]> AND Private Git Repository - mpi-energy2.git/blob - Heter_paper.tex
Logo AND Algorithmique Numérique Distribuée

Private GIT Repository
corrected the abstract and the introduction. I have also put some remarks in bold
[mpi-energy2.git] / Heter_paper.tex
1 \documentclass[conference]{IEEEtran}
2
3 \usepackage[T1]{fontenc}
4 \usepackage[utf8]{inputenc}
5 \usepackage[english]{babel}
6 \usepackage{algpseudocode}
7 \usepackage{graphicx}
8 \usepackage{algorithm}
9 \usepackage{subfig}
10 \usepackage{amsmath}
11
12 \usepackage{url}
13 \DeclareUrlCommand\email{\urlstyle{same}}
14
15 \usepackage[autolanguage,np]{numprint}
16 \AtBeginDocument{%
17   \renewcommand*\npunitcommand[1]{\text{#1}}
18   \npthousandthpartsep{}}
19
20 \usepackage{xspace}
21 \usepackage[textsize=footnotesize]{todonotes}
22 \newcommand{\AG}[2][inline]{%
23   \todo[color=green!50,#1]{\sffamily\textbf{AG:} #2}\xspace}
24 \newcommand{\JC}[2][inline]{%
25   \todo[color=red!10,#1]{\sffamily\textbf{JC:} #2}\xspace}
26
27 \newcommand{\Xsub}[2]{\ensuremath{#1_\textit{#2}}}
28
29 \newcommand{\Dist}{\textit{Dist}}
30 \newcommand{\Eind}{\Xsub{E}{ind}}
31 \newcommand{\Enorm}{\Xsub{E}{Norm}}
32 \newcommand{\Eoriginal}{\Xsub{E}{Original}}
33 \newcommand{\Ereduced}{\Xsub{E}{Reduced}}
34 \newcommand{\Fdiff}{\Xsub{F}{diff}}
35 \newcommand{\Fmax}{\Xsub{F}{max}}
36 \newcommand{\Fnew}{\Xsub{F}{new}}
37 \newcommand{\Ileak}{\Xsub{I}{leak}}
38 \newcommand{\Kdesign}{\Xsub{K}{design}}
39 \newcommand{\MaxDist}{\textit{Max Dist}}
40 \newcommand{\Ntrans}{\Xsub{N}{trans}}
41 \newcommand{\Pdyn}{\Xsub{P}{dyn}}
42 \newcommand{\PnormInv}{\Xsub{P}{NormInv}}
43 \newcommand{\Pnorm}{\Xsub{P}{Norm}}
44 \newcommand{\Tnorm}{\Xsub{T}{Norm}}
45 \newcommand{\Pstates}{\Xsub{P}{states}}
46 \newcommand{\Pstatic}{\Xsub{P}{static}}
47 \newcommand{\Sopt}{\Xsub{S}{opt}}
48 \newcommand{\Tcomp}{\Xsub{T}{comp}}
49 \newcommand{\TmaxCommOld}{\Xsub{T}{Max Comm Old}}
50 \newcommand{\TmaxCompOld}{\Xsub{T}{Max Comp Old}}
51 \newcommand{\Tmax}{\Xsub{T}{max}}
52 \newcommand{\Tnew}{\Xsub{T}{New}}
53 \newcommand{\Told}{\Xsub{T}{Old}} 
54 \begin{document} 
55
56 \title{Energy Consumption Reduction in a Heterogeneous Architecture Using DVFS}
57  
58 \author{% 
59   \IEEEauthorblockN{%
60     Jean-Claude Charr,
61     Raphaël Couturier,
62     Ahmed Fanfakh and
63     Arnaud Giersch
64   } 
65   \IEEEauthorblockA{%
66     FEMTO-ST Institute\\
67     University of Franche-Comté\\
68     IUT de Belfort-Montbéliard,
69     19 avenue du Maréchal Juin, BP 527, 90016 Belfort cedex, France\\
70     % Telephone: \mbox{+33 3 84 58 77 86}, % Raphaël
71     % Fax: \mbox{+33 3 84 58 77 81}\\      % Dept Info
72     Email: \email{{jean-claude.charr,raphael.couturier,ahmed.fanfakh_badri_muslim,arnaud.giersch}@univ-fcomte.fr}
73    }
74   }
75
76 \maketitle
77
78 \begin{abstract}
79 Computing platforms are consuming more and more energy due to the increase of the number of nodes composing them. To minimize the operating costs of these platforms many techniques have been used. Dynamic voltage and frequency scaling (DVFS) is one of them, it reduces the frequency of a CPU to lower its energy consumption. However, lowering the frequency of a CPU might increase the execution time of an application running on that processor. Therefore, the frequency that gives the best  tradeoff between the energy consumption and the performance of an application must be selected. 
80
81 In this paper, a new online frequencies selecting algorithm for heterogeneous platforms is presented. It selects the frequency that gives  the best tradeoff between energy saving and
82 performance degradation, for each node computing the message passing iterative application. The algorithm has a small overhead and works without training or profiling.
83 It uses a new energy model for message passing iterative applications running on a heterogeneous platform. 
84 The proposed algorithm was evaluated  on the Simgrid simulator while running the NAS parallel benchmarks.
85 The experiments demonstrated that it reduces the energy consumption up to 35\% while limiting the performance degradation as much as possible.
86 \end{abstract}
87
88 \section{Introduction}
89 \label{sec.intro}
90 The need for more computing power is continually increasing. To partially satisfy this need, most supercomputers constructors just put more computing nodes in their platform. The resulting platform might achieve higher floating point operations per second (FLOPS), but the energy consumption and the heat dissipation are also increased. As an example, the chinese supercomputer Tianhe-2 had the highest FLOPS in November 2014 according to the Top500 list \cite{TOP500_Supercomputers_Sites}.  However, it was also the  most power hungry platform with its over 3 millions cores consuming around 17.8 megawatts.
91 Moreover, according to the U.S. annual energy outlook 2014 
92 \cite{U.S_Annual.Energy.Outlook.2014}, the price of energy for 1 megawatt-hour 
93 was approximately equal to \$70. 
94 Therefore, the price of the energy consumed by the 
95 Tianhe-2 platform is approximately more than \$10 millions each year. 
96 The computing platforms must be more energy efficient and offer the highest number of FLOPS per watt possible, such as the TSUBAME-KFC at the GSIC center of Tokyo which  
97 became the top of the Green500 list in June 2014 \cite{Green500_List}. 
98 This heterogeneous platform executes more than four  GFLOPS per watt.
99
100  Besides hardware improvements, there are many software techniques to lower the energy consumption of these platforms, such as scheduling, DVFS, ... DVFS is a widely  used process to reduce the energy 
101 consumption of a processor by lowering its frequency. \textbf{put a reference to DVFS} However, it also the reduces the number of FLOPS executed by the processor which might increase the execution time of the application running over that processor.
102 Therefore,  researchers used different optimization strategies to select the frequency that gives the best tradeoff   between the energy reduction and 
103 performance degradation ratio.
104 \textbf{you should talk about the first paper here and say that the algorithm was applied to a homogeneous platform then define what is a heterogeneous platform, you can take it from the firdt paragraph in section 3 }
105
106 In this paper, a frequency selecting algorithm is proposed. It  selects the vector of frequencies for a heterogeneous platform that runs a message passing iterative application,  that gives the maximum energy reduction and minimum 
107 performance degradation ratio simultaneously. The algorithm has a very small 
108 overhead, works online and does not need any training or profiling.  
109
110 This paper is organized as follows: Section~\ref{sec.relwork} presents some
111 related works from other authors.  Section~\ref{sec.exe} describes how the
112 execution time of message passing programs can be predicted.  It also presents an energy
113 model that predicts the energy consumption of an application running over a heterogeneous platform. Section~\ref{sec.compet} presents
114 the energy-performance objective function that maximizes the reduction of energy
115 consumption while minimizing the degradation of the program's performance.
