43 \newcommand{\Pnorm}{\Xsub{P}{Norm}}
44 \newcommand{\Tnorm}{\Xsub{T}{Norm}}
45 \newcommand{\Pstates}{\Xsub{P}{states}}
46 \newcommand{\Pstatic}{\Xsub{P}{static}}
47 \newcommand{\Sopt}{\Xsub{S}{opt}}
48 \newcommand{\Tcomp}{\Xsub{T}{comp}}
49 \newcommand{\TmaxCommOld}{\Xsub{T}{Max Comm Old}}
50 \newcommand{\TmaxCompOld}{\Xsub{T}{Max Comp Old}}
51 \newcommand{\Tmax}{\Xsub{T}{max}}
52 \newcommand{\Tnew}{\Xsub{T}{New}}
53 \newcommand{\Told}{\Xsub{T}{Old}} 
54 \begin{document} 
55
56 \title{Energy Consumption Reduction for Message Passing Iterative  Applications in Heterogeneous Architecture Using DVFS}
57  
58 \author{% 
59   \IEEEauthorblockN{%
60     Jean-Claude Charr,
61     Raphaël Couturier,
62     Ahmed Fanfakh and
63     Arnaud Giersch
64   } 
65   \IEEEauthorblockA{%
66     FEMTO-ST Institute\\
67     University of Franche-Comté\\
68     IUT de Belfort-Montbéliard,
69     19 avenue du Maréchal Juin, BP 527, 90016 Belfort cedex, France\\
70     % Telephone: \mbox{+33 3 84 58 77 86}, % Raphaël
71     % Fax: \mbox{+33 3 84 58 77 81}\\      % Dept Info
72     Email: \email{{jean-claude.charr,raphael.couturier,ahmed.fanfakh_badri_muslim,arnaud.giersch}@univ-fcomte.fr}
73    }
74   }
75
76 \maketitle
77
78 \begin{abstract}
79 Computing platforms are consuming more and more energy due to the increase of the number of nodes composing them. 
80 To minimize the operating costs of these platforms many techniques have been used. Dynamic voltage and frequency 
81 scaling (DVFS) is one of them, it reduces the frequency of a CPU to lower its energy consumption. However, 
82 lowering the frequency of a CPU might increase the execution time of an application running on that processor. 
83 Therefore, the frequency that gives the best  tradeoff between the energy consumption and the performance of an 
84 application must be selected. 
85
86 In this paper, a new online frequencies selecting algorithm for heterogeneous platforms is presented. 
87 It selects the frequency that try to give the best tradeoff between energy saving and performance degradation, 
88 for each node computing the message passing iterative application. The algorithm has a small overhead and 
89 works without training or profiling. It uses a new energy model for message passing iterative applications 
90 running on a heterogeneous platform. The proposed algorithm is evaluated  on the Simgrid simulator while 
91 running the NAS parallel benchmarks. The experiments demonstrated that it reduces the energy consumption 
92 up to 35\% while limiting the performance degradation as much as possible. Finally, the algorithm is compared to an existing method and the comparison results show that it outperforms the latter.
93
94 \end{abstract}
95
96 \section{Introduction}
97 \label{sec.intro}
98 The need for more computing power is continually increasing. To partially satisfy this need, most supercomputers 
99 constructors just put more computing nodes in their platform. The resulting platform might achieve higher floating 
100 point operations per second (FLOPS), but the energy consumption and the heat dissipation are also increased. 
101 As an example, the Chinese supercomputer Tianhe-2 had the highest FLOPS in November 2014 according to the Top500 
102 list \cite{TOP500_Supercomputers_Sites}.  However, it was also the  most power hungry platform with its over 3 millions 
103 cores consuming around 17.8 megawatts. Moreover, according to the U.S. annual energy outlook 2014 
104 \cite{U.S_Annual.Energy.Outlook.2014}, the price of energy for 1 megawatt-hour 
105 was approximately equal to \$70. 
106 Therefore, the price of the energy consumed by the 
107 Tianhe-2 platform is approximately more than \$10 millions each year. 
108 The computing platforms must be more energy efficient and offer the highest number of FLOPS per watt possible, 
109 such as the L-CSC from the GSI Helmholtz Center which  
110 became the top of the Green500 list in November 2014 \cite{Green500_List}. 
111 This heterogeneous platform executes more than 5  GFLOPS per watt while consumed 57.15 kilowatts.
112
113 Besides hardware improvements, there are many software techniques to lower the energy consumption of these platforms, 
114 such as scheduling, DVFS, ... DVFS is a widely  used process to reduce the energy consumption of a processor by lowering 
115 its frequency \cite{Rizvandi_Some.Observations.on.Optimal.Frequency}. However, it also  reduces the number of FLOPS 
116 executed by the processor which might increase  the execution time of the application running over that processor.
117 Therefore, researchers used different optimization strategies to select the frequency that gives the best tradeoff  
118 between the energy reduction and 
119 performance degradation ratio. In \cite{Our_first_paper},  a frequency selecting algorithm 
120 was proposed to reduce the energy consumption of message passing iterative applications running over homogeneous platforms. The  results of the experiments showed significant energy consumption reductions. In this paper,  a new frequency selecting algorithm  adapted for heterogeneous platform  is presented. It selects the vector of frequencies, for a heterogeneous platform running a message passing iterative application,  that simultaneously tries to give the maximum energy reduction and minimum performance degradation ratio. The algorithm has a very small 
121 overhead, works online and does not need any training or profiling.  
122
123 This paper is organized as follows: Section~\ref{sec.relwork} presents some
124 related works from other authors.  Section~\ref{sec.exe} describes how the
125 execution time of message passing programs can be predicted.  It also presents an energy
126 model that predicts the energy consumption of an application running over a heterogeneous platform. Section~\ref{sec.compet} presents
127 the energy-performance objective function that maximizes the reduction of energy
128 consumption while minimizing the degradation of the program's performance.
129 Section~\ref{sec.optim} details the proposed frequency selecting algorithm then the precision of the proposed algorithm is verified. 
130 Section~\ref{sec.expe} presents the results of applying the algorithm on  the NAS parallel benchmarks and executing them 
131 on a heterogeneous platform. It shows the results of running three 
132 different power scenarios and comparing them. Moreover, it also shows the comparison results
133 between the proposed method and an existing method.
134 Finally, in Section~\ref{sec.concl} the paper is ended with a summary and some future works.
135
136 \section{Related works}
137 \label{sec.relwork}
138 DVFS is a technique enabled 
139 in modern processors to scale down both the voltage and the frequency of 
140 the CPU while computing, in order to reduce the energy consumption of the processor. DVFS is 
141 also  allowed in the GPUs to achieve the same goal. Reducing the frequency of a processor lowers its number of FLOPS and might degrade the performance of the application running on that processor, especially if it is compute bound. Therefore selecting the appropriate frequency for a processor to satisfy some objectives and while taking into account all the constraints, is not a trivial operation.  Many researchers used different strategies to tackle this problem. Some of them developed online methods that compute the new frequency while executing the application, such as ~\cite{Hao_Learning.based.DVFS,Spiliopoulos_Green.governors.Adaptive.DVFS}. Others used offline methods that might need to run the application and profile it before selecting the new frequency, such as ~\cite{Rountree_Bounding.energy.consumption.in.MPI,Cochran_Pack_and_Cap_Adaptive_DVFS}. The methods could be heuristics, exact  or brute force methods that satisfy varied objectives such as energy reduction or performance. They also could be adapted to the execution's environment and the type of the application such as sequential, parallel or distributed architecture, homogeneous or heterogeneous platform,  synchronous or asynchronous application, ... 
142
143 In this paper, we are interested in reducing energy for message passing iterative synchronous applications running over heterogeneous platforms.
144 Some works have already been done for such platforms and they can be classified into two types of heterogeneous platforms: 
145 \begin{itemize}
146
147 \item the platform is composed of homogeneous GPUs and homogeneous CPUs.
148 \item the platform is only composed of heterogeneous CPUs.
149
150 \end{itemize}
151
152 For the first type of platform, the compute intensive parallel tasks are executed on the  GPUs and the rest are executed 
153 on the CPUs.  Luley et al.