116 Section~\ref{sec.optim} details the proposed frequency selecting algorithm then the precision of the proposed algorithm is verified.\textbf{the verification should be put here}  
117 Section~\ref{sec.expe} presents the results of applying the algorithm on  the NAS parallel benchmarks and executing them 
118 on a heterogeneous platform. It also shows the results of running three 
119 different power scenarios and comparing them. 
120 Finally, we conclude in Section~\ref{sec.concl} with a summary and some future works.
121
122 \textbf{never use we in an article and the algorithm is not heterogeneous! you cannot use scaling factors before defining what they are.}
123 \section{Related works}
124 \label{sec.relwork}
125 Energy reduction process for high performance clusters recently performed using 
126 dynamic voltage and frequency scaling (DVFS) technique. DVFS is a technique enabled 
127 in modern processors to scaled down both of the voltage and the frequency of 
128 the CPU while it is in the computing mode to reduce the energy consumption. DVFS is 
129 also  allowed in the graphical processors GPUs, to achieved the same goal. Applying 
130 DVFS has a dramatical side effect if it is applied to minimum levels to gain more 
131 energy reduction, producing  a high percentage of performance degradations for the 
132 parallel applications.  Many researchers used different strategies to solve this 
133 nonlinear problem for example in
134 ~\cite{Hao_Learning.based.DVFS,Dhiman_Online.Learning.Power.Management}, their methods 
135 add big overheads to the algorithm to select the suitable frequency.  
136 In this paper we  present a method 
137 to find the optimal set of frequency scaling factors for heterogeneous cluster to 
138 simultaneously optimize both the energy and the execution time  without adding big 
139 overhead. This work is developed from our previous work of homogeneous cluster~\cite{Our_first_paper}. 
140 Therefore we are interested to present some works that concerned the heterogeneous clusters 
141 enabled DVFS. In general, the heterogeneous cluster works fall into two categorizes: 
142 GPUs-CPUs heterogeneous clusters and CPUs-CPUs heterogeneous clusters. In GPUs-CPUs 
143 heterogeneous clusters some parallel tasks executed on  GPUs and the others executed 
144 on  CPUs. As an example of this works, Luley et al.
145 ~\cite{Luley_Energy.efficiency.evaluation.and.benchmarking}, proposed  a heterogeneous 
146 cluster composed of Intel Xeon CPUs and NVIDIA GPUs. Their main goal is to determined the 
147 energy efficiency as a function of performance per watt, the best tradeoff is done when the 
148 performance per watt function is maximized. In the work of Kia Ma et al.
149 ~\cite{KaiMa_Holistic.Approach.to.Energy.Efficiency.in.GPU-CPU}, they developed a scheduling 
150 algorithm to distributed different workloads proportional to the computing power of the node 
151 to be executed on CPU or GPU, emphasize all tasks must be finished in the same time. 
152 Recently, Rong et al.~\cite{Rong_Effects.of.DVFS.on.K20.GPU}, Their study explain that 
153 a heterogeneous clusters enabled DVFS using GPUs and CPUs gave better energy and performance 
154 efficiency than other clusters composed of only CPUs. 
155 The CPUs-CPUs heterogeneous clusters consist of number of computing nodes  all of the type CPU. 
156 Our work in this paper can be classified to this type of the clusters. 
157 As an example of these works see  Naveen et al.~\cite{Naveen_Power.Efficient.Resource.Scaling} work, 
158 They developed a policy to dynamically assigned the frequency to a heterogeneous cluster. 
159 The goal is to minimizing a fixed metric of $energy*delay^2$. Where our proposed method is automatically 
160 optimized  the relation between the energy and the delay of the iterative applications. 
161 Other works such as Lizhe et al.~\cite{Lizhe_Energy.aware.parallel.task.scheduling}, 
162 their algorithm divided the executed tasks into two types: the critical and 
163 non critical tasks. The algorithm scaled down the frequency of the non critical tasks 
164 as function to the  amount of the slack and communication times that 
165 have with maximum of performance degradation percentage less than 10\%. In our method there is no 
166 fixed bounds for performance degradation percentage and the bound is dynamically computed 
167 according to the energy and the performance tradeoff relation of the executed application. 
168 There are some approaches used a heterogeneous cluster composed from two different types 
169 of Intel and AMD processors such as~\cite{Joshi_Blackbox.prediction.of.impact.of.DVFS} 
170 and \cite{Spiliopoulos_Green.governors.Adaptive.DVFS}, they predicated  both the energy 
171 and the performance for each frequency gear, then the algorithm selected the best gear that gave 
172 the best tradeoff. In contrast our algorithm works over a heterogeneous  platform composed of 
173 four different types of processors. Others approaches such as 
174 \cite{Shelepov_Scheduling.on.Heterogeneous.Multicore} and \cite{Li_Minimizing.Energy.Consumption.for.Frame.Based.Tasks}, 
175 they are selected the best frequencies for a specified heterogeneous clusters offline using some 
176 heuristic methods. While our proposed algorithm works online during the execution time of 
177 iterative application. Greedy dynamic approach used by Chen et al.~\cite{Chen_DVFS.under.quality.of.service.requirements},  
178 minimized the power consumption of a heterogeneous severs  with time/space complexity, this approach 
179 had considerable overhead. In our proposed scaling algorithm has very small overhead and 
180 it is works without any previous analysis for the application time complexity. The primary 
181 contributions of our paper are :
182 \begin{enumerate}
183 \item It is presents  a new online heterogeneous scaling algorithm which has very small 
184       overhead and not need for any training and profiling.
185 \item It is develops a new energy model for iterative distributed applications running over 
186        a heterogeneous clusters, taking into account the communication and slack times.
187 \item The proposed scaling algorithm predicts both the energy and the execution time 
188       of the iterative application.
189 \item It demonstrates a new optimization function which maximize the performance and 
190       minimize the energy consumption simultaneously.
191       
192 \end{enumerate}
193
194 \section{The performance and energy consumption measurements on heterogeneous architecture}
195 \label{sec.exe}
196
197 % \JC{The whole subsection ``Parallel Tasks Execution on Homogeneous Platform'',
198 %   can be deleted if we need space, we can just say we are interested in this
199 %   paper in homogeneous clusters}
200
201 \subsection{The execution time of message passing distributed 
202                 iterative applications on a heterogeneous platform}
203
204 In this paper, we are interested in reducing the energy consumption of message
205 passing distributed iterative synchronous applications running over
206 heterogeneous platforms. We define a heterogeneous platform as a collection of
207 heterogeneous computing nodes interconnected via a high speed homogeneous
208 network. Therefore, each node has different characteristics such as computing
209 power (FLOPS), energy consumption, CPU's frequency range, \dots{} but they all
210 have the same network bandwidth and latency.
211
212 The overall execution time  of a distributed iterative synchronous application 
213 over a heterogeneous platform  consists of the sum of the computation time and 
214 the communication time for every iteration on a node. However, due to the 
215 heterogeneous computation power of the computing nodes, slack times might occur 
216 when fast nodes have to  wait, during synchronous communications, for  the slower 
217 nodes to finish  their computations (see Figure~(\ref{fig:heter})). 
218 Therefore,  the overall execution time  of the program is the execution time of the slowest
219 task which have the highest computation time and no slack time.
220   
221  \begin{figure}[t]
222   \centering
223     \includegraphics[scale=0.6]{fig/commtasks}
224   \caption{Parallel tasks on a heterogeneous platform}
225   \label{fig:heter}
226 \end{figure}
227
228 Dynamic Voltage and Frequency Scaling (DVFS) is a process, implemented in 
229 modern processors, that reduces the energy consumption of a CPU by scaling 
230 down its voltage and frequency.  Since DVFS lowers the frequency of a CPU 
231 and consequently its computing power, the execution time of a program running 
232 over that scaled down processor might increase, especially if the program is 
233 compute bound.  The frequency reduction process can be  expressed by the scaling 
234 factor S which is the ratio between  the maximum and the new frequency of a CPU 
235 as in EQ (\ref{eq:s}).
236 \begin{equation}
237   \label{eq:s}
238  S = \frac{F_\textit{max}}{F_\textit{new}}
239 \end{equation}
240  The execution time of a compute bound sequential program is linearly proportional 
241  to the frequency scaling factor $S$.  On the other hand,  message passing 
242  distributed applications consist of two parts: computation and communication. 
243  The execution time of the computation part is linearly proportional to the 
244  frequency scaling factor $S$ but  the communication time is not affected by the 
245  scaling factor because  the processors involved remain idle during the  
246  communications~\cite{Freeh_Exploring.the.Energy.Time.Tradeoff}. 
247  The communication time for a task is the summation of  periods of 
248  time that begin with an MPI call for sending or receiving   a message 
249  till the message is synchronously sent or received.
250
251 Since in a heterogeneous platform, each node has different characteristics,
252 especially different frequency gears, when applying DVFS operations on these
253 nodes, they may get different scaling factors represented by a scaling vector:
254 $(S_1, S_2,\dots, S_N)$ where $S_i$ is the scaling factor of processor $i$. To
255 be able to predict the execution time of message passing synchronous iterative
256 applications running over a heterogeneous platform, for different vectors of
257 scaling factors, the communication time and the computation time for all the
258 tasks must be measured during the first iteration before applying any DVFS
259 operation. Then the execution time for one iteration of the application with any
260 vector of scaling factors can be predicted using EQ (\ref{eq:perf}).
261 \begin{equation}
262   \label{eq:perf}
263  \textit  T_\textit{new} = 
264  \max_{i=1,2,\dots,N} ({TcpOld_{i}} \cdot S_{i}) +  MinTcm
265 \end{equation}
266 where $TcpOld_i$ is the computation time  of processor $i$ during the first 
267 iteration and $MinTcm$ is the communication time of the slowest processor from 
268 the first iteration.  The model computes the maximum computation time 
269 with scaling factor from each node  added to the communication time of the 
270 slowest node, it means  only the  communication time without any slack time. 
271 Therefore, we can consider the execution time of the iterative application is 
272 equal to the execution time of one iteration as in EQ(\ref{eq:perf}) multiplied 
273 by the number of iterations of that application.
274
275 This prediction model is developed from our model for predicting the execution time of 
276 message passing distributed applications for homogeneous architectures~\cite{Our_first_paper}. 
277 The execution time prediction model is used in our method for optimizing both 
278 energy consumption and performance of iterative methods, which is presented in the 
279 following sections.
280
281
282 \subsection{Energy model for heterogeneous platform}
283 Many researchers~\cite{Malkowski_energy.efficient.high.performance.computing,
284 Rauber_Analytical.Modeling.for.Energy,Zhuo_Energy.efficient.Dynamic.Task.Scheduling,
285 Rizvandi_Some.Observations.on.Optimal.Frequency} divide the power consumed by a processor into
286 two power metrics: the static and the dynamic power.  While the first one is
287 consumed as long as the computing unit is turned on, the latter is only consumed during
288 computation times.  The dynamic power $Pd$ is related to the switching
289 activity $\alpha$, load capacitance $C_L$, the supply voltage $V$ and
290 operational frequency $F$, as shown in EQ(\ref{eq:pd}).
291 \begin{equation}
292   \label{eq:pd}
293   Pd = \alpha \cdot C_L \cdot V^2 \cdot F
294 \end{equation}
295 The static power $Ps$ captures the leakage power as follows:
296 \begin{equation}
297   \label{eq:ps}
298    Ps  = V \cdot N_{trans} \cdot K_{design} \cdot I_{leak}
299 \end{equation}
300 where V is the supply voltage, $N_{trans}$ is the number of transistors,
301 $K_{design}$ is a design dependent parameter and $I_{leak}$ is a
302 technology-dependent parameter.  The energy consumed by an individual processor
303 to execute a given program can be computed as:
304 \begin{equation}
305   \label{eq:eind}
306    E_\textit{ind} =  Pd \cdot Tcp + Ps \cdot T
307 \end{equation}
308 where $T$ is the execution time of the program, $Tcp$ is the computation
309 time and $Tcp \leq T$.  $Tcp$ may be equal to $T$ if there is no
310 communication and no slack time.
311
312 The main objective of DVFS operation is to reduce the overall energy consumption~\cite{Le_DVFS.Laws.of.Diminishing.Returns}.  
313 The operational frequency $F$ depends linearly on the supply voltage $V$, i.e., $V = \beta \cdot F$ with some
314 constant $\beta$.  This equation is used to study the change of the dynamic
315 voltage with respect to various frequency values in~\cite{Rauber_Analytical.Modeling.for.Energy}.  The reduction
316 process of the frequency can be expressed by the scaling factor $S$ which is the
317 ratio between the maximum and the new frequency as in EQ(\ref{eq:s}).
318 The CPU governors are power schemes supplied by the operating
319 system's kernel to lower a core's frequency. we can calculate the new frequency 
320 $F_{new}$ from EQ(\ref{eq:s}) as follow:
321 \begin{equation}
322   \label{eq:fnew}
323    F_\textit{new} = S^{-1} \cdot F_\textit{max}
324 \end{equation}
325 Replacing $F_{new}$ in EQ(\ref{eq:pd}) as in EQ(\ref{eq:fnew}) gives the following 
326 equation for dynamic power consumption:
327 \begin{multline}
328   \label{eq:pdnew}
329    {P}_\textit{dNew} = \alpha \cdot C_L \cdot V^2 \cdot F_{new} = \alpha \cdot C_L \cdot \beta^2 \cdot F_{new}^3 \\
330    {} = \alpha \cdot C_L \cdot V^2 \cdot F_{max} \cdot S^{-3} = P_{dOld} \cdot S^{-3}
331 \end{multline}
332 where $ {P}_\textit{dNew}$  and $P_{dOld}$ are the  dynamic power consumed with the 
333 new frequency and the maximum frequency respectively.
334
335 According to EQ(\ref{eq:pdnew}) the dynamic power is reduced by a factor of $S^{-3}$ when 
336 reducing the frequency by a factor of $S$~\cite{Rauber_Analytical.Modeling.for.Energy}. Since the FLOPS of a CPU is proportional 
337 to the frequency of a CPU, the computation time is increased proportionally to $S$.  
338 The new dynamic energy is the  dynamic power multiplied by the new time of computation 
339 and is given by the following equation:
340 \begin{equation}
341   \label{eq:Edyn}
342    E_\textit{dNew} = P_{dOld} \cdot S^{-3} \cdot (Tcp \cdot S)= S^{-2}\cdot P_{dOld} \cdot  Tcp 
343 \end{equation}
344 The static power is related to the power leakage of the CPU and is consumed during computation 
345 and even when idle. As in~\cite{Rauber_Analytical.Modeling.for.Energy,Zhuo_Energy.efficient.Dynamic.Task.Scheduling}, 
346 we assume that the static power of a processor is constant 
347 during idle and computation periods, and for all its available frequencies. 
348 The static energy is the static power multiplied by the execution time of the program. 
349 According to the execution time model in EQ(\ref{eq:perf}), the execution time of the program 
350 is the summation of the computation and the communication times. The computation time is linearly related  
351 to the frequency scaling factor, while this scaling factor does not affect the communication time. 
352 The static energy of a processor after scaling its frequency is computed as follows: 
353 \begin{equation}
354   \label{eq:Estatic}
355  E_\textit{s} = Ps \cdot (Tcp \cdot S  + Tcm)
356 \end{equation}
357
358 In the considered heterogeneous platform, each processor $i$ might have different dynamic and 
359 static powers, noted as $Pd_{i}$ and $Ps_{i}$ respectively. Therefore, even if the distributed 
360 message passing iterative application is load balanced, the computation time of each CPU $i$ 
361 noted $Tcp_{i}$ might be different and different frequency  scaling factors might be computed 
362 in order to decrease the overall energy consumption of the application and reduce the slack times. 