154 ~\cite{Luley_Energy.efficiency.evaluation.and.benchmarking}, proposed  a heterogeneous 
155 cluster composed of Intel Xeon CPUs and NVIDIA GPUs. Their main goal was to maximize the 
156 energy efficiency of the platform during computation by maximizing the number of FLOPS per watt generated. 
157 In~\cite{KaiMa_Holistic.Approach.to.Energy.Efficiency.in.GPU-CPU}, Kai Ma et al. developed a scheduling 
158 algorithm that distributes  workloads proportional to the computing power of the nodes which could be a GPU or a CPU. All the tasks must be completed at the same time.
159 In~\cite{Rong_Effects.of.DVFS.on.K20.GPU}, Rong et al. showed that 
160 a heterogeneous (GPUs and CPUs) cluster that enables DVFS gave better energy and performance 
161 efficiency than other clusters only composed of  CPUs.
162  
163 The work presented in this paper concerns the second type of platform, with heterogeneous CPUs.
164 Many methods were conceived to reduce the energy consumption of this type of platform.  Naveen et al.~\cite{Naveen_Power.Efficient.Resource.Scaling}  
165 developed a method that minimizes the value of $energy*delay^2$ (the delay is the sum of slack times that happen during synchronous communications) by dynamically assigning new frequencies to the CPUs of the heterogeneous cluster. Lizhe et al.~\cite{Lizhe_Energy.aware.parallel.task.scheduling} proposed
166 an algorithm that divides the executed tasks into two types: the critical and 
167 non critical tasks. The algorithm scales down the frequency of  non critical tasks proportionally to their  slack and communication times while limiting  the performance degradation percentage to less than 10\%. In~\cite{Joshi_Blackbox.prediction.of.impact.of.DVFS}, they developed 
168   a heterogeneous cluster composed of two  types 
169 of Intel and AMD processors. They use a gradient method to predict the impact of DVFS operations on performance.
170 In~\cite{Shelepov_Scheduling.on.Heterogeneous.Multicore} and \cite{Li_Minimizing.Energy.Consumption.for.Frame.Based.Tasks}, 
171  the best frequencies for a specified heterogeneous cluster are selected offline using some 
172 heuristic. Chen et al.~\cite{Chen_DVFS.under.quality.of.service.requirements} used a greedy dynamic programming approach to  
173 minimize the power consumption of heterogeneous severs  while respecting given time constraints. This approach 
174 had considerable overhead.
175 In contrast to the above described papers, this paper presents the following contributions :
176 \begin{enumerate}
177 \item  two new energy and performance models for message passing iterative synchronous applications running over 
178        a heterogeneous platform. Both models takes into account the communication and slack times. The models can predict the required energy and the execution time of the application.
179        
180 \item a new online frequency selecting algorithm for heterogeneous platforms. The algorithm has a very small 
181       overhead and does not need for any training or profiling. It uses a new optimization function which simultaneously maximizes the performance and minimizes the energy consumption of a message passing iterative synchronous application.
182       
183 \end{enumerate}
184
185 \section{The performance and energy consumption measurements on heterogeneous architecture}
186 \label{sec.exe}
187
188
189
190 \subsection{The execution time of message passing distributed 
191                 iterative applications on a heterogeneous platform}
192
193 In this paper, we are interested in reducing the energy consumption of message
194 passing distributed iterative synchronous applications running over
195 heterogeneous platforms. A heterogeneous platform is defined as a collection of
196 heterogeneous computing nodes interconnected via a high speed homogeneous
197 network. Therefore, each node has different characteristics such as computing
198 power (FLOPS), energy consumption, CPU's frequency range, \dots{} but they all
199 have the same network bandwidth and latency.
200
201 The overall execution time  of a distributed iterative synchronous application 
202 over a heterogeneous platform  consists of the sum of the computation time and 
203 the communication time for every iteration on a node. However, due to the 
204 heterogeneous computation power of the computing nodes, slack times might occur 
205 when fast nodes have to  wait, during synchronous communications, for  the slower 
206 nodes to finish  their computations (see Figure~(\ref{fig:heter})). 
207 Therefore,  the overall execution time  of the program is the execution time of the slowest
208 task which have the highest computation time and no slack time.
209   
210  \begin{figure}[t]
211   \centering
212    \includegraphics[scale=0.5]{fig/commtasks}
213   \caption{Parallel tasks on a heterogeneous platform}
214   \label{fig:heter}
215 \end{figure}
216
217 Dynamic Voltage and Frequency Scaling (DVFS) is a process, implemented in 
218 modern processors, that reduces the energy consumption of a CPU by scaling 
219 down its voltage and frequency.  Since DVFS lowers the frequency of a CPU 
220 and consequently its computing power, the execution time of a program running 
221 over that scaled down processor might increase, especially if the program is 
222 compute bound.  The frequency reduction process can be  expressed by the scaling 
223 factor S which is the ratio between  the maximum and the new frequency of a CPU 
224 as in (\ref{eq:s}).
225 \begin{equation}
226   \label{eq:s}
227  S = \frac{F_\textit{max}}{F_\textit{new}}
228 \end{equation}
229  The execution time of a compute bound sequential program is linearly proportional 
230  to the frequency scaling factor $S$.  On the other hand,  message passing 
231  distributed applications consist of two parts: computation and communication. 
232  The execution time of the computation part is linearly proportional to the 
233  frequency scaling factor $S$ but  the communication time is not affected by the 
234  scaling factor because  the processors involved remain idle during the  
235  communications~\cite{Freeh_Exploring.the.Energy.Time.Tradeoff}. 
236  The communication time for a task is the summation of  periods of 
237  time that begin with an MPI call for sending or receiving   a message 
238  until the message is synchronously sent or received.
239
240 Since in a heterogeneous platform, each node has different characteristics,
241 especially different frequency gears, when applying DVFS operations on these
242 nodes, they may get different scaling factors represented by a scaling vector:
243 $(S_1, S_2,\dots, S_N)$ where $S_i$ is the scaling factor of processor $i$. To
244 be able to predict the execution time of message passing synchronous iterative
245 applications running over a heterogeneous platform, for different vectors of
246 scaling factors, the communication time and the computation time for all the
247 tasks must be measured during the first iteration before applying any DVFS
248 operation. Then the execution time for one iteration of the application with any
249 vector of scaling factors can be predicted using (\ref{eq:perf}).
250 \begin{equation}
251   \label{eq:perf}
252  \textit  T_\textit{new} = 
253  \max_{i=1,2,\dots,N} ({TcpOld_{i}} \cdot S_{i}) +  MinTcm 
254 \end{equation}
255 Where:\\
256 \begin{equation}
257 \label{eq:perf}
258  MinTcm = \min_{i=1,2,\dots,N} (Tcm_i)
259 \end{equation}
260 where $TcpOld_i$ is the computation time  of processor $i$ during the first 
261 iteration and $MinTcm$ is the communication time of the slowest processor from 
262 the first iteration.  The model computes the maximum computation time 
263 with scaling factor from each node  added to the communication time of the 
264 slowest node, it means  only the  communication time without any slack time. 
265 Therefore, the execution time of the iterative application is 
266 equal to the execution time of one iteration as in (\ref{eq:perf}) multiplied 
267 by the number of iterations of that application.
268
269 This prediction model is developed from the model for predicting the execution time of 
270 message passing distributed applications for homogeneous architectures~\cite{Our_first_paper}. 
271 The execution time prediction model is used in the method for optimizing both 
272 energy consumption and performance of iterative methods, which is presented in the 
273 following sections.
274
275
276 \subsection{Energy model for heterogeneous platform}
277 Many researchers~\cite{Malkowski_energy.efficient.high.performance.computing,
278 Rauber_Analytical.Modeling.for.Energy,Zhuo_Energy.efficient.Dynamic.Task.Scheduling,
279 Rizvandi_Some.Observations.on.Optimal.Frequency} divide the power consumed by a processor into
280 two power metrics: the static and the dynamic power.  While the first one is
281 consumed as long as the computing unit is turned on, the latter is only consumed during
282 computation times.  The dynamic power $Pd$ is related to the switching
283 activity $\alpha$, load capacitance $C_L$, the supply voltage $V$ and
284 operational frequency $F$, as shown in (\ref{eq:pd}).