363 The communication time of a processor $i$ is noted as $Tcm_{i}$ and could contain slack times 
364 if it is communicating with slower nodes, see figure(\ref{fig:heter}). Therefore, all nodes do 
365 not have equal communication times. While the dynamic energy is computed according to the frequency 
366 scaling factor and the dynamic power of each node as in EQ(\ref{eq:Edyn}), the static energy is 
367 computed as the sum of the execution time of each processor multiplied by its static power. 
368 The overall energy consumption of a message passing  distributed application executed over a 
369 heterogeneous platform during one iteration is the summation of all dynamic and static energies 
370 for each  processor.  It is computed as follows:
371 \begin{multline}
372   \label{eq:energy}
373  E = \sum_{i=1}^{N} {(S_i^{-2} \cdot Pd_{i} \cdot  Tcp_i)} + {} \\
374  \sum_{i=1}^{N} (Ps_{i} \cdot (\max_{i=1,2,\dots,N} (Tcp_i \cdot S_{i}) +
375   {MinTcm))}
376  \end{multline}
377
378 Reducing the frequencies of the processors according to the vector of
379 scaling factors $(S_1, S_2,\dots, S_N)$ may degrade the performance of the
380 application and thus, increase the static energy because the execution time is
381 increased~\cite{Kim_Leakage.Current.Moore.Law}. We can measure the overall energy consumption for the iterative 
382 application by measuring  the energy consumption for one iteration as in EQ(\ref{eq:energy}) 
383 multiplied by the number of iterations of that application.
384
385
386 \section{Optimization of both energy consumption and performance}
387 \label{sec.compet}
388
389 Using the lowest frequency for each processor does not necessarily gives the most energy 
390 efficient execution of an application. Indeed, even though the dynamic power is reduced 
391 while scaling down the frequency of a processor, its computation power is proportionally 
392 decreased and thus the execution time might be drastically increased during which dynamic 
393 and static powers are being consumed. Therefore,  it might cancel any gains achieved by 
394 scaling down the frequency of all nodes to the minimum  and the overall energy consumption 
395 of the application might not be the optimal one. It is not trivial to select the appropriate 
396 frequency scaling factor for each processor while considering the characteristics of each processor 
397 (computation power, range of frequencies, dynamic and static powers) and the task executed 
398 (computation/communication ratio) in order to reduce the overall energy consumption and not 
399 significantly increase the execution time. In our previous work~\cite{Our_first_paper}, we  proposed a method 
400 that selects the optimal frequency scaling factor for a homogeneous cluster executing a message 
401 passing iterative synchronous application while giving the best trade-off  between the energy 
402 consumption and the performance for such applications. In this work we are interested in 
403 heterogeneous clusters as described above. Due to the heterogeneity of the processors, not 
404 one but a  vector of scaling factors should be selected and it must  give the best trade-off 
405 between energy consumption and performance. 
406
407 The relation between the energy consumption and the execution time for an application is 
408 complex and nonlinear, Thus, unlike the relation between the execution time 
409 and the scaling factor, the relation of the energy with the frequency scaling
410 factors is nonlinear, for more details refer to~\cite{Freeh_Exploring.the.Energy.Time.Tradeoff}.  
411 Moreover, they are not measured using the same metric.  To solve this problem, we normalize the
412 execution time by computing the ratio between the new execution time (after 
413 scaling down the frequencies of some processors) and the initial one (with maximum 
414 frequency for all nodes,) as follows:
415 \begin{multline}
416   \label{eq:pnorm}
417   P_\textit{Norm} = \frac{T_\textit{New}}{T_\textit{Old}}\\
418        {} = \frac{ \max_{i=1,2,\dots,N} (Tcp_{i} \cdot S_{i}) +MinTcm}
419            {\max_{i=1,2,\dots,N}{(Tcp_i+Tcm_i)}}
420 \end{multline}
421
422
423 In the same way, we normalize the energy by computing the ratio between the consumed energy 
424 while scaling down the frequency and the consumed energy with maximum frequency for all nodes:
425 \begin{multline}
426   \label{eq:enorm}
427   E_\textit{Norm} = \frac{E_\textit{Reduced}}{E_\textit{Original}} \\
428   {} = \frac{ \sum_{i=1}^{N}{(S_i^{-2} \cdot Pd_i \cdot  Tcp_i)} +
429  \sum_{i=1}^{N} {(Ps_i \cdot T_{New})}}{\sum_{i=1}^{N}{( Pd_i \cdot  Tcp_i)} +
430  \sum_{i=1}^{N} {(Ps_i \cdot T_{Old})}}
431 \end{multline} 
432 Where $T_{New}$ and $T_{Old}$ are computed as in EQ(\ref{eq:pnorm}).
433
434  While the main 
435 goal is to optimize the energy and execution time at the same time, the normalized 
436 energy and execution time curves are not in the same direction. According 
437 to the equations~(\ref{eq:enorm}) and~(\ref{eq:pnorm}), the vector  of frequency
438 scaling factors $S_1,S_2,\dots,S_N$ reduce both the energy and the execution
439 time simultaneously.  But the main objective is to produce maximum energy
440 reduction with minimum execution time reduction.  
441
442  
443   
444 Our solution for this problem is to make the optimization process for energy and 
445 execution time follow the same direction.  Therefore, we inverse the equation of the 
446 normalized execution time which gives the normalized performance equation, as follows:
447 \begin{multline}
448   \label{eq:pnorm_inv}
449   P_\textit{Norm} = \frac{T_\textit{Old}}{T_\textit{New}}\\
450           = \frac{\max_{i=1,2,\dots,N}{(Tcp_i+Tcm_i)}}
451             { \max_{i=1,2,\dots,N} (Tcp_{i} \cdot S_{i}) + MinTcm} 
452 \end{multline}
453
454
455 \begin{figure}
456   \centering
457   \subfloat[Homogeneous platform]{%
458     \includegraphics[width=.22\textwidth]{fig/homo}\label{fig:r1}}%
459   \qquad%
460   \subfloat[Heterogeneous platform]{%
461     \includegraphics[width=.22\textwidth]{fig/heter}\label{fig:r2}}
462   \label{fig:rel}
463   \caption{The energy and performance relation}
464 \end{figure}
465
466 Then, we can model our objective function as finding the maximum distance
467 between the energy curve EQ~(\ref{eq:enorm}) and the  performance
468 curve EQ~(\ref{eq:pnorm_inv}) over all available sets of scaling factors.  This
469 represents the minimum energy consumption with minimum execution time (maximum 
470 performance) at the same time, see figure~(\ref{fig:r1}) or figure~(\ref{fig:r2}). Then our objective
471 function has the following form:
472 \begin{equation}
473   \label{eq:max}
474   Max Dist = 
475   \max_{i=1,\dots F, j=1,\dots,N}
476       (\overbrace{P_\textit{Norm}(S_{ij})}^{\text{Maximize}} -
477        \overbrace{E_\textit{Norm}(S_{ij})}^{\text{Minimize}} )
478 \end{equation}
479 where $N$ is the number of nodes and $F$ is the  number of available frequencies for each nodes. 
480 Then we can select the optimal set of scaling factors that satisfies EQ~(\ref{eq:max}).  
481 Our objective function can work with any energy model or any power values for each node 
482 (static and dynamic powers). However, the most energy reduction gain can be achieved when 
483 the energy curve has a convex form as shown in~\cite{Zhuo_Energy.efficient.Dynamic.Task.Scheduling,Rauber_Analytical.Modeling.for.Energy,Hao_Learning.based.DVFS}.