285 \begin{equation}
286   \label{eq:pd}
287   Pd = \alpha \cdot C_L \cdot V^2 \cdot F
288 \end{equation}
289 The static power $Ps$ captures the leakage power as follows:
290 \begin{equation}
291   \label{eq:ps}
292    Ps  = V \cdot N_{trans} \cdot K_{design} \cdot I_{leak}
293 \end{equation}
294 where V is the supply voltage, $N_{trans}$ is the number of transistors,
295 $K_{design}$ is a design dependent parameter and $I_{leak}$ is a
296 technology-dependent parameter.  The energy consumed by an individual processor
297 to execute a given program can be computed as:
298 \begin{equation}
299   \label{eq:eind}
300    E_\textit{ind} =  Pd \cdot Tcp + Ps \cdot T
301 \end{equation}
302 where $T$ is the execution time of the program, $Tcp$ is the computation
303 time and $Tcp \le T$.  $Tcp$ may be equal to $T$ if there is no
304 communication and no slack time.
305
306 The main objective of DVFS operation is to reduce the overall energy consumption~\cite{Le_DVFS.Laws.of.Diminishing.Returns}.  
307 The operational frequency $F$ depends linearly on the supply voltage $V$, i.e., $V = \beta \cdot F$ with some
308 constant $\beta$.~This equation is used to study the change of the dynamic
309 voltage with respect to various frequency values in~\cite{Rauber_Analytical.Modeling.for.Energy}.  The reduction
310 process of the frequency can be expressed by the scaling factor $S$ which is the
311 ratio between the maximum and the new frequency as in (\ref{eq:s}).
312 The CPU governors are power schemes supplied by the operating
313 system's kernel to lower a core's frequency. The new frequency 
314 $F_{new}$ from (\ref{eq:s}) can be calculated as follows:
315 \begin{equation}
316   \label{eq:fnew}
317    F_\textit{new} = S^{-1} \cdot F_\textit{max}
318 \end{equation}
319 Replacing $F_{new}$ in (\ref{eq:pd}) as in (\ref{eq:fnew}) gives the following 
320 equation for dynamic power consumption:
321 \begin{multline}
322   \label{eq:pdnew}
323    {P}_\textit{dNew} = \alpha \cdot C_L \cdot V^2 \cdot F_{new} = \alpha \cdot C_L \cdot \beta^2 \cdot F_{new}^3 \\
324    {} = \alpha \cdot C_L \cdot V^2 \cdot F_{max} \cdot S^{-3} = P_{dOld} \cdot S^{-3}
325 \end{multline}
326 where $ {P}_\textit{dNew}$  and $P_{dOld}$ are the  dynamic power consumed with the 
327 new frequency and the maximum frequency respectively.
328
329 According to (\ref{eq:pdnew}) the dynamic power is reduced by a factor of $S^{-3}$ when 
330 reducing the frequency by a factor of $S$~\cite{Rauber_Analytical.Modeling.for.Energy}. Since the FLOPS of a CPU is proportional 
331 to the frequency of a CPU, the computation time is increased proportionally to $S$.  
332 The new dynamic energy is the  dynamic power multiplied by the new time of computation 
333 and is given by the following equation:
334 \begin{equation}
335   \label{eq:Edyn}
336    E_\textit{dNew} = P_{dOld} \cdot S^{-3} \cdot (Tcp \cdot S)= S^{-2}\cdot P_{dOld} \cdot  Tcp 
337 \end{equation}
338 The static power is related to the power leakage of the CPU and is consumed during computation 
339 and even when idle. As in~\cite{Rauber_Analytical.Modeling.for.Energy,Zhuo_Energy.efficient.Dynamic.Task.Scheduling}, 
340  the static power of a processor is considered as constant 
341 during idle and computation periods, and for all its available frequencies. 
342 The static energy is the static power multiplied by the execution time of the program. 
343 According to the execution time model in (\ref{eq:perf}), the execution time of the program 
344 is the summation of the computation and the communication times. The computation time is linearly related  
345 to the frequency scaling factor, while this scaling factor does not affect the communication time. 
346 The static energy of a processor after scaling its frequency is computed as follows: 
347 \begin{equation}
348   \label{eq:Estatic}
349  E_\textit{s} = Ps \cdot (Tcp \cdot S  + Tcm)
350 \end{equation}
351
352 In the considered heterogeneous platform, each processor $i$ might have different dynamic and 
353 static powers, noted as $Pd_{i}$ and $Ps_{i}$ respectively. Therefore, even if the distributed 
354 message passing iterative application is load balanced, the computation time of each CPU $i$ 
355 noted $Tcp_{i}$ might be different and different frequency  scaling factors might be computed 
356 in order to decrease the overall energy consumption of the application and reduce the slack times. 
357 The communication time of a processor $i$ is noted as $Tcm_{i}$ and could contain slack times 
358 if it is communicating with slower nodes, see figure(\ref{fig:heter}). Therefore, all nodes do 
359 not have equal communication times. While the dynamic energy is computed according to the frequency 
360 scaling factor and the dynamic power of each node as in (\ref{eq:Edyn}), the static energy is 
361 computed as the sum of the execution time of each processor multiplied by its static power. 
362 The overall energy consumption of a message passing  distributed application executed over a 
363 heterogeneous platform during one iteration is the summation of all dynamic and static energies 
364 for each  processor.  It is computed as follows:
365 \begin{multline}
366   \label{eq:energy}
367  E = \sum_{i=1}^{N} {(S_i^{-2} \cdot Pd_{i} \cdot  Tcp_i)} + {} \\
368  \sum_{i=1}^{N} (Ps_{i} \cdot (\max_{i=1,2,\dots,N} (Tcp_i \cdot S_{i}) +
369   {MinTcm))}
370  \end{multline}
371
372 Reducing the frequencies of the processors according to the vector of
373 scaling factors $(S_1, S_2,\dots, S_N)$ may degrade the performance of the
374 application and thus, increase the static energy because the execution time is
375 increased~\cite{Kim_Leakage.Current.Moore.Law}. The overall energy consumption for the iterative 
376 application can be measured by measuring  the energy consumption for one iteration as in (\ref{eq:energy}) 
377 multiplied by the number of iterations of that application.
378
379
380 \section{Optimization of both energy consumption and performance}
381 \label{sec.compet}
382
383 Using the lowest frequency for each processor does not necessarily gives the most energy 
384 efficient execution of an application. Indeed, even though the dynamic power is reduced 
385 while scaling down the frequency of a processor, its computation power is proportionally 
386 decreased and thus the execution time might be drastically increased during which dynamic 
387 and static powers are being consumed. Therefore,  it might cancel any gains achieved by 
388 scaling down the frequency of all nodes to the minimum  and the overall energy consumption 
389 of the application might not be the optimal one. It is not trivial to select the appropriate 
390 frequency scaling factor for each processor while considering the characteristics of each processor 
391 (computation power, range of frequencies, dynamic and static powers) and the task executed 
392 (computation/communication ratio) in order to reduce the overall energy consumption and not 
393 significantly increase the execution time. In our previous work~\cite{Our_first_paper}, we  proposed a method 
394 that selects the optimal frequency scaling factor for a homogeneous cluster executing a message 
395 passing iterative synchronous application while giving the best trade-off  between the energy 
396 consumption and the performance for such applications. In this work we are interested in 
397 heterogeneous clusters as described above. Due to the heterogeneity of the processors, not 
398 one but a  vector of scaling factors should be selected and it must  give the best trade-off 
399 between energy consumption and performance. 
400
401 The relation between the energy consumption and the execution time for an application is 
402 complex and nonlinear, Thus, unlike the relation between the execution time 
403 and the scaling factor, the relation of the energy with the frequency scaling
404 factors is nonlinear, for more details refer to~\cite{Freeh_Exploring.the.Energy.Time.Tradeoff}.  