484
485 \section{The scaling factors selection algorithm for heterogeneous platforms }
486 \label{sec.optim}
487
488 In this section we  propose algorithm~(\ref{HSA}) which selects the frequency scaling factors 
489 vector that gives the best trade-off between minimizing the energy consumption  and maximizing 
490 the performance of a message passing synchronous iterative application executed on a heterogeneous 
491 platform. It works online during the execution time of the iterative message passing program.  
492 It uses information gathered during the first iteration such as the computation time and the 
493 communication time in one iteration for each node. The algorithm is executed  after the first 
494 iteration and returns a vector of optimal frequency scaling factors   that satisfies the objective 
495 function EQ(\ref{eq:max}). The program apply DVFS operations to change the frequencies of the CPUs 
496 according to the computed scaling factors.  This algorithm is called just once during the execution 
497 of the program. Algorithm~(\ref{dvfs}) shows where and when the proposed scaling algorithm is called 
498 in the iterative MPI program.
499
500 The nodes in a heterogeneous platform have different computing powers, thus while executing message 
501 passing iterative synchronous applications, fast nodes have to wait for the slower ones to finish their 
502 computations before being able to synchronously communicate with them as in figure (\ref{fig:heter}). 
503 These periods are called idle or slack times. 
504 Our algorithm takes into account this problem and tries to reduce these slack times when selecting the 
505 frequency scaling factors vector. At first, it selects initial frequency scaling factors that increase 
506 the execution times of fast nodes and  minimize the  differences between  the  computation times of 
507 fast and slow nodes. The value of the initial frequency scaling factor  for each node is inversely 
508 proportional to its computation time that was gathered from the first iteration. These initial frequency 
509 scaling factors are computed as   a ratio between the computation time of the slowest node and the 
510 computation time of the node $i$ as follows:
511 \begin{equation}
512   \label{eq:Scp}
513  Scp_{i} = \frac{\max_{i=1,2,\dots,N}(Tcp_i)}{Tcp_i}
514 \end{equation}
515 Using the initial  frequency scaling factors computed in EQ(\ref{eq:Scp}), the algorithm computes 
516 the initial frequencies for all nodes as a ratio between the maximum frequency of node $i$  
517 and the computation scaling factor $Scp_i$ as follows:
518 \begin{equation}
519   \label{eq:Fint}
520  F_{i} = \frac{Fmax_i}{Scp_i},~{i=1,2,\cdots,N}
521 \end{equation}
522 If the computed initial frequency for a node is not available in the gears of that node, the computed 
523 initial frequency is replaced by the nearest available frequency. In  figure (\ref{fig:st_freq}), 
524 the nodes are  sorted by their computing powers in ascending order and the frequencies of the faster 
525 nodes are scaled down according to the computed initial frequency scaling factors. The resulting new 
526 frequencies are colored in blue in  figure (\ref{fig:st_freq}). This set of frequencies can be considered 
527 as a higher bound for the search space of the optimal vector of frequencies because selecting frequency 
528 scaling factors higher than the higher bound will not improve the performance of the application and 
529 it will increase its overall energy consumption. Therefore the algorithm that selects the frequency 
530 scaling factors starts the search method from these initial frequencies and takes a downward search direction 
531 toward lower frequencies. The algorithm iterates on all left frequencies, from the higher bound until all 
532 nodes reach their minimum frequencies, to compute their overall energy consumption and performance, and select 
533 the optimal frequency scaling factors vector. At each iteration the algorithm determines the slowest node 
534 according to EQ(\ref{eq:perf}) and keeps its frequency unchanged, while it lowers the frequency of  
535 all other nodes by one gear.
536 The new overall energy consumption and execution time are computed according to the new scaling factors. 
537 The optimal set of frequency scaling factors is the set that gives the highest distance according to  the objective 
538 function EQ(\ref{eq:max}).
539
540 The plots~(\ref{fig:r1} and \ref{fig:r2}) illustrate the normalized performance and consumed energy for an 
541 application running on a homogeneous platform and a heterogeneous platform respectively while increasing the 
542 scaling factors. It can be noticed that in a homogeneous platform the search for the optimal scaling factor 
543 should be started from the maximum frequency because the performance and the consumed energy is decreased since  
544 the beginning of the plot. On the other hand, in  the heterogeneous platform the performance is  maintained at 
545 the beginning of the plot even if the frequencies of the faster nodes are decreased until the scaled down nodes 
546 have computing powers lower than the slowest node. In other words, until they reach the higher bound. It can 
547 also be noticed that the higher the difference between the faster nodes and the slower nodes is, the bigger 
548 the maximum distance between the energy curve and the performance curve is while varying the scaling factors 
549 which results in bigger energy savings. 
550 \begin{figure}[t]
551   \centering
552     \includegraphics[scale=0.5]{fig/start_freq}
553   \caption{Selecting the initial frequencies}
554   \label{fig:st_freq}
555 \end{figure}
556
557
558
559
560 \begin{algorithm}
561   \begin{algorithmic}[1]
562     % \footnotesize
563     \Require ~
564     \begin{description}
565     \item[$Tcp_i$] array of all computation times for all nodes during one iteration and with highest frequency.
566     \item[$Tcm_i$] array of all communication times for all nodes during one iteration and with highest frequency.
567     \item[$Fmax_i$] array of the maximum frequencies for all nodes.
568     \item[$Pd_i$] array of the dynamic powers for all nodes.
569     \item[$Ps_i$] array of the static powers for all nodes.
570     \item[$Fdiff_i$] array of the difference between two successive frequencies for all nodes.
571     \end{description}
572     \Ensure $Sopt_1,Sopt_2 \dots, Sopt_N$ is a vector of optimal scaling factors
573
574     \State $ Scp_i \gets \frac{\max_{i=1,2,\dots,N}(Tcp_i)}{Tcp_i} $
575     \State $F_{i} \gets  \frac{Fmax_i}{Scp_i},~{i=1,2,\cdots,N}$
576     \State Round the computed initial frequencies $F_i$ to the closest one available in each node.
577     \If{(not the first frequency)}
578           \State $F_i \gets F_i+Fdiff_i,~i=1,\dots,N.$
579     \EndIf 
580     \State $T_\textit{Old} \gets max_{~i=1,\dots,N } (Tcp_i+Tcm_i)$
581     \State $E_\textit{Original} \gets \sum_{i=1}^{N}{( Pd_i \cdot  Tcp_i)} +\sum_{i=1}^{N} {(Ps_i \cdot T_{Old})}$
582     \State $Dist \gets 0$
583     \State  $Sopt_{i} \gets 1,~i=1,\dots,N. $
584     \While {(all nodes not reach their  minimum  frequency)}
585         \If{(not the last freq. \textbf{and} not the slowest node)}
586         \State $F_i \gets F_i - Fdiff_i,~i=1,\dots,N.$
587         \State $S_i \gets \frac{Fmax_i}{F_i},~i=1,\dots,N.$
588         \EndIf
589        \State $T_{New} \gets max_\textit{~i=1,\dots,N} (Tcp_{i} \cdot S_{i}) + MinTcm $
590        \State $E_\textit{Reduced} \gets \sum_{i=1}^{N}{(S_i^{-2} \cdot Pd_i \cdot  Tcp_i)} + $  \hspace*{43 mm} 
591                $\sum_{i=1}^{N} {(Ps_i \cdot T_{New})} $
592        \State $ P_\textit{Norm} \gets \frac{T_\textit{Old}}{T_\textit{New}}$
593        \State $E_\textit{Norm}\gets \frac{E_\textit{Reduced}}{E_\textit{Original}}$
594       \If{$(\Pnorm - \Enorm > \Dist)$}
595         \State $Sopt_{i} \gets S_{i},~i=1,\dots,N. $
596         \State $\Dist \gets \Pnorm - \Enorm$
597       \EndIf
598     \EndWhile
599     \State  Return $Sopt_1,Sopt_2,\dots,Sopt_N$
600   \end{algorithmic}
601   \caption{Heterogeneous scaling algorithm}
602   \label{HSA}
603 \end{algorithm}
604
605 \begin{algorithm}
606   \begin{algorithmic}[1]
607     % \footnotesize
608     \For {$k=1$ to \textit{some iterations}}
609       \State Computations section.