405 Moreover, they are not measured using the same metric.  To solve this problem,  the
406 execution time is normalized by computing the ratio between the new execution time (after 
407 scaling down the frequencies of some processors) and the initial one (with maximum 
408 frequency for all nodes) as follows:
409 \begin{multline}
410   \label{eq:pnorm}
411   P_\textit{Norm} = \frac{T_\textit{New}}{T_\textit{Old}}\\
412        {} = \frac{ \max_{i=1,2,\dots,N} (Tcp_{i} \cdot S_{i}) +MinTcm}
413            {\max_{i=1,2,\dots,N}{(Tcp_i+Tcm_i)}}
414 \end{multline}
415
416
417 In the same way, the energy is normalized by computing the ratio between the consumed energy 
418 while scaling down the frequency and the consumed energy with maximum frequency for all nodes:
419 \begin{multline}
420   \label{eq:enorm}
421   E_\textit{Norm} = \frac{E_\textit{Reduced}}{E_\textit{Original}} \\
422   {} = \frac{ \sum_{i=1}^{N}{(S_i^{-2} \cdot Pd_i \cdot  Tcp_i)} +
423  \sum_{i=1}^{N} {(Ps_i \cdot T_{New})}}{\sum_{i=1}^{N}{( Pd_i \cdot  Tcp_i)} +
424  \sum_{i=1}^{N} {(Ps_i \cdot T_{Old})}}
425 \end{multline} 
426 Where $E_\textit{Reduced}$ and $E_\textit{Original}$ are computed using (\ref{eq:energy}) and
427   $T_{New}$ and $T_{Old}$ are computed as in (\ref{eq:pnorm}).
428
429 While the main 
430 goal is to optimize the energy and execution time at the same time, the normalized 
431 energy and execution time curves are not in the same direction. According 
432 to the equations~(\ref{eq:pnorm}) and (\ref{eq:enorm}), the vector  of frequency
433 scaling factors $S_1,S_2,\dots,S_N$ reduce both the energy and the execution
434 time simultaneously.  But the main objective is to produce maximum energy
435 reduction with minimum execution time reduction.  
436   
437 This problem can be solved by making the optimization process for energy and 
438 execution time follow the same direction.  Therefore, the equation of the 
439 normalized execution time is inverted which gives the normalized performance equation, as follows:
440 \begin{multline}
441   \label{eq:pnorm_inv}
442   P_\textit{Norm} = \frac{T_\textit{Old}}{T_\textit{New}}\\
443           = \frac{\max_{i=1,2,\dots,N}{(Tcp_i+Tcm_i)}}
444             { \max_{i=1,2,\dots,N} (Tcp_{i} \cdot S_{i}) + MinTcm} 
445 \end{multline}
446
447
448 \begin{figure}
449   \centering
450   \subfloat[Homogeneous platform]{%
451     \includegraphics[width=.30\textwidth]{fig/homo}\label{fig:r1}}%
452   
453   
454   \subfloat[Heterogeneous platform]{%
455     \includegraphics[width=.30\textwidth]{fig/heter}\label{fig:r2}}
456   \label{fig:rel}
457   \caption{The energy and performance relation}
458 \end{figure}
459
460 Then, the objective function can be modeled   as finding the maximum distance
461 between the energy curve (\ref{eq:enorm}) and the  performance
462 curve (\ref{eq:pnorm_inv}) over all available sets of scaling factors.  This
463 represents the minimum energy consumption with minimum execution time (maximum 
464 performance) at the same time, see figure~(\ref{fig:r1}) or figure~(\ref{fig:r2}). Then the objective
465 function has the following form:
466 \begin{equation}
467   \label{eq:max}
468   Max Dist = 
469   \max_{i=1,\dots F, j=1,\dots,N}
470       (\overbrace{P_\textit{Norm}(S_{ij})}^{\text{Maximize}} -
471        \overbrace{E_\textit{Norm}(S_{ij})}^{\text{Minimize}} )
472 \end{equation}
473 where $N$ is the number of nodes and $F$ is the  number of available frequencies for each node. 
474 Then, the optimal set of scaling factors that satisfies (\ref{eq:max}) can be selected.  
475 The objective function can work with any energy model or any power values for each node 
476 (static and dynamic powers). However, the most energy reduction gain can be achieved when 
477 the energy curve has a convex form as shown in~\cite{Zhuo_Energy.efficient.Dynamic.Task.Scheduling,Rauber_Analytical.Modeling.for.Energy,Hao_Learning.based.DVFS}.
478
479 \section{The scaling factors selection algorithm for heterogeneous platforms }
480 \label{sec.optim}
481
482 \subsection{The algorithm details}
483 In this section algorithm \ref{HSA} is presented. It selects the frequency scaling factors 
484 vector that gives the best trade-off between minimizing the energy consumption  and maximizing 
485 the performance of a message passing synchronous iterative application executed on a heterogeneous 
486 platform. It works online during the execution time of the iterative message passing program.  
487 It uses information gathered during the first iteration such as the computation time and the 
488 communication time in one iteration for each node. The algorithm is executed  after the first 
489 iteration and returns a vector of optimal frequency scaling factors   that satisfies the objective 
490 function (\ref{eq:max}). The program apply DVFS operations to change the frequencies of the CPUs 
491 according to the computed scaling factors.  This algorithm is called just once during the execution 
492 of the program. Algorithm~(\ref{dvfs}) shows where and when the proposed scaling algorithm is called 
493 in the iterative MPI program.
494
495 The nodes in a heterogeneous platform have different computing powers, thus while executing message 
496 passing iterative synchronous applications, fast nodes have to wait for the slower ones to finish their 
497 computations before being able to synchronously communicate with them as in figure (\ref{fig:heter}). 
498 These periods are called idle or slack times. 
499 The algorithm takes into account this problem and tries to reduce these slack times when selecting the 
500 frequency scaling factors vector. At first, it selects initial frequency scaling factors that increase 
501 the execution times of fast nodes and  minimize the  differences between  the  computation times of 
502 fast and slow nodes. The value of the initial frequency scaling factor  for each node is inversely 
503 proportional to its computation time that was gathered from the first iteration. These initial frequency 
504 scaling factors are computed as   a ratio between the computation time of the slowest node and the 
505 computation time of the node $i$ as follows:
506 \begin{equation}
507   \label{eq:Scp}
508  Scp_{i} = \frac{\max_{i=1,2,\dots,N}(Tcp_i)}{Tcp_i}
509 \end{equation}
510 Using the initial  frequency scaling factors computed in (\ref{eq:Scp}), the algorithm computes 
511 the initial frequencies for all nodes as a ratio between the maximum frequency of node $i$  
512 and the computation scaling factor $Scp_i$ as follows:
513 \begin{equation}
514   \label{eq:Fint}
515  F_{i} = \frac{Fmax_i}{Scp_i},~{i=1,2,\cdots,N}
516 \end{equation}
517 If the computed initial frequency for a node is not available in the gears of that node, the computed 
518 initial frequency is replaced by the nearest available frequency. In  figure (\ref{fig:st_freq}), 
519 the nodes are  sorted by their computing powers in ascending order and the frequencies of the faster 
520 nodes are scaled down according to the computed initial frequency scaling factors. The resulting new 
521 frequencies are colored in blue in  figure (\ref{fig:st_freq}). This set of frequencies can be considered 
522 as a higher bound for the search space of the optimal vector of frequencies because selecting frequency 
523 scaling factors higher than the higher bound will not improve the performance of the application and 
524 it will increase its overall energy consumption. Therefore the algorithm that selects the frequency 
525 scaling factors starts the search method from these initial frequencies and takes a downward search direction 
526 toward lower frequencies. The algorithm iterates on all left frequencies, from the higher bound until all 
527 nodes reach their minimum frequencies, to compute their overall energy consumption and performance, and select 
528 the optimal frequency scaling factors vector. At each iteration the algorithm determines the slowest node 
529 according to (\ref{eq:perf}) and keeps its frequency unchanged, while it lowers the frequency of  
530 all other nodes by one gear.
531 The new overall energy consumption and execution time are computed according to the new scaling factors. 
532 The optimal set of frequency scaling factors is the set that gives the highest distance according to  the objective 
533 function (\ref{eq:max}).