610       \State Communications section.
611       \If {$(k=1)$}
612         \State Gather all times of computation and\newline\hspace*{3em}%
613                communication from each node.
614         \State Call algorithm from Figure~\ref{HSA} with these times.
615         \State Compute the new frequencies from the\newline\hspace*{3em}%
616                returned optimal scaling factors.
617         \State Set the new frequencies to nodes.
618       \EndIf
619     \EndFor
620   \end{algorithmic}
621   \caption{DVFS algorithm}
622   \label{dvfs}
623 \end{algorithm}
624
625 \section{Experimental results}
626 \label{sec.expe}
627 To evaluate the efficiency and the overall energy consumption reduction of algorithm~(\ref{HSA}), 
628 it was applied to the NAS parallel benchmarks NPB v3.3  \cite{NAS.Parallel.Benchmarks}. The experiments were executed 
629 on the simulator SimGrid/SMPI v3.10~\cite{casanova+giersch+legrand+al.2014.versatile} which offers 
630 easy tools to create a heterogeneous platform and run message passing applications over it. The 
631 heterogeneous platform that was used in the experiments, had one core per node because just one 
632 process was executed per node. The heterogeneous platform  was composed of four types of nodes. 
633 Each type of nodes had different characteristics such as the maximum CPU frequency, the number of
634 available frequencies and the computational power, see table (\ref{table:platform}). The characteristics 
635 of these different types of  nodes are inspired   from the specifications of real Intel processors. 
636 The heterogeneous platform had up to 144 nodes and had nodes from the four types in equal proportions, 
637 for example if  a benchmark was executed on 8 nodes, 2 nodes from each type were used. Since the constructors 
638 of CPUs do not specify the dynamic and the static power of their CPUs, for each type of node they were 
639 chosen proportionally to its computing power (FLOPS).  In the initial heterogeneous platform,  while computing 
640 with highest frequency, each node  consumed power proportional to its computing power which 80\% of it was 
641 dynamic power and the rest was 20\% for the static power, the same assumption  was made in \cite{Our_first_paper,Rauber_Analytical.Modeling.for.Energy}. 
642 Finally, These nodes were connected via an ethernet network with 1 Gbit/s bandwidth.
643
644
645 \begin{table}[htb]
646   \caption{Heterogeneous nodes characteristics}
647   % title of Table
648   \centering
649   \begin{tabular}{|*{7}{l|}}
650     \hline
651     Node          &Simulated  & Max      & Min          & Diff.          & Dynamic      & Static \\
652     type          &GFLOPS     & Freq.    & Freq.        & Freq.          & power        & power \\
653                   &           & GHz      & GHz          &GHz             &              &       \\
654     \hline
655     1             &40         & 2.5      & 1.2          & 0.1            & 20~w         &4~w    \\
656                   &           &          &              &                &              &  \\
657     \hline
658     2             &50         & 2.66     & 1.6          & 0.133          & 25~w         &5~w    \\
659                   &           &          &              &                &              &  \\
660     \hline
661     3             &60         & 2.9      & 1.2          & 0.1            & 30~w         &6~w    \\
662                   &           &          &              &                &              &  \\
663     \hline
664     4             &70         & 3.4      & 1.6          & 0.133          & 35~w         &7~w    \\
665                   &           &          &              &                &              &  \\
666     \hline
667   \end{tabular}
668   \label{table:platform}
669 \end{table}
670
671  
672 %\subsection{Performance prediction verification}
673
674
675 \subsection{The experimental results of the scaling algorithm}
676 \label{sec.res}
677
678
679 The proposed algorithm was applied to the seven parallel NAS benchmarks (EP, CG, MG, FT, BT, LU and SP) 
680 and the benchmarks were executed with the three classes: A,B and C. However, due to the lack of space in 
681 this paper, only the results of the biggest class, C, are presented while being run on different number 
682 of nodes, ranging  from 4 to 128 or 144 nodes depending on the benchmark being executed. Indeed, the 
683 benchmarks CG, MG, LU, EP and FT should be executed on $1, 2, 4, 8, 16, 32, 64, 128$ nodes. 
684 The other benchmarks such as BT and SP should be executed on $1, 4, 9, 16, 36, 64, 144$ nodes.
685
686  
687  
688 \begin{table}[htb]
689   \caption{Running NAS benchmarks on 4 nodes }
690   % title of Table
691   \centering
692   \begin{tabular}{|*{7}{l|}}
693     \hline
694     Method     & Execution     & Energy         & Energy      & Performance        & Distance      \\
695     name       & time/s        & consumption/J  & saving\%    & degradation\%      &               \\
696     \hline
697     CG         &  64.64        & 3560.39        &34.16        &6.72               &27.44       \\
698     \hline 
699     MG         & 18.89         & 1074.87            &35.37            &4.34                   &31.03       \\
700    \hline
701     EP         &79.73          &5521.04         &26.83            &3.04               &23.79      \\
702    \hline
703     LU         &308.65         &21126.00           &34.00             &6.16                   &27.84      \\
704     \hline
705     BT         &360.12         &21505.55           &35.36         &8.49               &26.87     \\
706    \hline
707     SP         &234.24         &13572.16           &35.22         &5.70               &29.52    \\
708    \hline
709     FT         &81.58          &4151.48        &35.58         &0.99                   &34.59    \\
710 \hline 
711   \end{tabular}
712   \label{table:res_4n}
713 \end{table}
714
715 \begin{table}[htb]
716   \caption{Running NAS benchmarks on 8 and 9 nodes }
717   % title of Table
718   \centering
719   \begin{tabular}{|*{7}{l|}}
720     \hline
721     Method     & Execution     & Energy         & Energy      & Performance        & Distance      \\
722     name       & time/s        & consumption/J  & saving\%    & degradation\%      &               \\
723     \hline
724     CG         &36.11              &3263.49             &31.25        &7.12                    &24.13     \\
725     \hline 
726     MG         &8.99           &953.39          &33.78        &6.41                    &27.37     \\
727    \hline
728     EP         &40.39          &5652.81         &27.04        &0.49                    &26.55     \\
729    \hline
730     LU         &218.79             &36149.77        &28.23        &0.01                    &28.22      \\
731     \hline
732     BT         &166.89         &23207.42            &32.32            &7.89                    &24.43      \\
733    \hline
734     SP         &104.73         &18414.62            &24.73            &2.78                    &21.95      \\
735    \hline
736     FT         &51.10          &4913.26         &31.02        &2.54                    &28.48      \\
737 \hline 
738   \end{tabular}
739   \label{table:res_8n}
740 \end{table}
741
742 \begin{table}[htb]
743   \caption{Running NAS benchmarks on 16 nodes }
744   % title of Table
745   \centering
746   \begin{tabular}{|*{7}{l|}}
747     \hline
748     Method     & Execution     & Energy         & Energy      & Performance        & Distance      \\
749     name       & time/s        & consumption/J  & saving\%    & degradation\%      &               \\
750     \hline
751     CG         &31.74          &4373.90         &26.29        &9.57                    &16.72          \\
752     \hline 
753     MG         &5.71           &1076.19         &32.49        &6.05                    &26.44         \\
754    \hline
755     EP         &20.11          &5638.49         &26.85        &0.56                    &26.29         \\
756    \hline
757     LU         &144.13         &42529.06            &28.80            &6.56                    &22.24         \\
758     \hline
759     BT         &97.29          &22813.86            &34.95        &5.80                &29.15         \\
760    \hline
761     SP         &66.49          &20821.67            &22.49            &3.82                    &18.67         \\
762    \hline
763     FT             &37.01          &5505.60             &31.59        &6.48                    &25.11         \\
764 \hline 
765   \end{tabular}
766   \label{table:res_16n}
767 \end{table}
768
769 \begin{table}[htb]
770   \caption{Running NAS benchmarks on 32 and 36 nodes }
771   % title of Table
772   \centering
773   \begin{tabular}{|*{7}{l|}}
774     \hline
775     Method     & Execution     & Energy         & Energy      & Performance        & Distance      \\
776     name       & time/s        & consumption/J  & saving\%    & degradation\%      &               \\
777     \hline
778     CG         &32.35          &6704.21         &16.15        &5.30                    &10.85           \\
779     \hline 
780     MG         &4.30           &1355.58         &28.93        &8.85                    &20.08          \\
781    \hline
782     EP         &9.96           &5519.68         &26.98        &0.02                    &26.96          \\
783    \hline
784     LU         &99.93          &67463.43            &23.60            &2.45                    &21.15          \\
785     \hline
786     BT         &48.61          &23796.97            &34.62            &5.83                    &28.79          \\
787    \hline
788     SP         &46.01          &27007.43            &22.72            &3.45                    &19.27           \\
789    \hline
790     FT             &28.06          &7142.69             &23.09        &2.90                    &20.19           \\
791 \hline 
792   \end{tabular}
793   \label{table:res_32n}
794 \end{table}
795
796 \begin{table}[htb]
797   \caption{Running NAS benchmarks on 64 nodes }
798   % title of Table
799   \centering
800   \begin{tabular}{|*{7}{l|}}
801     \hline
802     Method     & Execution     & Energy         & Energy      & Performance        & Distance      \\
803     name       & time/s        & consumption/J  & saving\%    & degradation\%      &               \\
804     \hline
805     CG         &46.65          &17521.83            &8.13             &1.68                    &6.45           \\
806     \hline 
807     MG         &3.27           &1534.70         &29.27        &14.35               &14.92          \\
808    \hline
809     EP         &5.05           &5471.1084           &27.12            &3.11                &24.01         \\
810    \hline
811     LU         &73.92          &101339.16           &21.96            &3.67                    &18.29         \\
812     \hline
813     BT         &39.99          &27166.71            &32.02            &12.28               &19.74         \\
814    \hline
815     SP         &52.00          &49099.28            &24.84            &0.03                    &24.81         \\
816    \hline
817     FT         &25.97          &10416.82        &20.15        &4.87                    &15.28         \\
818 \hline 
819   \end{tabular}
820   \label{table:res_64n}
821 \end{table}
822
823
824 \begin{table}[htb]
825   \caption{Running NAS benchmarks on 128 and 144 nodes }
826   % title of Table
827   \centering
828   \begin{tabular}{|*{7}{l|}}
829     \hline
830     Method     & Execution     & Energy         & Energy      & Performance        & Distance     \\
831     name       & time/s        & consumption/J  & saving\%    & degradation\%      &              \\
832     \hline
833     CG         &56.92          &41163.36        &4.00         &1.10                    &2.90          \\
834     \hline 
835     MG         &3.55           &2843.33         &18.77        &10.38               &8.39          \\
836    \hline
837     EP         &2.67           &5669.66         &27.09        &0.03                    &27.06         \\
838    \hline
839     LU         &51.23          &144471.90       &16.67        &2.36                    &14.31         \\
840     \hline
841     BT         &37.96          &44243.82            &23.18            &1.28                    &21.90         \\
842    \hline
843     SP         &64.53          &115409.71           &26.72            &0.05                    &26.67         \\
844    \hline
845     FT         &25.51          &18808.72            &12.85            &2.84                    &10.01         \\
846 \hline 
847   \end{tabular}
848   \label{table:res_128n}
849 \end{table}
850 The overall energy consumption was computed for each instance according to the energy 
851 consumption  model EQ(\ref{eq:energy}), with and without applying the algorithm. The 
852 execution time was also measured for all these experiments. Then, the energy saving 
853 and performance degradation percentages were computed for each instance.  
854 The results are presented in tables (\ref{table:res_4n}, \ref{table:res_8n}, \ref{table:res_16n}, 
855 \ref{table:res_32n}, \ref{table:res_64n} and \ref{table:res_128n}). All these results are the 
856 average values from many experiments for  energy savings and performance degradation.
857
858 The tables  show the experimental results for running the NAS parallel benchmarks on different 
859 number of nodes. The experiments show that the algorithm reduce significantly the energy 
860 consumption (up to 35\%) and tries to limit the performance degradation. They also show that 
861 the  energy saving percentage is decreased  when the number of the computing nodes is increased. 
862 This reduction is due to the increase of the communication times compared to the execution times 
863 when the benchmarks are run over a high number of nodes. Indeed, the benchmarks with the same class, C, 
864 are executed on different number of nodes, so the computation required for each iteration is divided 
865 by the number of computing nodes.   On the other hand, more communications are required when increasing 
866 the number of nodes so the static energy is increased linearly according to the communication time and 
867 the dynamic power is less relevant in the overall energy consumption. Therefore, reducing the frequency 
868 with algorithm~(\ref{HSA}) have less effect in reducing the overall energy savings. It can also be 
869 noticed that for the benchmarks EP and SP that contain little or no communications,  the energy savings 
870 are not significantly affected with the high number of nodes. No experiments were conducted using bigger 
871 classes such as D, because they require a lot of memory(more than 64GB) when being executed by the simulator 
872 on one machine. The maximum distance between the normalized energy curve and the normalized performance 
873 for each instance is also shown in the result tables. It is decreased in the same way as the energy 
874 saving percentage. The tables also show that the performance degradation percentage is not significantly 
875 increased when the number of computing nodes is increased because the computation times are small when 
876 compared to the communication times.  
877
878
879  
880 \begin{figure}
881   \centering
882   \subfloat[Energy saving]{%
883     \includegraphics[width=.2315\textwidth]{fig/energy}\label{fig:energy}}%
884   \quad%
885   \subfloat[Performance degradation ]{%
886     \includegraphics[width=.2315\textwidth]{fig/per_deg}\label{fig:per_deg}}
887   \label{fig:avg}
888   \caption{The energy and performance for all NAS benchmarks running with difference number of nodes}
889 \end{figure}
890
891 Plots (\ref{fig:energy} and \ref{fig:per_deg}) present the energy saving and performance degradation 
892 respectively for all the benchmarks according to the number of used nodes. As shown in the first plot, 
893 the energy saving percentages of the benchmarks MG, LU, BT and FT are decreased linearly  when the the 
894 number of nodes is increased. While for the  EP and SP benchmarks, the energy saving percentage is not 
895 affected by the increase of the number of computing nodes, because in these benchmarks there are little or 
896 no communications. Finally, the energy saving of the GC benchmark  is significantly decreased when the number 
897 of nodes is increased because  this benchmark has more communications than the others. The second plot 
898 shows that the performance degradation percentages of most of the benchmarks are decreased when they 
899 run on a big number of nodes because they spend more time communicating than computing, thus, scaling 
900 down the frequencies of some nodes have less effect on the performance. 
901
902
903
904
905 \subsection{The results for different power consumption scenarios}
906
907 The results of the previous section were obtained while using processors that consume during computation 
908 an overall power which is 80\% composed of  dynamic power and 20\% of static power. In this section, 
909 these ratios are changed and two new power scenarios are considered in order to evaluate how the proposed  
910 algorithm adapts itself according to the static and dynamic power values.  The two new power scenarios 
911 are the following: 
912
913 \begin{itemize}
914 \item 70\% dynamic power  and 30\% static power
915 \item 90\% dynamic power  and 10\% static power
916 \end{itemize}
917
918 The NAS parallel benchmarks were executed again over processors that follow the the new power scenarios. 
919 The class C of each benchmark was run over 8 or 9 nodes and the results are presented in  tables 
920 (\ref{table:res_s1} and \ref{table:res_s2}). These tables show that the energy saving percentage of the 70\%-30\% 
921 scenario is less for all benchmarks compared to the energy saving of the 90\%-10\% scenario. Indeed, in the latter 
922 more dynamic power is consumed when nodes are running on their maximum frequencies, thus, scaling down the frequency 
923 of the nodes results in higher energy savings than in the 70\%-30\% scenario. On the other hand,  the performance 
924 degradation percentage is less in the 70\%-30\% scenario  compared to the 90\%-10\%  scenario. This is due to the 
925 higher static power percentage in the first scenario which makes it more relevant in the overall consumed energy. 