534
535 The plots~(\ref{fig:r1} and \ref{fig:r2}) illustrate the normalized performance and consumed energy for an 
536 application running on a homogeneous platform and a heterogeneous platform respectively while increasing the 
537 scaling factors. It can be noticed that in a homogeneous platform the search for the optimal scaling factor 
538 should be started from the maximum frequency because the performance and the consumed energy is decreased since  
539 the beginning of the plot. On the other hand, in  the heterogeneous platform the performance is  maintained at 
540 the beginning of the plot even if the frequencies of the faster nodes are decreased until the scaled down nodes 
541 have computing powers lower than the slowest node. In other words, until they reach the higher bound. It can 
542 also be noticed that the higher the difference between the faster nodes and the slower nodes is, the bigger 
543 the maximum distance between the energy curve and the performance curve is while varying the scaling factors 
544 which results in bigger energy savings. 
545 \begin{figure}[t]
546   \centering
547     \includegraphics[scale=0.5]{fig/start_freq}
548   \caption{Selecting the initial frequencies}
549   \label{fig:st_freq}
550 \end{figure}
551
552
553
554
555 \begin{algorithm}
556   \begin{algorithmic}[1]
557     % \footnotesize
558     \Require ~
559     \begin{description}
560     \item[$Tcp_i$] array of all computation times for all nodes during one iteration and with highest frequency.
561     \item[$Tcm_i$] array of all communication times for all nodes during one iteration and with highest frequency.
562     \item[$Fmax_i$] array of the maximum frequencies for all nodes.
563     \item[$Pd_i$] array of the dynamic powers for all nodes.
564     \item[$Ps_i$] array of the static powers for all nodes.
565     \item[$Fdiff_i$] array of the difference between two successive frequencies for all nodes.
566     \end{description}
567     \Ensure $Sopt_1,Sopt_2 \dots, Sopt_N$ is a vector of optimal scaling factors
568
569     \State $ Scp_i \gets \frac{\max_{i=1,2,\dots,N}(Tcp_i)}{Tcp_i} $
570     \State $F_{i} \gets  \frac{Fmax_i}{Scp_i},~{i=1,2,\cdots,N}$
571     \State Round the computed initial frequencies $F_i$ to the closest one available in each node.
572     \If{(not the first frequency)}
573           \State $F_i \gets F_i+Fdiff_i,~i=1,\dots,N.$
574     \EndIf 
575     \State $T_\textit{Old} \gets max_{~i=1,\dots,N } (Tcp_i+Tcm_i)$
576     \State $E_\textit{Original} \gets \sum_{i=1}^{N}{( Pd_i \cdot  Tcp_i)} +\sum_{i=1}^{N} {(Ps_i \cdot T_{Old})}$
577     \State  $Sopt_{i} \gets 1,~i=1,\dots,N. $
578     \State $Dist \gets 0 $
579     \While {(all nodes not reach their  minimum  frequency)}
580         \If{(not the last freq. \textbf{and} not the slowest node)}
581         \State $F_i \gets F_i - Fdiff_i,~i=1,\dots,N.$
582         \State $S_i \gets \frac{Fmax_i}{F_i},~i=1,\dots,N.$
583         \EndIf
584        \State $T_{New} \gets max_\textit{~i=1,\dots,N} (Tcp_{i} \cdot S_{i}) + MinTcm $
585        \State $E_\textit{Reduced} \gets \sum_{i=1}^{N}{(S_i^{-2} \cdot Pd_i \cdot  Tcp_i)} + $  \hspace*{43 mm} 
586                $\sum_{i=1}^{N} {(Ps_i \cdot T_{New})} $
587        \State $ P_\textit{Norm} \gets \frac{T_\textit{Old}}{T_\textit{New}}$
588        \State $E_\textit{Norm}\gets \frac{E_\textit{Reduced}}{E_\textit{Original}}$
589       \If{$(\Pnorm - \Enorm > \Dist)$}
590         \State $Sopt_{i} \gets S_{i},~i=1,\dots,N. $
591         \State $\Dist \gets \Pnorm - \Enorm$
592       \EndIf
593     \EndWhile
594     \State  Return $Sopt_1,Sopt_2,\dots,Sopt_N$
595   \end{algorithmic}
596   \caption{frequency scaling factors selection algorithm}
597   \label{HSA}
598 \end{algorithm}
599
600 \begin{algorithm}
601   \begin{algorithmic}[1]
602     % \footnotesize
603     \For {$k=1$ to \textit{some iterations}}
604       \State Computations section.
605       \State Communications section.
606       \If {$(k=1)$}
607         \State Gather all times of computation and\newline\hspace*{3em}%
608                communication from each node.
609         \State Call algorithm \ref{HSA}.
610         \State Compute the new frequencies from the\newline\hspace*{3em}%
611                returned optimal scaling factors.
612         \State Set the new frequencies to nodes.
613       \EndIf
614     \EndFor
615   \end{algorithmic}
616   \caption{DVFS algorithm}
617   \label{dvfs}
618 \end{algorithm}
619
620 \subsection{The evaluation of the proposed algorithm}
621 \label{sec.verif.algo}
622 The precision of the proposed algorithm mainly depends on the execution time prediction model defined in 
623 (\ref{eq:perf}) and the energy model computed by (\ref{eq:energy}). 
624 The energy model is also significantly dependent  on the execution time model because the static energy is 
625 linearly related the execution time and the dynamic energy is related to the computation time. So, all of 
626 the works presented in this paper is based on the execution time model. To verify this model, the predicted 
627 execution time was compared to  the real execution time over SimGrid/SMPI simulator, v3.10~\cite{casanova+giersch+legrand+al.2014.versatile}, 
628 for all  the NAS parallel benchmarks NPB v3.3 
629 \cite{NAS.Parallel.Benchmarks}, running class B on 8 or 9 nodes. The comparison showed that the proposed execution time model is very precise, 
630 the maximum normalized difference between the predicted execution time  and the real execution time is equal 
631 to 0.03 for all the NAS benchmarks.
632
633 Since  the proposed algorithm is not an exact method and does not test all the possible solutions (vectors of scaling factors) 
634 in the search space. To prove its efficiency, it was compared on small instances to a brute force search algorithm 
635 that tests all the possible solutions. The brute force algorithm was applied to different NAS benchmarks classes with 
636 different number of nodes. The solutions returned by the brute force algorithm and the proposed algorithm were identical 
637 and the proposed algorithm was on average 10 times faster than the brute force algorithm. It has a small execution time: 
638 for a heterogeneous cluster composed of four different types of nodes having the characteristics presented in 
639 table~\ref{table:platform}, it takes on average \np[ms]{0.04}  for 4 nodes and \np[ms]{0.15} on average for 144 nodes 
640 to compute the best scaling factors vector.  The algorithm complexity is $O(F\cdot (N \cdot4) )$, where $F$ is the number 
641 of iterations and $N$ is the number of computing nodes. The algorithm needs  from 12 to 20 iterations to select the best 
642 vector of frequency scaling factors that gives the results of the next sections.
643
644 \section{Experimental results}
645 \label{sec.expe}
646 To evaluate the efficiency and the overall energy consumption reduction of algorithm~ \ref{HSA}, 
647 it was applied to the NAS parallel benchmarks NPB v3.3. The experiments were executed 
648 on the simulator SimGrid/SMPI which offers easy tools to create a heterogeneous platform and run 
649 message passing applications over it. The  heterogeneous platform that was used in the experiments, 
650 had one core per node because just one  process was executed per node. 
651 The heterogeneous platform  was composed of four types of nodes. Each type of nodes had different 
652 characteristics such as the maximum CPU frequency, the number of
653 available frequencies and the computational power, see Table \ref{table:platform}. The characteristics 
654 of these different types of  nodes are inspired   from the specifications of real Intel processors. 
655 The heterogeneous platform had up to 144 nodes and had nodes from the four types in equal proportions, 
656 for example if  a benchmark was executed on 8 nodes, 2 nodes from each type were used. Since the constructors 
657 of CPUs do not specify the dynamic and the static power of their CPUs, for each type of node they were 
658 chosen proportionally to its computing power (FLOPS).  In the initial heterogeneous platform,  while computing 
659 with highest frequency, each node  consumed power proportional to its computing power which 80\% of it was 
660 dynamic power and the rest was 20\% for the static power, the same assumption  was made in \cite{Our_first_paper,Rauber_Analytical.Modeling.for.Energy}. 