926 Indeed, the static energy is related to the execution time and if the performance is  degraded the total consumed 
927 static energy is directly increased. Therefore, the proposed algorithm do not scales down much the frequencies of the 
928 nodes  in order to limit the increase of the execution time and thus limiting the effect of the consumed static energy .
929
930 The two new power scenarios are compared to the old one in figure (\ref{fig:sen_comp}). It shows the average of 
931 the performance degradation, the energy saving and the distances for all NAS benchmarks of class C running on 8 or 9 nodes. 
932 The comparison shows that  the energy saving ratio is proportional to the dynamic power ratio: it is increased 
933 when applying the  90\%-10\% scenario because at maximum frequency the dynamic  energy is the the most relevant 
934 in the overall consumed energy and can be reduced by lowering the frequency of some processors. On the other hand, 
935 the energy saving is decreased when  the 70\%-30\% scenario is used because the dynamic  energy is less relevant in 
936 the overall consumed energy and lowering the frequency do not returns big energy savings.
937 Moreover, the average of the performance degradation is decreased when using a higher ratio for static power 
938 (e.g. 70\%-30\% scenario and 80\%-20\% scenario). Since the proposed algorithm optimizes the energy consumption 
939 when using a higher ratio for dynamic power the algorithm selects bigger frequency scaling factors that result in 
940 more energy saving but less performance, for example see the figure (\ref{fig:scales_comp}). The opposite happens 
941 when using a higher ratio for  static  power, the algorithm proportionally  selects  smaller scaling values which 
942 results in less energy saving but less performance degradation. 
943
944
945  \begin{table}[htb]
946   \caption{The results of 70\%-30\% powers scenario}
947   % title of Table
948   \centering
949   \begin{tabular}{|*{6}{l|}}
950     \hline
951     Method     & Energy          & Energy      & Performance        & Distance     \\
952     name       & consumption/J   & saving\%    & degradation\%      &              \\
953     \hline
954     CG         &4144.21          &22.42        &7.72                &14.70         \\
955     \hline 
956     MG         &1133.23          &24.50        &5.34                &19.16          \\
957    \hline
958     EP         &6170.30         &16.19         &0.02                &16.17          \\
959    \hline
960     LU         &39477.28        &20.43         &0.07                &20.36          \\
961     \hline
962     BT         &26169.55            &25.34             &6.62                &18.71          \\
963    \hline
964     SP         &19620.09            &19.32             &3.66                &15.66          \\
965    \hline
966     FT         &6094.07         &23.17         &0.36                &22.81          \\
967 \hline 
968   \end{tabular}
969   \label{table:res_s1}
970 \end{table}
971
972
973
974 \begin{table}[htb]
975   \caption{The results of 90\%-10\% powers scenario}
976   % title of Table
977   \centering
978   \begin{tabular}{|*{6}{l|}}
979     \hline
980     Method     & Energy          & Energy      & Performance        & Distance     \\
981     name       & consumption/J   & saving\%    & degradation\%      &              \\
982     \hline
983     CG         &2812.38          &36.36        &6.80                &29.56         \\
984     \hline 
985     MG         &825.427          &38.35        &6.41                &31.94         \\
986    \hline
987     EP         &5281.62          &35.02        &2.68                &32.34         \\
988    \hline
989     LU         &31611.28             &39.15        &3.51                    &35.64        \\
990     \hline
991     BT         &21296.46             &36.70            &6.60                &30.10       \\
992    \hline
993     SP         &15183.42             &35.19            &11.76               &23.43        \\
994    \hline
995     FT         &3856.54          &40.80        &5.67                &35.13        \\
996 \hline 
997   \end{tabular}
998   \label{table:res_s2}
999 \end{table}
1000
1001
1002 \begin{figure}
1003   \centering
1004   \subfloat[Comparison the average of the results on 8 nodes]{%
1005     \includegraphics[width=.22\textwidth]{fig/sen_comp}\label{fig:sen_comp}}%
1006   \quad%
1007   \subfloat[Comparison the selected frequency scaling factors of MG benchmark class C running on 8 nodes]{%
1008     \includegraphics[width=.24\textwidth]{fig/three_scenarios}\label{fig:scales_comp}}
1009   \label{fig:comp}
1010   \caption{The comparison of the three power scenarios}
1011 \end{figure}  
1012
1013
1014
1015 \subsection{The verifications of the proposed method}
1016 \label{sec.verif}
1017 The precision of the proposed algorithm mainly depends on the execution time prediction model defined in 
1018 EQ(\ref{eq:perf}) and the energy model computed by EQ(\ref{eq:energy}). 
1019 The energy model is also significantly dependent  on the execution time model because the static energy is 
1020 linearly related the execution time and the dynamic energy is related to the computation time. So, all of 
1021 the work presented in this paper is based on the execution time model. To verify this model, the predicted 
1022 execution time was compared to  the real execution time over Simgrid for all  the NAS parallel benchmarks 
1023 running class B on 8 or 9 nodes. The comparison showed that the proposed execution time model is very precise, 
1024 the maximum normalized difference between  the predicted execution time  and the real execution time is equal 
1025 to 0.03 for all the NAS benchmarks.
1026
1027 Since  the proposed algorithm is not an exact method and do not test all the possible solutions (vectors of scaling factors) 
1028 in the search space and to prove its efficiency, it was compared on small instances to a brute force search algorithm 
1029 that tests all the possible solutions. The brute force algorithm was applied to different NAS benchmarks classes with 
1030 different number of nodes. The solutions returned by the brute force algorithm and the proposed algorithm were identical 
1031 and the proposed algorithm was on average 10 times faster than the brute force algorithm. It has a small execution time: 
1032 for a heterogeneous cluster composed of four different types of nodes having the characteristics presented in 
1033 table~(\ref{table:platform}), it takes on average \np[ms]{0.04}  for 4 nodes and \np[ms]{0.15} on average for 144 nodes 
1034 to compute the best scaling factors vector.  The algorithm complexity is $O(F\cdot (N \cdot4) )$, where $F$ is the number 
1035 of iterations and $N$ is the number of computing nodes. The algorithm needs  from 12 to 20 iterations to select the best 
1036 vector of frequency scaling factors that gives the results of the section (\ref{sec.res}).
1037
1038 \section{Conclusion}
1039 \label{sec.concl}
1040
1041
1042 \section*{Acknowledgment}
1043
1044
1045 % trigger a \newpage just before the given reference
1046 % number - used to balance the columns on the last page
1047 % adjust value as needed - may need to be readjusted if
1048 % the document is modified later
1049 %\IEEEtriggeratref{15}
1050
1051 \bibliographystyle{IEEEtran}
1052 \bibliography{IEEEabrv,my_reference}
1053 \end{document}
1054
1055 %%% Local Variables:
1056 %%% mode: latex
1057 %%% TeX-master: t
1058 %%% fill-column: 80
1059 %%% ispell-local-dictionary: "american"
1060 %%% End:
1061
1062 % LocalWords:  Fanfakh Charr FIXME Tianhe DVFS HPC NAS NPB SMPI Rauber's Rauber
1063 % LocalWords:  CMOS EQ EPSA Franche Comté Tflop Rünger IUT Maréchal Juin cedex
1064 % LocalWords:  de badri muslim MPI TcpOld TcmOld dNew dOld cp Sopt Tcp Tcm Ps
1065 % LocalWords:  Scp Fmax Fdiff SimGrid GFlops Xeon EP BT