661 Finally, These nodes were connected via an ethernet network with 1 Gbit/s bandwidth.
662
663
664 \begin{table}[htb]
665   \caption{Heterogeneous nodes characteristics}
666   % title of Table
667   \centering
668   \begin{tabular}{|*{7}{l|}}
669     \hline
670     Node          &Simulated  & Max      & Min          & Diff.          & Dynamic      & Static \\
671     type          &GFLOPS     & Freq.    & Freq.        & Freq.          & power        & power \\
672                   &           & GHz      & GHz          &GHz             &              &       \\
673     \hline
674     1             &40         & 2.5      & 1.2          & 0.1            & 20~w         &4~w    \\
675          
676     \hline
677     2             &50         & 2.66     & 1.6          & 0.133          & 25~w         &5~w    \\
678                   
679     \hline
680     3             &60         & 2.9      & 1.2          & 0.1            & 30~w         &6~w    \\
681                   
682     \hline
683     4             &70         & 3.4      & 1.6          & 0.133          & 35~w         &7~w    \\
684                   
685     \hline
686   \end{tabular}
687   \label{table:platform}
688 \end{table}
689
690  
691 %\subsection{Performance prediction verification}
692
693
694 \subsection{The experimental results of the scaling algorithm}
695 \label{sec.res}
696
697
698 The proposed algorithm was applied to the seven parallel NAS benchmarks (EP, CG, MG, FT, BT, LU and SP) 
699 and the benchmarks were executed with the three classes: A,B and C. However, due to the lack of space in 
700 this paper, only the results of the biggest class, C, are presented while being run on different number 
701 of nodes, ranging  from 4 to 128 or 144 nodes depending on the benchmark being executed. Indeed, the 
702 benchmarks CG, MG, LU, EP and FT should be executed on $1, 2, 4, 8, 16, 32, 64, 128$ nodes. 
703 The other benchmarks such as BT and SP should be executed on $1, 4, 9, 16, 36, 64, 144$ nodes.
704
705  
706  
707 \begin{table}[htb]
708   \caption{Running NAS benchmarks on 4 nodes }
709   % title of Table
710   \centering
711   \begin{tabular}{|*{7}{l|}}
712     \hline
713     Program     & Execution     & Energy         & Energy      & Performance        & Distance      \\
714     name       & time/s        & consumption/J  & saving\%    & degradation\%      &               \\
715     \hline
716     CG         &  64.64        & 3560.39        &34.16        &6.72               &27.44       \\
717     \hline 
718     MG         & 18.89         & 1074.87            &35.37            &4.34                   &31.03       \\
719    \hline
720     EP         &79.73          &5521.04         &26.83            &3.04               &23.79      \\
721    \hline
722     LU         &308.65         &21126.00           &34.00             &6.16                   &27.84      \\
723     \hline
724     BT         &360.12         &21505.55           &35.36         &8.49               &26.87     \\
725    \hline
726     SP         &234.24         &13572.16           &35.22         &5.70               &29.52    \\
727    \hline
728     FT         &81.58          &4151.48        &35.58         &0.99                   &34.59    \\
729 \hline 
730   \end{tabular}
731   \label{table:res_4n}
732 \end{table}
733
734 \begin{table}[htb]
735   \caption{Running NAS benchmarks on 8 and 9 nodes }
736   % title of Table
737   \centering
738   \begin{tabular}{|*{7}{l|}}
739     \hline
740     Program    & Execution     & Energy         & Energy      & Performance        & Distance      \\
741     name       & time/s        & consumption/J  & saving\%    & degradation\%      &               \\
742     \hline
743     CG         &36.11              &3263.49             &31.25        &7.12                    &24.13     \\
744     \hline 
745     MG         &8.99           &953.39          &33.78        &6.41                    &27.37     \\
746    \hline
747     EP         &40.39          &5652.81         &27.04        &0.49                    &26.55     \\
748    \hline
749     LU         &218.79             &36149.77        &28.23        &0.01                    &28.22      \\
750     \hline
751     BT         &166.89         &23207.42            &32.32            &7.89                    &24.43      \\
752    \hline
753     SP         &104.73         &18414.62            &24.73            &2.78                    &21.95      \\
754    \hline
755     FT         &51.10          &4913.26         &31.02        &2.54                    &28.48      \\
756 \hline 
757   \end{tabular}
758   \label{table:res_8n}
759 \end{table}
760
761 \begin{table}[htb]
762   \caption{Running NAS benchmarks on 16 nodes }
763   % title of Table
764   \centering
765   \begin{tabular}{|*{7}{l|}}
766     \hline
767     Program     & Execution     & Energy         & Energy      & Performance        & Distance      \\
768     name       & time/s        & consumption/J  & saving\%    & degradation\%      &               \\
769     \hline
770     CG         &31.74          &4373.90         &26.29        &9.57                    &16.72          \\
771     \hline 
772     MG         &5.71           &1076.19         &32.49        &6.05                    &26.44         \\
773    \hline
774     EP         &20.11          &5638.49         &26.85        &0.56                    &26.29         \\
775    \hline
776     LU         &144.13         &42529.06            &28.80            &6.56                    &22.24         \\
777     \hline
778     BT         &97.29          &22813.86            &34.95        &5.80                &29.15         \\
779    \hline
780     SP         &66.49          &20821.67            &22.49            &3.82                    &18.67         \\
781    \hline
782     FT             &37.01          &5505.60             &31.59        &6.48                    &25.11         \\
783 \hline 
784   \end{tabular}
785   \label{table:res_16n}
786 \end{table}
787
788 \begin{table}[htb]
789   \caption{Running NAS benchmarks on 32 and 36 nodes }
790   % title of Table
791   \centering
792   \begin{tabular}{|*{7}{l|}}
793     \hline
794     Program    & Execution     & Energy         & Energy      & Performance        & Distance      \\
795     name       & time/s        & consumption/J  & saving\%    & degradation\%      &               \\
796     \hline
797     CG         &32.35          &6704.21         &16.15        &5.30                    &10.85           \\
798     \hline 
799     MG         &4.30           &1355.58         &28.93        &8.85                    &20.08          \\
800    \hline
801     EP         &9.96           &5519.68         &26.98        &0.02                    &26.96          \\
802    \hline
803     LU         &99.93          &67463.43            &23.60            &2.45                    &21.15          \\
804     \hline
805     BT         &48.61          &23796.97            &34.62            &5.83                    &28.79          \\
806    \hline
807     SP         &46.01          &27007.43            &22.72            &3.45                    &19.27           \\
808    \hline
809     FT             &28.06          &7142.69             &23.09        &2.90                    &20.19           \\
810 \hline 
811   \end{tabular}
812   \label{table:res_32n}
813 \end{table}
814
815 \begin{table}[htb]
816   \caption{Running NAS benchmarks on 64 nodes }
817   % title of Table
818   \centering
819   \begin{tabular}{|*{7}{l|}}
820     \hline
821     Program    & Execution     & Energy         & Energy      & Performance        & Distance      \\
822     name       & time/s        & consumption/J  & saving\%    & degradation\%      &               \\
823     \hline
824     CG         &46.65          &17521.83            &8.13             &1.68                    &6.45           \\
825     \hline 
826     MG         &3.27           &1534.70         &29.27        &14.35               &14.92          \\
827    \hline
828     EP         &5.05           &5471.1084           &27.12            &3.11                &24.01         \\
829    \hline
830     LU         &73.92          &101339.16           &21.96            &3.67                    &18.29         \\
831     \hline
832     BT         &39.99          &27166.71            &32.02            &12.28               &19.74         \\
833    \hline
834     SP         &52.00          &49099.28            &24.84            &0.03                    &24.81         \\
835    \hline
836     FT         &25.97          &10416.82        &20.15        &4.87                    &15.28         \\
837 \hline 
838   \end{tabular}
839   \label{table:res_64n}
840 \end{table}
841
842
843 \begin{table}[htb]
844   \caption{Running NAS benchmarks on 128 and 144 nodes }
845   % title of Table
846   \centering
847   \begin{tabular}{|*{7}{l|}}
848     \hline
849     Program    & Execution     & Energy         & Energy      & Performance        & Distance     \\
850     name       & time/s        & consumption/J  & saving\%    & degradation\%      &              \\
851     \hline
852     CG         &56.92          &41163.36        &4.00         &1.10                    &2.90          \\
853     \hline 
854     MG         &3.55           &2843.33         &18.77        &10.38               &8.39          \\
855    \hline
856     EP         &2.67           &5669.66         &27.09        &0.03                    &27.06         \\
857    \hline
858     LU         &51.23          &144471.90       &16.67        &2.36                    &14.31         \\
859     \hline
860     BT         &37.96          &44243.82            &23.18            &1.28                    &21.90         \\
861    \hline
862     SP         &64.53          &115409.71           &26.72            &0.05                    &26.67         \\
863    \hline
864     FT         &25.51          &18808.72            &12.85            &2.84                    &10.01         \\
865 \hline 
866   \end{tabular}
867   \label{table:res_128n}
868 \end{table}
869 The overall energy consumption was computed for each instance according to the energy 
870 consumption  model (\ref{eq:energy}), with and without applying the algorithm. The 
871 execution time was also measured for all these experiments. Then, the energy saving 
872 and performance degradation percentages were computed for each instance.  
873 The results are presented in Tables (\ref{table:res_4n}, \ref{table:res_8n}, \ref{table:res_16n}, 
874 \ref{table:res_32n}, \ref{table:res_64n} and \ref{table:res_128n}). All these results are the 
875 average values from many experiments for  energy savings and performance degradation.
876 The tables  show the experimental results for running the NAS parallel benchmarks on different 
877 number of nodes. The experiments show that the algorithm reduce significantly the energy 
878 consumption (up to 35\%) and tries to limit the performance degradation. They also show that 
879 the  energy saving percentage is decreased  when the number of the computing nodes is increased. 
880 This reduction is due to the increase of the communication times compared to the execution times 
881 when the benchmarks are run over a high number of nodes. Indeed, the benchmarks with the same class, C, 
882 are executed on different number of nodes, so the computation required for each iteration is divided 
883 by the number of computing nodes.   On the other hand, more communications are required when increasing 
884 the number of nodes so the static energy is increased linearly according to the communication time and 
885 the dynamic power is less relevant in the overall energy consumption. Therefore, reducing the frequency 
886 with algorithm~(\ref{HSA}) have less effect in reducing the overall energy savings. It can also be 
887 noticed that for the benchmarks EP and SP that contain little or no communications,  the energy savings 
888 are not significantly affected with the high number of nodes. No experiments were conducted using bigger 
889 classes such as D, because they require a lot of memory(more than 64GB) when being executed by the simulator 
890 on one machine. The maximum distance between the normalized energy curve and the normalized performance 
891 for each instance is also shown in the result tables. It is decreased in the same way as the energy 
892 saving percentage. The tables also show that the performance degradation percentage is not significantly 
893 increased when the number of computing nodes is increased because the computation times are small when 
894 compared to the communication times.  
895
896
897  
898 \begin{figure}
899   \centering
900   \subfloat[Energy saving]{%
901     \includegraphics[width=.30\textwidth]{fig/energy}\label{fig:energy}}%
902   
903   \subfloat[Performance degradation ]{%
904     \includegraphics[width=.30\textwidth]{fig/per_deg}\label{fig:per_deg}}
905   \label{fig:avg}
906   \caption{The energy and performance for all NAS benchmarks running with difference number of nodes}
907 \end{figure}
908
909 Plots (\ref{fig:energy} and \ref{fig:per_deg}) present the energy saving and performance degradation 
910 respectively for all the benchmarks according to the number of used nodes. As shown in the first plot, 
911 the energy saving percentages of the benchmarks MG, LU, BT and FT are decreased linearly  when the  
912 number of nodes is increased. While for the  EP and SP benchmarks, the energy saving percentage is not 
913 affected by the increase of the number of computing nodes, because in these benchmarks there are little or 
914 no communications. Finally, the energy saving of the GC benchmark  is significantly decreased when the number 
915 of nodes is increased because  this benchmark has more communications than the others. The second plot 
916 shows that the performance degradation percentages of most of the benchmarks are decreased when they 
917 run on a big number of nodes because they spend more time communicating than computing, thus, scaling 
918 down the frequencies of some nodes have less effect on the performance. 
919
920
921
922
923 \subsection{The results for different power consumption scenarios}
924 \label{sec.compare}
925 The results of the previous section were obtained while using processors that consume during computation 
926 an overall power which is 80\% composed of  dynamic power and 20\% of static power. In this section, 
927 these ratios are changed and two new power scenarios are considered in order to evaluate how the proposed  
928 algorithm adapts itself according to the static and dynamic power values.  The two new power scenarios 
929 are the following: 
930
931 \begin{itemize}
932 \item 70\% dynamic power  and 30\% static power
933 \item 90\% dynamic power  and 10\% static power
934 \end{itemize}
935
936 The NAS parallel benchmarks were executed again over processors that follow the new power scenarios. 
937 The class C of each benchmark was run over 8 or 9 nodes and the results are presented in  Tables 
938 \ref{table:res_s1} and \ref{table:res_s2}. These tables show that the energy saving percentage of the 70\%-30\% 
939 scenario is less for all benchmarks compared to the energy saving of the 90\%-10\% scenario. Indeed, in the latter 
940 more dynamic power is consumed when nodes are running on their maximum frequencies, thus, scaling down the frequency 
941 of the nodes results in higher energy savings than in the 70\%-30\% scenario. On the other hand,  the performance 
942 degradation percentage is less in the 70\%-30\% scenario  compared to the 90\%-10\%  scenario. This is due to the 
943 higher static power percentage in the first scenario which makes it more relevant in the overall consumed energy. 
944 Indeed, the static energy is related to the execution time and if the performance is  degraded the total consumed 
945 static energy is directly increased. Therefore, the proposed algorithm do not scales down much the frequencies of the 
946 nodes  in order to limit the increase of the execution time and thus limiting the effect of the consumed static energy.
947
948 The two new power scenarios are compared to the old one in figure (\ref{fig:sen_comp}). It shows the average of 
949 the performance degradation, the energy saving and the distances for all NAS benchmarks of class C running on 8 or 9 nodes. 
950 The comparison shows that  the energy saving ratio is proportional to the dynamic power ratio: it is increased 
951 when applying the  90\%-10\% scenario because at maximum frequency the dynamic  energy is the  most relevant 
952 in the overall consumed energy and can be reduced by lowering the frequency of some processors. On the other hand, 
953 the energy saving is decreased when  the 70\%-30\% scenario is used because the dynamic  energy is less relevant in 
954 the overall consumed energy and lowering the frequency do not returns big energy savings.
955 Moreover, the average of the performance degradation is decreased when using a higher ratio for static power 
956 (e.g. 70\%-30\% scenario and 80\%-20\% scenario). Since the proposed algorithm optimizes the energy consumption 
957 when using a higher ratio for dynamic power the algorithm selects bigger frequency scaling factors that result in 
958 more energy saving but less performance, for example see the figure (\ref{fig:scales_comp}). The opposite happens 
959 when using a higher ratio for  static  power, the algorithm proportionally  selects  smaller scaling values which 
960 results in less energy saving but less performance degradation. 
961
962
963  \begin{table}[htb]
964   \caption{The results of 70\%-30\% powers scenario}
965   % title of Table
966   \centering
967   \begin{tabular}{|*{6}{l|}}
968     \hline
969     Program    & Energy          & Energy      & Performance        & Distance     \\
970     name       & consumption/J   & saving\%    & degradation\%      &              \\
971     \hline
972     CG         &4144.21          &22.42        &7.72                &14.70         \\
973     \hline 
974     MG         &1133.23          &24.50        &5.34                &19.16          \\
975    \hline
976     EP         &6170.30         &16.19         &0.02                &16.17          \\
977    \hline
978     LU         &39477.28        &20.43         &0.07                &20.36          \\
979     \hline
980     BT         &26169.55            &25.34             &6.62                &18.71          \\
981    \hline
982     SP         &19620.09            &19.32             &3.66                &15.66          \\
983    \hline
984     FT         &6094.07         &23.17         &0.36                &22.81          \\
985 \hline 
986   \end{tabular}
987   \label{table:res_s1}
988 \end{table}
989
990
991
992 \begin{table}[htb]
993   \caption{The results of 90\%-10\% powers scenario}
994   % title of Table
995   \centering
996   \begin{tabular}{|*{6}{l|}}
997     \hline
998     Program    & Energy          & Energy      & Performance        & Distance     \\
999     name       & consumption/J   & saving\%    & degradation\%      &              \\
1000     \hline
1001     CG         &2812.38          &36.36        &6.80                &29.56         \\
1002     \hline 
1003     MG         &825.427          &38.35        &6.41                &31.94         \\
1004    \hline
1005     EP         &5281.62          &35.02        &2.68                &32.34         \\
1006    \hline
1007     LU         &31611.28             &39.15        &3.51                    &35.64        \\
1008     \hline
1009     BT         &21296.46             &36.70            &6.60                &30.10       \\
1010    \hline
1011     SP         &15183.42             &35.19            &11.76               &23.43        \\
1012    \hline
1013     FT         &3856.54          &40.80        &5.67                &35.13        \\
1014 \hline 
1015   \end{tabular}
1016   \label{table:res_s2}
1017 \end{table}
1018
1019
1020 \begin{figure}
1021   \centering
1022   \subfloat[Comparison  of the results on 8 nodes]{%
1023     \includegraphics[width=.30\textwidth]{fig/sen_comp}\label{fig:sen_comp}}%
1024
1025   \subfloat[Comparison the selected frequency scaling factors of MG benchmark class C running on 8 nodes]{%
1026     \includegraphics[width=.30\textwidth]{fig/three_scenarios}\label{fig:scales_comp}}
1027   \label{fig:comp}
1028   \caption{The comparison of the three power scenarios}
1029 \end{figure}  
1030
1031
1032
1033
1034 \subsection{The comparison of the proposed scaling algorithm }
1035 \label{sec.compare_EDP}
1036
1037 In this section, the scaling  factors selection algorithm
1038 is compared to Spiliopoulos et al. algorithm \cite{Spiliopoulos_Green.governors.Adaptive.DVFS}. 
1039 They developed a green governor that regularly applies an online frequency selecting algorithm to reduce the energy consumed by a multicore architecture without degrading much its performance. The algorithm selects the frequencies that minimize the energy and delay products, $EDP=Enegry*Delay$ using the predicted overall energy consumption and execution time delay for each frequency.
1040  To fairly compare both algorithms, the same energy and execution time models, equations (\ref{eq:energy}) and  (\ref{eq:fnew}), were used for both algorithms to predict the energy consumption and the execution times. Also Spiliopoulos et al.  algorithm was adapted to  start the search from the 
1041 initial frequencies computed using the equation (\ref{eq:Fint}). The resulting algorithm is an exhaustive search algorithm that minimizes the EDP and has the initial frequencies values as an upper bound.
1042
1043 Both algorithms were applied to the parallel NAS benchmarks to compare their efficiency. Table \ref{table:compare_EDP}  presents the results of comparing the execution times and the energy consumptions for both versions of the NAS benchmarks while running the class C of each benchmark over 8 or 9 heterogeneous nodes. \textcolor{red}{The results show that our algorithm gives better energy savings than Spiliopoulos et al. algorithm, 
1044 on average it is up to 17\% higher for  energy saving compared to their algorithm. The average of performance degradation percentage using our method is higher on average by 3.82\%. The positive values for  energy saving and distance are mean that our method outperform Spiliopoulos et al. method, while the inverse is happen for the negative values. The negative values for performance degradation percentage are mean our method is has the less delay in time, while the positive values mean the inverse. }
1045
1046 For all benchmarks, our algorithm outperforms 
1047 Spiliopoulos et al. algorithm in term of energy and performance tradeoff \textcolor{red}{(on average it has up to 21\% of distance)}, see figure (\ref{fig:compare_EDP}) because it maximizes the distance between the energy saving and the performance degradation values while giving the same weight for both metrics. 
1048
1049
1050
1051 \begin{table}[htb]
1052   \caption{Comparing the proposed algorithm}
1053   % title of Table
1054   \centering
1055   \begin{tabular}{|*{4}{l|}}
1056     \hline
1057     Program       & Energy      & Performance        & Distance\%    \\
1058     name          & saving\%    & degradation\%      &              \\
1059     \hline
1060     CG            &13.31                &22.34                   &10.89       \\
1061     \hline 
1062     MG            &14.55                &71.39                   &6.29        \\
1063    \hline
1064     EP            &44.4             &0.0                         &44.42        \\
1065    \hline
1066     LU            &-4.79                &-88.58                  &10.12     \\
1067     \hline
1068     BT            &16.76                &22.33                   &15.07     \\
1069    \hline
1070     SP            &20.52                &-46.64                  &43.37      \\
1071    \hline
1072     FT            &14.76                &-7.64                   &17.3     \\
1073 \hline 
1074   \end{tabular}
1075   \label{table:compare_EDP}
1076 \end{table}
1077
1078
1079 \begin{figure}[t]
1080   \centering
1081    \includegraphics[scale=0.5]{fig/compare_EDP.pdf}
1082   \caption{Tradeoff comparison for NAS benchmarks class C}
1083   \label{fig:compare_EDP}
1084 \end{figure}
1085
1086
1087 \section{Conclusion}
1088 \label{sec.concl} 
1089 In this paper, a new online frequency selecting algorithm has been presented. It selects the best possible vector of frequency scaling factors that gives the maximum distance (optimal tradeoff) between the predicted energy and 
1090 the predicted performance curves for a heterogeneous platform. This algorithm uses a new energy model for measuring  
1091 and predicting the energy of distributed iterative applications running over heterogeneous 
1092 platform. To evaluate the proposed method, it  was  applied on the NAS parallel benchmarks and executed over a heterogeneous platform simulated by  Simgrid. The results of the experiments showed that the algorithm reduces up to 35\% the energy consumption of a message passing iterative method while limiting the degradation of the performance. The algorithm also  selects different scaling factors   according to the percentage of the computing and communication times, and according to the values of  the static and  dynamic powers of the CPUs. Finally, the algorithm was compared to Spiliopoulos et al. algorithm and the results showed that it 
1093  outperforms their algorithm in term of energy-time tradeoff.
1094
1095 In the near future, this method will be applied to real heterogeneous platforms to evaluate its performance in a real study case. It would also be interesting to evaluate its scalability over large scale heterogeneous platform and measure the energy consumption reduction it can produce. Afterward, we would like  to develop a similar method that is adapted to asynchronous  iterative applications 
1096 where each task does not wait for others tasks to finish there works. The development of such method might require a new 
1097 energy model because the number of iterations is not 
1098 known in advance and depends on the global convergence of the iterative system.
1099
1100 \section*{Acknowledgment}
1101
1102 This work has been partially supported by the Labex
1103 ACTION project (contract “ANR-11-LABX-01-01”). As a PhD student,
1104 Mr. Ahmed Fanfakh, would like to thank the University of
1105 Babylon (Iraq) for supporting his work.
1106
1107
1108 % trigger a \newpage just before the given reference
1109 % number - used to balance the columns on the last page
1110 % adjust value as needed - may need to be readjusted if
1111 % the document is modified later
1112 %\IEEEtriggeratref{15}
1113
1114 \bibliographystyle{IEEEtran}
1115 \bibliography{IEEEabrv,my_reference}
1116 \end{document}
1117
1118 %%% Local Variables:
1119 %%% mode: latex
1120 %%% TeX-master: t
1121 %%% fill-column: 80
1122 %%% ispell-local-dictionary: "american"
1123 %%% End:
1124
1125 % LocalWords:  Fanfakh Charr FIXME Tianhe DVFS HPC NAS NPB SMPI Rauber's Rauber
1126 % LocalWords:  CMOS EPSA Franche Comté Tflop Rünger IUT Maréchal Juin cedex
1127 % LocalWords:  de badri muslim MPI TcpOld TcmOld dNew dOld cp Sopt Tcp Tcm Ps
1128 % LocalWords:  Scp Fmax Fdiff SimGrid GFlops Xeon EP BT